{"id":314301,"date":"2024-10-19T21:38:47","date_gmt":"2024-10-19T21:38:47","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-iso-4266-12002\/"},"modified":"2024-10-25T19:45:22","modified_gmt":"2024-10-25T19:45:22","slug":"bs-iso-4266-12002","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-iso-4266-12002\/","title":{"rendered":"BS ISO 4266-1:2002"},"content":{"rendered":"

This part of ISO 4266 gives guidance on the accuracy, installation, commissioning, calibration and verification of automatic level gauges (ALGs), of both intrusive and non-intrusive types, for measuring the level of petroleum and petroleum products having a Reid vapour pressure less than 100 kPa, stored in atmospheric storage tanks.<\/p>\n

This part of ISO 4266 is not applicable to the measurement of level in refrigerated storage tanks with ALG equipment.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
3<\/td>\nTitlePage – Petroleum and liquid petroleum products\ufffd\u2014 Measurement of level and temperature in sto… <\/td>\n<\/tr>\n
5<\/td>\nTableofContent – Contents Page <\/td>\n<\/tr>\n
7<\/td>\nForeword – Foreword <\/td>\n<\/tr>\n
9<\/td>\nScope – 1\ufffd\ufffd\ufffd Scope
NormativeReference – 2\ufffd\ufffd\ufffd Normative references <\/td>\n<\/tr>\n
11<\/td>\nClause1 – 4\ufffd\ufffd\ufffd Precautions
Subclause2 – 4.1\ufffd\ufffd\ufffd Safety precautions
Subclause2 – 4.2\ufffd\ufffd\ufffd Equipment precautions
UntitledSubclause3 – 4.2.1\ufffd\ufffd\ufffd All of the ALG equipment should be capable of withstanding the pres…
UntitledSubclause3 – 4.2.2\ufffd\ufffd\ufffd ALGs should be certified for use in the hazardous-area classificati…
UntitledSubclause3 – 4.2.3\ufffd\ufffd\ufffd Measures should be taken to ensure that all exposed metal parts of …
UntitledSubclause3 – 4.2.4\ufffd\ufffd\ufffd All ALG equipment should be maintained in safe operating condition …
Subclause2 – 4.3\ufffd\ufffd\ufffd General precautions
UntitledSubclause3 – 4.3.1\ufffd\ufffd\ufffd The general precautions given in
UntitledSubclause3 – 4.3.2\ufffd\ufffd\ufffd Tank temperatures should be measured at the same time as the tank l…
UntitledSubclause3 – 4.3.3\ufffd\ufffd\ufffd Levels measured for bulk transfer should be recorded promptly when …
UntitledSubclause3 – 4.3.4\ufffd\ufffd\ufffd Whenever determinations of the contents of a tank are made before t…
UntitledSubclause3 – 4.3.5\ufffd\ufffd\ufffd All parts of the ALG in contact with the product or its vapour shou…
UntitledSubclause3 – 4.3.6\ufffd\ufffd\ufffd ALGs should have sufficient dynamic response to track the liquid le…
UntitledSubclause3 – 4.3.7\ufffd\ufffd\ufffd Following the transfer of product, the tank should be allowed to se…
UntitledSubclause3 – 4.3.8\ufffd\ufffd\ufffd ALGs should provide security to prevent unauthorized adjustment or … <\/td>\n<\/tr>\n
12<\/td>\nClause1 – 5\ufffd\ufffd\ufffd Accuracy
Subclause2 – 5.1\ufffd\ufffd\ufffd Intrinsic error of ALGs
Subclause2 – 5.2\ufffd\ufffd\ufffd Calibration prior to installation
Subclause2 – 5.3\ufffd\ufffd\ufffd Error caused by installation and operating conditions
Subclause2 – 5.4\ufffd\ufffd\ufffd Overall accuracy
Subclause3 – 5.4.1\ufffd\ufffd\ufffd General <\/td>\n<\/tr>\n
13<\/td>\nSubclause3 – 5.4.2\ufffd\ufffd\ufffd Use of ALGs for fiscal\ufffd\/custody transfer purposes
Clause1 – 6\ufffd\ufffd\ufffd Installation of ALGs
Subclause2 – 6.1\ufffd\ufffd\ufffd General
Subclause2 – 6.2\ufffd\ufffd\ufffd Mounting location
Subclause2 – 6.3\ufffd\ufffd\ufffd Manufacturer’s requirements
Subclause2 – 6.4\ufffd\ufffd\ufffd Installation
UntitledSubclause3 – 6.4.1\ufffd\ufffd\ufffd For fiscal\/custody transfer accuracy, an ullage ALG should be mount…
UntitledSubclause3 – 6.4.2\ufffd\ufffd\ufffd As an alternative, an ullage-based ALG may be mounted on the roof o…
UntitledSubclause3 – 6.4.3\ufffd\ufffd\ufffd Innage-based ALGs should be mounted at a stable location at the tan…
UntitledSubclause3 – 6.4.4\ufffd\ufffd\ufffd Where possible, the ALG should be located in close proximity to the… <\/td>\n<\/tr>\n
19<\/td>\nSubclause2 – 6.5\ufffd\ufffd\ufffd Still-well design
UntitledSubclause3 – 6.5.1\ufffd\ufffd\ufffd The still-well should be attached in either of the two ways describ…
UntitledSubclause3 – 6.5.2\ufffd\ufffd\ufffd The still-well may be supported on the bottom of the tank.
