{"id":26063,"date":"2024-10-17T02:26:36","date_gmt":"2024-10-17T02:26:36","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/oh-mechanicalcode-07-2007\/"},"modified":"2024-10-24T13:44:11","modified_gmt":"2024-10-24T13:44:11","slug":"oh-mechanicalcode-07-2007","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/oh\/oh-mechanicalcode-07-2007\/","title":{"rendered":"OH MechanicalCode 07 2007"},"content":{"rendered":"

 This publication contains the Ohio Mechanical Code and the Ohio Boiler and Pressure Vessel Rules. The Ohio Mechanical Code is based on the 2006 International Mechanical Code\u00ae.<\/span><\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nTITLE PAGE <\/td>\n<\/tr>\n
2<\/td>\nCOPYRIGHT <\/td>\n<\/tr>\n
3<\/td>\nPREFACE <\/td>\n<\/tr>\n
5<\/td>\nTABLE OF CONTENTS <\/td>\n<\/tr>\n
9<\/td>\nCHAPTER 1 ADMINISTRATION
SECTION 101 GENERAL
CHAPTER 1 OF THE 2007 OHIO BUILDING CODE USE AS REFERENCE FOR THIS CODE ONLY (PROVIDED AS A CONVENIENCE FOR CODE USERS)
SECTION 101 GENERAL <\/td>\n<\/tr>\n
10<\/td>\nSECTION 102 APPLICABILITY <\/td>\n<\/tr>\n
11<\/td>\nSECTION 103 CERTIFIED BUILDING DEPARTMENTS AND PERSONNEL <\/td>\n<\/tr>\n
20<\/td>\nSECTION 104 DUTIES AND POWERS <\/td>\n<\/tr>\n
21<\/td>\nSECTION 105 APPROVALS <\/td>\n<\/tr>\n
24<\/td>\nSECTION 106 CONSTRUCTION DOCUMENTS <\/td>\n<\/tr>\n
27<\/td>\nSECTION 107 TEMPORARY STRUCTURES AND OCCUPANCIES
SECTION 108 CONSTRUCTION DOCUMENTS, EXAMINATION AND INSPECTION FEES
TABLE 108.2 <\/td>\n<\/tr>\n
28<\/td>\nSECTION 109 INSPECTIONS AND TESTING <\/td>\n<\/tr>\n
30<\/td>\nSECTION 110 CERTIFICATE OF OCCUPANCY <\/td>\n<\/tr>\n
31<\/td>\nSECTION 111 SERVICE UTILITIES
SECTION 112 BOARD OF APPEALS <\/td>\n<\/tr>\n
33<\/td>\nSECTION 113 VIOLATIONS
SECTION 114 STOP WORK ORDER <\/td>\n<\/tr>\n
34<\/td>\nSECTION 115 UNSAFE BUILDINGS
SECTION 116 CHANGES TO THE CODE
SECTION 117 INDUSTRIALIZED UNITS <\/td>\n<\/tr>\n
36<\/td>\nSECTION 118 PRODUCTS AND MATERIALS <\/td>\n<\/tr>\n
38<\/td>\nTABLE 118.3
SECTION 119 APPROVED AGENCIES <\/td>\n<\/tr>\n
39<\/td>\nCHAPTER 2 DEFINITIONS
SECTION 201 GENERAL
SECTION 202 GENERAL DEFINITIONS <\/td>\n<\/tr>\n
51<\/td>\nCHAPTER 3 GENERAL REGULATIONS
SECTION 301 GENERAL <\/td>\n<\/tr>\n
52<\/td>\nSECTION 302 PROTECTION OF STRUCTURE <\/td>\n<\/tr>\n
53<\/td>\nSECTION 303 EQUIPMENT AND APPLIANCE LOCATION
SECTION 304 INSTALLATION <\/td>\n<\/tr>\n
54<\/td>\nSECTION 305 PIPING SUPPORT <\/td>\n<\/tr>\n
55<\/td>\nTABLE 305.4 PIPING SUPPORT SPACINGa
SECTION 306 ACCESS AND SERVICE SPACE <\/td>\n<\/tr>\n
56<\/td>\nSECTION 307 CONDENSATE DISPOSAL <\/td>\n<\/tr>\n
57<\/td>\nSECTION 308 CLEARANCE REDUCTION <\/td>\n<\/tr>\n
58<\/td>\nTABLE 308.6 CLEARANCE REDUCTION METHODS
