{"id":79768,"date":"2024-10-17T18:37:43","date_gmt":"2024-10-17T18:37:43","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-11-2000\/"},"modified":"2024-10-24T19:41:17","modified_gmt":"2024-10-24T19:41:17","slug":"ieee-11-2000","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-11-2000\/","title":{"rendered":"IEEE 11 2000"},"content":{"rendered":"

Revision Standard – Active. This standard applies to rotating electric machinery which forms part of the propulsion and major auxiliary equipment on internally and externally powered electrically propelled rail and road vehicles and similar large transport and haulage vehicles and their trailers where specified in the contract.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nTitle Page <\/td>\n<\/tr>\n
3<\/td>\nIntroduction <\/td>\n<\/tr>\n
4<\/td>\nParticipants <\/td>\n<\/tr>\n
5<\/td>\nCONTENTS <\/td>\n<\/tr>\n
7<\/td>\n1. Overview
1.1 Scope
1.2 Purpose
1.3 Service conditions <\/td>\n<\/tr>\n
8<\/td>\n1.4 Test categories
1.5 Electric inputs or outputs <\/td>\n<\/tr>\n
9<\/td>\n2. References
3. Definitions <\/td>\n<\/tr>\n
11<\/td>\n4. Ratings and temperature-rise tests
4.1 Classes of ratings
4.2 Continuous ratings and temperature rise tests
4.3 Initial temperature of machine for temperature-rise test to determine 1 h rating
4.4 Making of short time overload test <\/td>\n<\/tr>\n
12<\/td>\n4.5 Ventilation during temperature rise test
4.6 Waveforms during temperature rise tests
4.7 Voltage during temperature rise test
4.8 Rated voltage <\/td>\n<\/tr>\n
13<\/td>\n4.9 Contract ratings
5. Temperature rises and temperature rise tests
5.1 Limits of temperature rise <\/td>\n<\/tr>\n
15<\/td>\n5.2 Waiver of temperature rise limits
5.3 Separability
5.4 Rotor cage windings
6. Temperature measurements
6.1 Measurement of the cooling air temperature during tests <\/td>\n<\/tr>\n
16<\/td>\n6.2 Method of measuring the temperature of parts
6.3 Shutting down machine
6.4 Rules for correcting to time of shutdown <\/td>\n<\/tr>\n
17<\/td>\n7. High potential tests
7.1 Selection of test method
7.2 AC test procedure
7.3 DC test procedure
7.4 Test voltage
7.5 Test voltage for machines operating on circuits with power ground <\/td>\n<\/tr>\n
18<\/td>\n7.6 Test voltage for machines operating on ungrounded circuits
7.7 Test voltage for machines operating on circuits with high impedance ground fault detection
7.8 New completed machines <\/td>\n<\/tr>\n
19<\/td>\n7.9 Repaired machines
7.10 Machines in service condition
7.11 Connected apparatus
8. Commutation tests (dc machines only)
8.1 Commutation type tests <\/td>\n<\/tr>\n
21<\/td>\n8.2 Commutation routine tests
8.3 Interruption type tests <\/td>\n<\/tr>\n
22<\/td>\n8.4 Evaluation of the degree of sparking <\/td>\n<\/tr>\n
23<\/td>\n9. Overspeed requirements and test
9.1 Overspeed test
9.2 Results of overspeed test
9.3 Relation to vehicle speed
10. Characteristic curves and tests
10.1 Characteristic curves <\/td>\n<\/tr>\n
24<\/td>\n10.2 Methods of determining efficiency <\/td>\n<\/tr>\n
25<\/td>\n10.3 Losses to be considered for direct current machines
10.4 Determination of losses in direct current machines <\/td>\n<\/tr>\n
27<\/td>\n10.5 Losses to be considered for inverter driven induction motors
10.6 Determination of losses in inverter driven induction motors <\/td>\n<\/tr>\n
29<\/td>\n10.7 Declared curve type tests and tolerances <\/td>\n<\/tr>\n
30<\/td>\n10.8 Routine characteristic tests and tolerances
10.9 Gear losses <\/td>\n<\/tr>\n
32<\/td>\n11. External power systems
11.1 Supply voltage <\/td>\n<\/tr>\n
33<\/td>\n11.2 Propulsion performance voltage
11.3 Supply characteristics
11.4 DC systems using regeneration
12. Terminal marking
12.1 Traction motors <\/td>\n<\/tr>\n
34<\/td>\n12.2 Rotating machines other than traction motors <\/td>\n<\/tr>\n
36<\/td>\n12.3 Reactors
12.4 Connection diagrams
12.5 Additional terminals
13. Mechanical measurements
13.1 Commutator trueness <\/td>\n<\/tr>\n
37<\/td>\n13.2 Vibration
13.3 Sound <\/td>\n<\/tr>\n
38<\/td>\n13.4 Shaft voltage <\/td>\n<\/tr>\n
39<\/td>\nAnnex A\u2014Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

IEEE Standard for Rotating Electric Machinery for Rail and Road Vehicles<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
IEEE<\/b><\/a><\/td>\n2000<\/td>\n39<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":79769,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2644],"product_tag":[],"class_list":{"0":"post-79768","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ieee","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/79768","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/79769"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=79768"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=79768"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=79768"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}