{"id":359313,"date":"2024-10-20T01:25:30","date_gmt":"2024-10-20T01:25:30","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bsi-pd-iso-iec-tr-11801-99032015\/"},"modified":"2024-10-26T02:06:14","modified_gmt":"2024-10-26T02:06:14","slug":"bsi-pd-iso-iec-tr-11801-99032015","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bsi-pd-iso-iec-tr-11801-99032015\/","title":{"rendered":"BSI PD ISO\/IEC TR 11801-9903:2015"},"content":{"rendered":"
This part of ISO\/IEC 11801<\/span> <\/span> establishes a matrix-model for formulating limits for differential mode parameters for return loss, insertion loss, and near and far end crosstalk, within and between two pairs of balanced cabling. This is for the purpose of supporting new, improved balanced cabling channel and link specifications, which are expected to be included in the next edition of ISO\/IEC 11801<\/span> <\/span> 1<\/sup> <\/span>.<\/p>\n Information technology. Generic cabling systems for customer premises – Matrix modelling of channels and links<\/b><\/p>\nPDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 4<\/td>\n CONTENTS <\/td>\n<\/tr>\n \n 6<\/td>\n FOREWORD <\/td>\n<\/tr>\n \n 8<\/td>\n INTRODUCTION
Figures
Figure\u00a01 \u2013 Link configurations of ISO\/IEC\u00a011801:2002 <\/td>\n<\/tr>\n\n 10<\/td>\n 1 Scope
2 Normative references
3 Terms, definitions and abbreviations
3.1 Terms and definitions <\/td>\n<\/tr>\n\n 11<\/td>\n 3.2 Abbreviations
4 Matrix model <\/td>\n<\/tr>\n\n 12<\/td>\n 5 Matrix definition
5.1 Quadriports
5.2 Matrix port definition for a two pair system representative for modelling purposes
5.3 Operational scattering matrix
Figure\u00a02 \u2013 Matrix definition of a 4 port 2 twisted pair system <\/td>\n<\/tr>\n\n 13<\/td>\n 5.4 General naming convention
5.5 S-Matrix
Figure\u00a03 \u2013 Operational scattering parameters example from port 2
Figure\u00a04 \u2013 All 4 ports operational scattering parameter definition
Figure\u00a05 \u2013 S-Matrix definition showing corresponding S parameters <\/td>\n<\/tr>\n\n 14<\/td>\n 5.6 Passivity
5.7 Operational reflexion loss matrix
Figure\u00a06 \u2013 Equal S parameters for real components
Figure\u00a07 \u2013 Final operational scattering matrix for real components <\/td>\n<\/tr>\n\n 15<\/td>\n 5.8 Transmission matrix (T-matrix)
5.9 S-matrix of cabling
6 Calculation with matrices using limit lines
Figure\u00a08 \u2013 Definition of the operational reflection loss matrixwith unitarity included (see C.3.6)
Figure\u00a09 \u2013 Transmission matrix concatenation showingan example of a 2 connector permanent link <\/td>\n<\/tr>\n\n 16<\/td>\n 7 Extracting limit lines
7.1 General
7.2 Equations to extract the cabling limit lines
7.2.1 Operational attenuation
Figure\u00a010 \u2013 Graphical example of a NEXT-L calculation showing statistical results (red) and final calculation (blue) <\/td>\n<\/tr>\n\n 17<\/td>\n 7.2.2 Near end crosstalk
7.2.3 Attenuation to far end crosstalk ratio
7.2.4 Reflection
8 Component values to be used as input to the model
8.1 General <\/td>\n<\/tr>\n\n 18<\/td>\n 8.2 Cable
8.2.1 General
8.2.2 Wave attenuation
8.2.3 Near end crosstalk
8.2.4 Far end crosstalk
8.2.5 Reflection <\/td>\n<\/tr>\n\n 19<\/td>\n 8.3 Connections
8.3.1 General
8.3.2 As point source of disturbance
Figure\u00a011 \u2013 100 m cable return loss without reflection at both ends
Figure\u00a012 \u2013 100 m cable return loss with a reflection of 0,03 at both ends (6\u00a0\u2126 mismatch, ~23 dB return loss at 1 MHz) <\/td>\n<\/tr>\n\n 20<\/td>\n 8.3.3 As a transmission line <\/td>\n<\/tr>\n \n 21<\/td>\n Annex A (informative) S to T and T to S-matrix conversion formulas
A.1 Overview
A.2 Formulas <\/td>\n<\/tr>\n\n 22<\/td>\n Annex B (informative) Calculation examples
B.1 Overview
B.2 Component assumptions for modelling purposes
B.2.1 Cables
Tables
Table\u00a0B.1 \u2013 Modelling assumptions for cable transmission parameters <\/td>\n<\/tr>\n\n 23<\/td>\n B.2.2 Connections
B.3 Model results
B.3.1 General
B.3.2 Insertion loss
Table\u00a0B.2 \u2013 Modelling assumptions for connection transmission parameters
Table\u00a0B.3 \u2013 Insertion loss <\/td>\n<\/tr>\n\n 24<\/td>\n B.3.3 NEXT
B.3.4 ACR-F
B.3.5 Return loss
Table\u00a0B.4 \u2013 NEXT
Table\u00a0B.5 \u2013 ACR-F
Table\u00a0B.6 \u2013 Return loss <\/td>\n<\/tr>\n\n 25<\/td>\n Annex C (informative) Terms and definitions
C.1 Comparison of namings
Table\u00a0C.1 \u2013 Comparison of naming in ISO\/IEC 11081:2002 and this technical report <\/td>\n<\/tr>\n\n 26<\/td>\n C.2 General
C.3 Background of terms and definitions
C.3.1 Operational attenuation <\/td>\n<\/tr>\n\n 27<\/td>\n Figure\u00a0C.1 \u2013 Defining the operational attenuation andthe operational transfer functions of a two-port <\/td>\n<\/tr>\n \n 28<\/td>\n C.3.2 Operational transfer function (TB)
C.3.3 Image or wave transfer function (T)
C.3.4 Insertion transfers function of a two-port (TBI)
C.3.5 Insertion transfer function (TBI) measured with a NWA
C.3.6 Operational reflection loss transfer function (Tref = Sref) of a junction <\/td>\n<\/tr>\n\n 29<\/td>\n Figure\u00a0C.2 \u2013 Defining the reflection transfer functions and the return loss of a junction <\/td>\n<\/tr>\n \n 30<\/td>\n Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" \n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n BSI<\/b><\/a><\/td>\n 2015<\/td>\n 32<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":359322,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2641],"product_tag":[],"class_list":{"0":"post-359313","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-bsi","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/359313","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/359322"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=359313"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=359313"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=359313"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}