SECTION 309 TEMPERATURE CONTROL <\/td>\n<\/tr>\n
59<\/td>\nSECTION 310 EXPLOSION CONTROL
SECTION 311 SMOKE AND HEAT VENTS
SECTION 312 HEATING AND COOLING LOAD CALCULATIONS
SECTION 313 WELDING AND BRAZING <\/td>\n<\/tr>\n
61<\/td>\nCHAPTER 4 VENTILATION
SECTION 401 GENERAL
TABLE 401.5 OPENING SIZES IN LOUVERS, GRILLES AND SCREENS PROTECTING OUTDOOR EXHAUST AND AIR INTAKE OPENINGS
SECTION 402 NATURAL VENTILATION <\/td>\n<\/tr>\n
62<\/td>\nSECTION 403 MECHANICAL VENTILATION
(Equation 4-1) <\/td>\n<\/tr>\n
63<\/td>\nTABLE 403.3 REQUIRED OUTDOOR VENTILATION AIR
SECTION 404 ENCLOSED PARKING GARAGES
SECTION 405 SYSTEMS CONTROL
SECTION 406 VENTILATION OF UNINHABITED SPACES <\/td>\n<\/tr>\n
64<\/td>\nTABLE 403.3\u2014continued
TABLE 403.3\u2014continued <\/td>\n<\/tr>\n
67<\/td>\nCHAPTER 5 EXHAUST SYSTEMS
SECTION 501 GENERAL
SECTION 502 REQUIRED SYSTEMS <\/td>\n<\/tr>\n
68<\/td>\n(Equation 5-1) <\/td>\n<\/tr>\n
74<\/td>\nSECTION 503 MOTORS AND FANS
SECTION 504 CLOTHES DRYER EXHAUST <\/td>\n<\/tr>\n
75<\/td>\nSECTION 505 DOMESTIC KITCHEN EXHAUST EQUIPMENT
SECTION 506 COMMERCIAL KITCHEN HOOD VENTILATION SYSTEM DUCTS AND EXHAUST EQUIPMENT <\/td>\n<\/tr>\n
78<\/td>\nSECTION 507 COMMERCIAL KITCHEN HOODS <\/td>\n<\/tr>\n
80<\/td>\nTABLE 507.11 MINIMUM DISTANCE BETWEEN THE LOWEST EDGE OF A GREASE FILTER AND THE COOKING SURFACE OR THE HEATING SURFACE <\/td>\n<\/tr>\n
81<\/td>\nSECTION 508 COMMERCIAL KITCHEN MAKEUP AIR
SECTION 509 FIRE SUPPRESSION SYSTEMS
SECTION 510 HAZARDOUS EXHAUST SYSTEMS <\/td>\n<\/tr>\n
83<\/td>\nTABLE 510.8 MINIMUM DUCT THICKNESS
TABLE 510.8.2 CLEARANCE TO COMBUSTIBLES
SECTION 511 DUST, STOCK AND REFUSE CONVEYING SYSTEMS <\/td>\n<\/tr>\n
84<\/td>\nTABLE 511.2 CONSTRUCTION, CLEARANCE AND TERMINATION REQUIREMENTS FOR SINGLE-WALL METAL CHIMNEYS
SECTION 512 SUBSLAB SOIL EXHAUST SYSTEMS
SECTION 513 SMOKE CONTROL SYSTEMS <\/td>\n<\/tr>\n
86<\/td>\n(Equation 5-2)
(Equation 5-3) <\/td>\n<\/tr>\n
87<\/td>\n(Equation 5-4) <\/td>\n<\/tr>\n
88<\/td>\nSECTION 514 ENERGY RECOVERY VENTILATION SYSTEMS <\/td>\n<\/tr>\n
89<\/td>\nCHAPTER 6 DUCT SYSTEMS
SECTION 601 GENERAL
SECTION 602 PLENUMS <\/td>\n<\/tr>\n
90<\/td>\nSECTION 603 DUCT CONSTRUCTION AND INSTALLATION <\/td>\n<\/tr>\n
91<\/td>\nTABLE 603.4 DUCT CONSTRUCTION MINIMUM SHEET METAL THICKNESSES FOR SINGLE DWELLING UNITS <\/td>\n<\/tr>\n
92<\/td>\nSECTION 604 INSULATION <\/td>\n<\/tr>\n
93<\/td>\nSECTION 605 AIR FILTERS
SECTION 606 SMOKE DETECTION SYSTEMS CONTROL <\/td>\n<\/tr>\n
94<\/td>\nSECTION 607 DUCT AND TRANSFER OPENINGS
TABLE 607.3.1 FIRE DAMPER RATING <\/td>\n<\/tr>\n
99<\/td>\nCHAPTER 7 COMBUSTION AIR
SECTION 701 GENERAL
SECTION 702 INDOOR AIR
SECTION 703 OUTDOOR AIR <\/td>\n<\/tr>\n
