{"id":58813,"date":"2024-10-17T10:54:24","date_gmt":"2024-10-17T10:54:24","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-d3230-2005\/"},"modified":"2024-10-24T17:34:49","modified_gmt":"2024-10-24T17:34:49","slug":"astm-d3230-2005","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-d3230-2005\/","title":{"rendered":"ASTM-D3230 2005"},"content":{"rendered":"<\/p>\n
1.1 This test method covers the determination of the approximate chloride (salts) concentration in crude oil. The range of concentration covered is 0 to 500 mg\/kg or 0 to 150 lb\/1000 bbl as chloride concentration\/volume of crude oil.<\/p>\n
1.2 This test method measures conductivity in the crude oil due to the presence of common chlorides, such as sodium, calcium, and magnesium. Other conductive materials may also be present in the crude oil.<\/p>\n
1.3 The values stated in SI units are to be regarded as standard. Acceptable concentration units are g\/m 3<\/sup> or PTB (lb\/1000 bbl).<\/p>\n This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific warning statements, see , , and .<\/p>\n D3230-05a Standard Test Method for Salts in Crude Oil (Electrometric Method)<\/b><\/p>\nPDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 1<\/td>\n Scope
Referenced Documents
Terminology
Summary of Test Method
Significance and Use
Apparatus <\/td>\n<\/tr>\n\n 2<\/td>\n Reagents and Materials
Sampling
Preparation of Apparatus
Calibration <\/td>\n<\/tr>\n\n 3<\/td>\n Procedure
Calculation
Report
Precision and Bias
TABLE 1 <\/td>\n<\/tr>\n\n 4<\/td>\n Keywords
A1. APPARATUS
A1.1 Electrometric Chloride Apparatus (Custom Manufacture) (see
FIG. A1.1 <\/td>\n<\/tr>\n\n 5<\/td>\n A1.3 Electrometric Chloride Apparatus (Commercial Manufacture)4
A1.4 Test Cell Components (Commercial Manufacture)
FIG. A1.2 <\/td>\n<\/tr>\n\n 6<\/td>\n FIG. A1.3 <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" \n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n ASTM<\/b><\/a><\/td>\n 2005<\/td>\n 7<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":58814,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2637],"product_tag":[],"class_list":{"0":"post-58813","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-astm","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/58813","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/58814"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=58813"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=58813"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=58813"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}