UntitledSubclause3 – 6.5.3\ufffd\ufffd\ufffd The still-well may be supported by a trunnion or hinge connected to…
UntitledSubclause3 – 6.5.4\ufffd\ufffd\ufffd The upper end of the still-well and the sliding guide should be des…
UntitledSubclause3 – 6.5.5\ufffd\ufffd\ufffd The recommended minimum still-well diameter is
UntitledSubclause3 – 6.5.6\ufffd\ufffd\ufffd The distance from the bottom of the still-well to the bottom of the…
UntitledSubclause3 – 6.5.7\ufffd\ufffd\ufffd The still-well should be perforated with one or two rows of slots o…
UntitledSubclause3 – 6.5.8\ufffd\ufffd\ufffd After the tank has been hydrostatically tested, the still-well shou…
Clause1 – 7\ufffd\ufffd\ufffd Initial setting and initial verification of ALGs in the field
Subclause2 – 7.1\ufffd\ufffd\ufffd Introduction <\/td>\n<\/tr>\n
20<\/td>\nSubclause2 – 7.2\ufffd\ufffd\ufffd General precautions
Subclause3 – 7.2.1\ufffd\ufffd\ufffd Initial requirements
Subclause3 – 7.2.2\ufffd\ufffd\ufffd Manual reference level measurement procedure
Subclause3 – 7.2.3\ufffd\ufffd\ufffd Reference measurement tape and weight certification
Subclause3 – 7.2.4\ufffd\ufffd\ufffd Effect of weather
Subclause3 – 7.2.5\ufffd\ufffd\ufffd ALG technology-specific considerations
Subclause3 – 7.2.6\ufffd\ufffd\ufffd Application-specific considerations <\/td>\n<\/tr>\n
21<\/td>\nSubclause2 – 7.3\ufffd\ufffd\ufffd Initial settings of ALGs
Subclause3 – 7.3.1\ufffd\ufffd\ufffd Setting against manual reference ullage measurements
Subclause3 – 7.3.2\ufffd\ufffd\ufffd Setting against manual reference dip (innage) measurements <\/td>\n<\/tr>\n
22<\/td>\nSubclause2 – 7.4\ufffd\ufffd\ufffd Initial verification
Subclause3 – 7.4.1\ufffd\ufffd\ufffd Introduction <\/td>\n<\/tr>\n
23<\/td>\nSubclause3 – 7.4.2\ufffd\ufffd\ufffd Verification conditions
Subclause3 – 7.4.3\ufffd\ufffd\ufffd Initial verification procedures
Subclause4 – 7.4.3.1\ufffd\ufffd\ufffd ALG verification by manual reference ullage (outage) measurements <\/td>\n<\/tr>\n
24<\/td>\nSubclause4 – 7.4.3.2\ufffd\ufffd\ufffd ALG verification by manual reference dip (innage) measurements
Subclause4 – 7.4.3.3\ufffd\ufffd\ufffd Verification tolerance for ALGs in fiscal\/custody transfer application
Subclause2 – 7.5\ufffd\ufffd\ufffd Record keeping <\/td>\n<\/tr>\n
25<\/td>\nClause1 – 8\ufffd\ufffd\ufffd Subsequent verification of ALGs
Subclause2 – 8.1\ufffd\ufffd\ufffd General
Subclause2 – 8.2\ufffd\ufffd\ufffd Frequency of subsequent verification
Subclause2 – 8.3\ufffd\ufffd\ufffd Procedure for subsequent verification
Subclause2 – 8.4\ufffd\ufffd\ufffd Tolerance for subsequent verification
Clause1 – 9\ufffd\ufffd\ufffd Data communication and receiving <\/td>\n<\/tr>\n
26<\/td>\nBibliography – Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Petroleum and liquid petroleum products. Measurement of level and temperature in storage tanks by automatic methods – Measurement of level in atmospheric tanks<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2002<\/td>\n28<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":314309,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[1081,2641],"product_tag":[],"class_list":{"0":"post-314301","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-75-180-30","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/314301","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/314309"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=314301"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=314301"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=314301"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}