100<\/td>\nSECTION 704 COMBINED USE OF INDOOR AND OUTDOOR AIR (CONDITION 1)
SECTION 705 COMBINED USE OF INDOOR AND OUTDOOR AIR (CONDITION 2)
SECTION 706 FORCED COMBUSTION AIR SUPPLY
SECTION 707 DIRECT CONNECTION <\/td>\n<\/tr>\n
101<\/td>\nSECTION 708 COMBUSTION AIR DUCTS
SECTION 709 OPENING OBSTRUCTIONS
SECTION 710 OPENING LOCATION AND PROTECTION <\/td>\n<\/tr>\n
103<\/td>\nCHAPTER 8 CHIMNEYS AND VENTS
SECTION 801 GENERAL <\/td>\n<\/tr>\n
104<\/td>\nSECTION 802 VENTS
TABLE 802.2 VENT APPLICATION <\/td>\n<\/tr>\n
105<\/td>\nSECTION 803 CONNECTORS
TABLE 803.9(1) MINIMUM CHIMNEY CONNECTOR THICKNESS FORLOW-HEAT APPLIANCES
TABLE 803.9(2) MINIMUM CHIMNEY CONNECTOR THICKNESS FORMEDIUM- AND HIGH-HEAT APPLIANCES <\/td>\n<\/tr>\n
106<\/td>\nTABLE 803.10.4 CHIMNEY CONNECTOR SYSTEMS AND CLEARANCES TO COMBUSTIBLE WALL MATERIALS FOR DOMESTIC HEATING APPLIANCESa,b,c,d
TABLE 803.10.6 CONNECTOR CLEARANCES TO COMBUSTIBLES
SECTION 804 DIRECT-VENT, INTEGRAL VENT AND MECHANICAL DRAFT SYSTEMS <\/td>\n<\/tr>\n
107<\/td>\nSECTION 805 FACTORY-BUILT CHIMNEYS <\/td>\n<\/tr>\n
108<\/td>\nSECTION 806 METAL CHIMNEYS <\/td>\n<\/tr>\n
109<\/td>\nCHAPTER 9 SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT
SECTION 901 GENERAL
SECTION 902 MASONRY FIREPLACES
SECTION 903 FACTORY-BUILT FIREPLACES
SECTION 904 PELLET FUEL-BURNING APPLIANCES
SECTION 905 FIREPLACE STOVES AND ROOM HEATERS
SECTION 906 FACTORY-BUILT BARBECUE APPLIANCES
SECTION 907 INCINERATORS AND CREMATORIES
SECTION 908 COOLING TOWERS, EVAPORATIVE CONDENSERS AND FLUID COOLERS <\/td>\n<\/tr>\n
110<\/td>\nSECTION 909 VENTED WALL FURNACES
SECTION 910 FLOOR FURNACES
SECTION 911 DUCT FURNACES
SECTION 912 INFRARED RADIANT HEATERS
SECTION 913 CLOTHES DRYERS <\/td>\n<\/tr>\n
111<\/td>\nSECTION 914 SAUNA HEATERS
SECTION 915 ENGINE AND GAS TURBINE-POWERED EQUIPMENT AND APPLIANCES
SECTION 916 POOL AND SPA HEATERS
SECTION 917 COOKING APPLIANCES
SECTION 918 FORCED-AIR WARM-AIR FURNACES <\/td>\n<\/tr>\n
112<\/td>\nSECTION 919 CONVERSION BURNERS
SECTION 920 UNIT HEATERS <\/td>\n<\/tr>\n
113<\/td>\nSECTION 921 VENTED ROOM HEATERS
SECTION 922 KEROSENE AND OIL-FIRED STOVES
SECTION 923 SMALL CERAMIC KILNS
SECTION 924 STATIONARY FUEL CELL POWER SYSTEMS
SECTION 925 MASONRY HEATERS
SECTION 926 GASEOUS HYDROGEN SYSTEMS <\/td>\n<\/tr>\n
115<\/td>\nCHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS
SECTION 1001 GENERAL
SECTION 1002 WATER HEATERS
SECTION 1003 PRESSURE VESSELS
SECTION 1004 BOILERS <\/td>\n<\/tr>\n
116<\/td>\nSECTION 1005 BOILER CONNECTIONS
SECTION 1006 SAFETY AND PRESSURE RELIEF VALVES AND CONTROLS
SECTION 1007 BOILER LOW-WATER CUTOFF <\/td>\n<\/tr>\n
117<\/td>\nSECTION 1008 STEAM BLOWOFF VALVE
