{"id":154499,"date":"2024-10-19T09:11:38","date_gmt":"2024-10-19T09:11:38","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ashrae-standard-110-2016\/"},"modified":"2024-10-25T01:27:15","modified_gmt":"2024-10-25T01:27:15","slug":"ashrae-standard-110-2016","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ashrae\/ashrae-standard-110-2016\/","title":{"rendered":"ASHRAE Standard 110 2016"},"content":{"rendered":"

First published in 1985 and revised in 1995, ASHRAE Standard 110 provides a method of testing the performance of laboratory fume hoods. This revised edition has been expanded in a number of significant ways: The test procedures now require digital collection of data rather than allowing manual data collection. Some modifications have been made to the test procedure. These modifications were made based on the experience of the committee members or to clarify statements in the 1995 edition of the standard. Informative Appendix A, which provides explanatory information, has been expanded. Informative Appendix B, a new nonmandatory section, provides guidance to anyone using the standard as a diagnostic tool in investigating the cause of poor hood performance. The aim of this standard is to provide a test that takes into account the wide variety of factors that influence the performance of laboratory fume hoods.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nANSI\/ASHRAE Standard 110-2016 <\/td>\n<\/tr>\n
3<\/td>\nCONTENTS <\/td>\n<\/tr>\n
4<\/td>\nFOREWORD <\/td>\n<\/tr>\n
5<\/td>\n1. PURPOSE
2. SCOPE
3. DEFINITIONS AND ABBREVIATIONS <\/td>\n<\/tr>\n
8<\/td>\n4. INSTRUMENTATION AND EQUIPMENT <\/td>\n<\/tr>\n
15<\/td>\n5. TEST CONDITIONS <\/td>\n<\/tr>\n
16<\/td>\n6. FACE VELOCITY MEASUREMENT PROCEDURE <\/td>\n<\/tr>\n
18<\/td>\n7. FLOW VISUALIZATION PROCEDURE <\/td>\n<\/tr>\n
19<\/td>\n8. TRACER GAS TEST PROCEDURE <\/td>\n<\/tr>\n
20<\/td>\n9. REFERENCES <\/td>\n<\/tr>\n
21<\/td>\nINFORMATIVE APPENDIX A\u2014COMMENTARY AND ADDITIONAL INFORMATION ON STANDARD 110 SECTIONS <\/td>\n<\/tr>\n
28<\/td>\nINFORMATIVE APPENDIX B\u2014DIAGNOSTIC USE OF THIS STANDARD <\/td>\n<\/tr>\n
32<\/td>\nINFORMATIVE APPENDIX C\u2014EXAMPLE REPORT <\/td>\n<\/tr>\n
33<\/td>\nINFORMATIVE APPENDIX D\u2014BIBLIOGRAPHY <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

ASHRAE Standard 110-2016 — Method of Testing Performance of Laboratory Fume Hoods<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ASHRAE<\/b><\/a><\/td>\n2016<\/td>\n36<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":154500,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2719],"product_tag":[],"class_list":{"0":"post-154499","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ashrae","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/154499","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/154500"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=154499"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=154499"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=154499"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}