{"id":18674,"date":"2024-10-16T22:42:01","date_gmt":"2024-10-16T22:42:01","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-b306-2009\/"},"modified":"2024-10-24T12:40:28","modified_gmt":"2024-10-24T12:40:28","slug":"astm-b306-2009","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-b306-2009\/","title":{"rendered":"ASTM-B306 2009"},"content":{"rendered":"
This specification establishes the requirements for seamless copper tube (DWV) produced from Copper UNS No. C12200 and intended for sanitary drainage, waste, and vent piping. The tube shall be manufactured by such hot- or cold-working process as to produce a homogeneous uniform wrought structure in the finished product. The tube shall be cold drawn to the specified finished size, wall thickness, tensile strength, and Rockwell hardness. The tube shall be subjected to chemical analysis, Eddy-current test, and pneumatic test. Instead of sampling in accordance with Practice E 255, the manufacturer shall have the option of sampling at the time casting are poured or from the semifinished product, subject to the conditions set in the specification.<\/p>\n
This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date. <\/i> <\/font><\/p>\n Significance and Use <\/b><\/p>\n For the purpose of determining compliance with the specified limits for requirements of the properties listed in the following table, an observed value or a calculated value shall be rounded as indicated in accordance with the rounding method of Practice E 29: <\/p>\n 1. Scope <\/b><\/p>\n 1.1 This specification establishes the requirements for seamless copper tube (DWV) produced from Copper UNS No. C12200 and intended for sanitary drainage, waste, and vent piping.<\/p>\n Note <\/span> 1\u2014Fittings used for soldered or brazed connections in drainage, waste, or vent systems are described in ASME Standards B16.23 and B16.29 and CSA Standard B158.1.<\/p>\n Note <\/span> 2\u2014The assembly of copper drainage, waste, and vent systems by soldering is described in Practice B 828.<\/p>\n Note <\/span> 3\u2014Solders for joining copper drainage, waste, or vent systems are described in Specification B 32. The requirement for acceptable fluxes for these systems are described in Specification B 813.<\/p>\n 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.<\/p>\n 1.3 The following hazard statement pertains only to the test method described in Section 16.2.3 of this specification: <\/span> This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. <\/span> <\/span><\/p>\n 2. Referenced Documents <\/b> (purchase separately) <\/i> The documents listed below are referenced within the subject standard but are not provided as part of the standard.<\/span><\/p>\n ASTM Standards <\/b><\/p>\n B32<\/span> Specification for Solder Metal B601<\/span> Classification for Temper Designations for Copper and Copper Alloys–Wrought and Cast B813<\/span> Specification for Liquid and Paste Fluxes for Soldering of Copper and Copper Alloy Tube B828<\/span> Practice for Making Capillary Joints by Soldering of Copper and Copper Alloy Tube and Fittings B900<\/span> Practice for Packaging of Copper and Copper Alloy Mill Products for U.S. Government Agencies E8<\/span> Test Methods for Tension Testing of Metallic Materials E18<\/span> Test Methods for Rockwell Hardness of Metallic Materials E29<\/span> Practice for Using Significant Digits in Test Data to Determine Conformance with Specifications E53<\/span> Test Method for Determination of Copper in Unalloyed Copper by Gravimetry E62<\/span> Test Methods for Chemical Analysis of Copper and Copper Alloys (Photometric Methods) E243<\/span> Practice for Electromagnetic (Eddy-Current) Examination of Copper and Copper-Alloy Tubes E255<\/span> Practice for Sampling Copper and Copper Alloys for the Determination of Chemical Composition \n<\/div>\n","protected":false},"excerpt":{"rendered":" B306-09 Standard Specification for Copper Drainage Tube (DWV) (Redline)<\/b><\/p>\n\n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n ASTM<\/b><\/a><\/td>\n 2009<\/td>\n 8<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":18675,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2637],"product_tag":[],"class_list":{"0":"post-18674","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-astm","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/18674","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/18675"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=18674"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=18674"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=18674"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}