SECTION 1009 HOT WATER BOILER EXPANSION TANK
(Equation 10-1)
SECTION 1010 GUAGES
SECTION 1011 TESTS <\/td>\n<\/tr>\n
119<\/td>\nCHAPTER 11 REFRIGERATION
SECTION 1101 GENERAL
SECTION 1102 SYSTEM REQUIREMENTS <\/td>\n<\/tr>\n
120<\/td>\nSECTION 1103 REFRIGERATION SYSTEM CLASSIFICATION
SECTION 1104 SYSTEM APPLICATION REQUIREMENTS <\/td>\n<\/tr>\n
121<\/td>\nTABLE 1103.1REFRIGERANT CLASSIFICATION, AMOUNT AND TLV-TWA <\/td>\n<\/tr>\n
122<\/td>\nTABLE 1103.1\u2014continued REFRIGERANT CLASSIFICATION, AMOUNT AND TLV-TWA <\/td>\n<\/tr>\n
123<\/td>\nTABLE 1103.1\u2014continued REFRIGERANT CLASSIFICATION, AMOUNT AND TLV-TWA <\/td>\n<\/tr>\n
124<\/td>\nTABLE 1104.3.2MAXIMUM PERMISSIBLE QUANTITIES OF REFRIGERANTS <\/td>\n<\/tr>\n
125<\/td>\nSECTION 1105 MACHINERY ROOM, GENERAL REQUIREMENTS
(Equation 11-1) <\/td>\n<\/tr>\n
126<\/td>\n(Equation 11-2)
SECTION 1106 MACHINERY ROOM, SPECIAL REQUIREMENTS
SECTION 1107 REFRIGERANT PIPING <\/td>\n<\/tr>\n
127<\/td>\nSECTION 1108 FIELD TEST <\/td>\n<\/tr>\n
128<\/td>\nSECTION 1109 PERIODIC TESTING <\/td>\n<\/tr>\n
129<\/td>\nCHAPTER 12 HYDRONIC PIPING
SECTION 1201 GENERAL
SECTION 1202 MATERIAL
TABLE 1202.4 HYDRONIC PIPE
TABLE 1202.4\u2014continued HYDRONIC PIPE
TABLE 1202.5 HYDRONIC PIPE FITTINGS
SECTION 1203 JOINTS AND CONNECTIONS <\/td>\n<\/tr>\n
131<\/td>\nSECTION 1204 PIPE INSULATION
SECTION 1205 VALVES
SECTION 1206 PIPING INSTALLATION <\/td>\n<\/tr>\n
132<\/td>\nSECTION 1207 TRANSFER FLUID
SECTION 1208 TESTS
SECTION 1209 EMBEDDED PIPING <\/td>\n<\/tr>\n
133<\/td>\nCHAPTER 13 FUEL OIL PIPING AND STORAGE
SECTION 1301 GENERAL
SECTION 1302 MATERIAL
TABLE 1302.3 FUEL OIL PIPING
SECTION 1303 JOINTS AND CONNECTIONS <\/td>\n<\/tr>\n
134<\/td>\nSECTION 1304 PIPING SUPPORT
SECTION 1305 FUEL OIL SYSTEM INSTALLATION <\/td>\n<\/tr>\n
135<\/td>\nSECTION 1306 OIL GAUGING
SECTION 1307 FUEL OIL VALVES
SECTION 1308 TESTING <\/td>\n<\/tr>\n
137<\/td>\nCHAPTER 14 SOLAR SYSTEMS
SECTION 1401 GENERAL
SECTION 1402 INSTALLATION
SECTION 1403 HEAT TRANSFER FLUIDS <\/td>\n<\/tr>\n
138<\/td>\nSECTION 1404 MATERIALS <\/td>\n<\/tr>\n
139<\/td>\nCHAPTER 15 REFERENCED STANDARDS
ACCA
ANSI
ARI
ASHRAE <\/td>\n<\/tr>\n
140<\/td>\nASME
ASSE
ASTM <\/td>\n<\/tr>\n
142<\/td>\nAWS
CPSC
CSA
DOL
FS
ICC <\/td>\n<\/tr>\n
143<\/td>\nIIAR
MSS
NAIMA
NFPA <\/td>\n<\/tr>\n
144<\/td>\nSMACNA
UL <\/td>\n<\/tr>\n
147<\/td>\nAPPENDIX A COMBUSTION AIR OPENINGS AND CHIMNEY CONNECTOR PASS-THROUGHS
FIGURE A-1 ALL AIR FROM INSIDE THE BUILDING
FIGURE A-2 ALL AIR FROM OUTDOORS\u2014INLET AIR FROM VENTILATED CRAWL SPACE AND OUTLET AIR TO VENTILATED ATTIC <\/td>\n<\/tr>\n
148<\/td>\nFIGURE A-3 ALL AIR FROM OUTDOORS THROUGH VENTILATED ATTIC
