{"id":459543,"date":"2024-10-20T10:04:36","date_gmt":"2024-10-20T10:04:36","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/aecdaily-td-en-133702-1023\/"},"modified":"2024-10-26T18:37:40","modified_gmt":"2024-10-26T18:37:40","slug":"aecdaily-td-en-133702-1023","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/aecdaily\/aecdaily-td-en-133702-1023\/","title":{"rendered":"AECDAILY TD EN 133702 1023"},"content":{"rendered":"
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | Slide 1 <\/td>\n<\/tr>\n | ||||||
2<\/td>\n | Slide 2: Smoke Containment Strategies for Elevator Hoistways and Lobbies <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | Slide 3 <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | Slide 4: How to Use This Online Learning Course <\/td>\n<\/tr>\n | ||||||
5<\/td>\n | Slide 5: Purpose and Learning Objectives <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | Slide 6: Contents <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | Slide 7: Fire and Smoke Behavior in High-Rise Buildings <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | Slide 8: Fires in High-Rise Buildings <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | Slide 9: Fire Protection in High-Rise Buildings <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | Slide 10: Smoke Hazards in High-Rise Building Fires <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | Slide 11: Smoke Hazards in High-Rise Building Fires <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | Slide 12: Stack Effect <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | Slide 13: Smoke in Stairwells and Elevator Shafts <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | Slide 14: Smoke in Stairwells and Elevator Shafts <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | Slide 15: Gap between the Elevator Door and Frame <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | Slide 16: Impact of Occupant Response and Behavior <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | Slide 17: Actual Evacuation Time <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | Slide 18: Case Study: MGM Grand Hotel and Casino <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | Slide 19: Case Study: MGM Grand Hotel and Casino <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | Slide 20: Case Study: MGM Grand Hotel and Casino <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | Slide 21 <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | Slide 22 <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | Slide 23: Building Codes and Smoke Containment <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | Slide 24: Active vs. Passive Fire Protection <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | Slide 25: Smoke Containment <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | Slide 26: Enclosed Elevator Lobby Requirements <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | Slide 27: Enclosed Elevator Lobby Requirements <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | Slide 28: Enclosed Elevator Lobby: Exceptions <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | Slide 29: Enclosed Elevator Lobby: Exceptions <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | Slide 30: Enclosed Elevator Lobby: Exceptions <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | Slide 31: Enclosed Elevator Lobby: Exceptions <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | Slide 32: Enclosed Elevator Lobby: Exceptions <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | Slide 33: Enclosed Elevator Lobby: Exceptions <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | Slide 34: Corridor Continuity <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | Slide 35: Methods of Protection <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | Slide 36: Questions about Enclosed Elevator Lobbies <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | Slide 37: Questions about Enclosed Elevator Lobbies <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | Slide 38 <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | Slide 39 <\/td>\n<\/tr>\n | ||||||
40<\/td>\n | Slide 40: Smoke and Draft Control Doors <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | Slide 41: Alternatives to Enclosed Elevator Lobbies <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | Slide 42: Fire-Rated Doors <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | Slide 43: Smoke and Draft Control Doors <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | Slide 44: Smoke and Draft Control Doors <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | Slide 45: Fire- and Smoke-Rated Door Locations <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | Slide 46: Requirements for a Smoke and Draft Control Door <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | Slide 47: ASME A17.1 Safety Code for Elevators and Escalators <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | Slide 48: How Is a Smoke and Draft Door Assembly Achieved? <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | Slide 49: Smoke Curtains <\/td>\n<\/tr>\n | ||||||
50<\/td>\n | Slide 50: Smoke Curtains <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | Slide 51: Accordion Fire Doors <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | Slide 52: Swing Door Assemblies <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | Slide 53: Compliant or Not? <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | Slide 54: Compliant or Not? <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | Slide 55: Compliant or Not? <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | Slide 56: Compliant or Not? <\/td>\n<\/tr>\n | ||||||
57<\/td>\n | Slide 57 <\/td>\n<\/tr>\n | ||||||
58<\/td>\n | Slide 58 <\/td>\n<\/tr>\n | ||||||
59<\/td>\n | Slide 59: Egress through Intervening Spaces <\/td>\n<\/tr>\n | ||||||
60<\/td>\n | Slide 60: Egress through Intervening Spaces <\/td>\n<\/tr>\n | ||||||
61<\/td>\n | Slide 61: Egress through Intervening Spaces <\/td>\n<\/tr>\n | ||||||
62<\/td>\n | Slide 62: Fire Service Access Elevator Lobbies <\/td>\n<\/tr>\n | ||||||
63<\/td>\n | Slide 63: Example: Fire Access Elevator Lobby <\/td>\n<\/tr>\n | ||||||
64<\/td>\n | Slide 64: Occupant Evacuation Elevator Lobbies <\/td>\n<\/tr>\n | ||||||
65<\/td>\n | Slide 65: Occupant Evacuation Elevator Lobbies <\/td>\n<\/tr>\n | ||||||
66<\/td>\n | Slide 66: Resources <\/td>\n<\/tr>\n | ||||||
67<\/td>\n | Slide 67: Resources <\/td>\n<\/tr>\n | ||||||
68<\/td>\n | Slide 68: Thank You <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Smoke Containment Strategies for Elevator Hoistways and Lobbies<\/b><\/p>\n |