FIGURE A-4 AIR FROM OUTDOORS THROUGH HORIZONTAL DUCTS OR DIRECT OPENINGS <\/td>\n<\/tr>\n
149<\/td>\nFIGURE A-5 CHIMNEY CONNECTOR SYSTEMS <\/td>\n<\/tr>\n
150<\/td>\nFIGURE A-5\u2014continued CHIMNEY CONNECTOR SYSTEMS <\/td>\n<\/tr>\n
151<\/td>\nAPPENDIX B ENFORCEMENT SUMMARY OF OHIO PIPING SYSTEMS (Nov. 2006)
ENFORCEMENT SUMMARY OF OHIO PIPING SYSTEMS <\/td>\n<\/tr>\n
155<\/td>\nAPPENDIX C BUILDING SERVICES PIPING TESTING REQUIREMENTS
BUILDING SERVICES PIPING TESTING REQUIREMENTS <\/td>\n<\/tr>\n
157<\/td>\nOHIO BOILER AND PRESSURE VESSEL RULES
4101: 4-1-01 DEFINITIONS <\/td>\n<\/tr>\n
158<\/td>\n4101:4-2-01 SCOPE, ADMINISTRATION, AND ENFORCEMENT <\/td>\n<\/tr>\n
159<\/td>\n4101:4-2-02 TYPES AND QUALIFICATIONS OF INSPECTORS
4101:4-3-01 ACCEPTED ENGINEERING PRACTICE ANDAPPROVED STANDARDS <\/td>\n<\/tr>\n
160<\/td>\nTABLE 4-3-01
4101:4-4-01 DESIGN OF BOILERS AND PRESSURE VESSELS
4101:4-4-02 MAXIMUM ALLOWABLE WORKING PRESSUREFOR NEW BOILERS AND PRESSURE VESSELS <\/td>\n<\/tr>\n
161<\/td>\n4101:4-4-03 SAFETY DEVICES AND CONTROLS
4101:4-4-04 STEAM BOILER BLOWOFF SYSTEMS
TABLE 4-4-04 (C)
TABLE 4-4-04 (D)
4101:4-4-05 CLEARANCES <\/td>\n<\/tr>\n
162<\/td>\n4101:4-5-01 BOILERS AND PRESSURE VESSELS OF SPECIALDESIGN
4101:4-6-01 CONSTRUCTION AND STAMPING OF BOILERSAND PRESSURE VESSELS
4101:4-7-01 CONTRACTOR REGISTRATION AND BOILERPERMITS <\/td>\n<\/tr>\n
163<\/td>\n4101:4-8-01 INSPECTION OF BOILERS AND PRESSUREVESSELS
4101:4-9-01 EXISTING BOILERS AND PRESSURE VESSELS <\/td>\n<\/tr>\n
164<\/td>\nSTRENGTH OF EXISTING RIVETS IN SHEAR <\/td>\n<\/tr>\n
165<\/td>\nSIZES OF RIVETS IN INCHES BASED ON PLATE THICKNESS
4101:4-10-01 LICENSURE AND ATTENDANCE REQUIREMENTSOF OPERATORS <\/td>\n<\/tr>\n
167<\/td>\nAPPENDIX A <\/td>\n<\/tr>\n
168<\/td>\nOhio Approval Process for New and Existing Boilers <\/td>\n<\/tr>\n
169<\/td>\nAPPENDIX B <\/td>\n<\/tr>\n
170<\/td>\nOhio Approval Process for New and Existing Pressure Vessels <\/td>\n<\/tr>\n
171<\/td>\nINDEX <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Ohio Mechanical Code<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
OH<\/b><\/a><\/td>\n2007<\/td>\n174<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":26064,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2727],"product_tag":[],"class_list":{"0":"post-26063","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-oh","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/26063","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/26064"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=26063"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=26063"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=26063"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}