{"id":104695,"date":"2024-10-18T14:02:06","date_gmt":"2024-10-18T14:02:06","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-e740-2003\/"},"modified":"2024-10-24T21:30:56","modified_gmt":"2024-10-24T21:30:56","slug":"astm-e740-2003","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-e740-2003\/","title":{"rendered":"ASTM-E740 2003"},"content":{"rendered":"
Scope<\/strong><\/p>\n 1.1 This practice covers the design, preparation, and testing of surface-crack tension (SCT) specimens. It relates specifically to testing under continuously increasing force and excludes cyclic and sustained loadings. The quantity determined is the residual strength of a specimen having a semielliptical or circular-segment fatigue crack in one surface. This value depends on the crack dimensions and the specimen thickness as well as the characteristics of the material.<\/p>\n 1.2 Metallic materials that can be tested are not limited by strength, thickness, or toughness. However, tests of thick specimens of tough materials may require a tension test machine of extremely high capacity. The applicability of this practice to nonmetallic materials has not been determined.<\/p>\n 1.3 This practice is limited to specimens having a uniform rectangular cross section in the test section. The test section width and length must be large with respect to the crack length. Crack depth and length should be chosen to suit the ultimate purpose of the test.<\/p>\n 1.4 Residual strength may depend strongly upon temperature within a certain range depending upon the characteristics of the material. This practice is suitable for tests at any appropriate temperature.<\/p>\n 1.5 Residual strength is believed to be relatively insensitive to loading rate within the range normally used in conventional tension tests. When very low or very high rates of loading are expected in service, the effect of loading rate should be investigated using special procedures that are beyond the scope of this practice.<\/p>\n Note 1\u2014Further information on background and need for this type of test is given in the report of ASTM Task Group E24.01.05 on Part-Through-Crack Testing (1<\/b>).<\/p>\n 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.<\/i><\/p>\n Keywords<\/strong><\/p>\n residual strength; surface crack; tensile force<\/p>\n ICS Code<\/strong><\/p>\n ICS Number Code 77.040.10 (Mechanical testing of metals)<\/p>\n DOI:<\/strong> 10.1520\/E0740-03<\/p>\n<\/div>\n E740-03 Standard Practice for Fracture Testing with Surface-Crack Tension Specimens<\/b><\/p>\nPDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 1<\/td>\n Scope
Referenced Documents
Terminology <\/td>\n<\/tr>\n\n 2<\/td>\n Significance and Use
Apparatus
Test Specimen <\/td>\n<\/tr>\n\n 3<\/td>\n Procedure
Report
FIG. 1 <\/td>\n<\/tr>\n\n 4<\/td>\n Keywords
A1. FATIGUE CRACK SIZE AND SHAPE CONTROL
A1.1
A1.2
A1.3
FIG. 2 <\/td>\n<\/tr>\n\n 5<\/td>\n A2. STRESS INTENSITY FACTOR EQUATIONS
A2.1
A2.2
A2.3
A2.4 <\/td>\n<\/tr>\n\n 6<\/td>\n X1. METHODS FOR FURTHER ANALYSIS
X1.1
X1.2
FIG. A2.1 <\/td>\n<\/tr>\n\n 7<\/td>\n X1.3
X1.4
X2. CRACK MOUTH OPENING DISPLACEMENT
X2.1
X2.2
X2.3 <\/td>\n<\/tr>\n\n 8<\/td>\n X3. TEST PLAN
X3.1
X3.2
X3.3
X3.4
REFERENCES
FIG. X2.1 <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"\n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n ASTM<\/b><\/a><\/td>\n 2003<\/td>\n 9<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":104696,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[1088,2637],"product_tag":[],"class_list":{"0":"post-104695","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-77-040-10","7":"product_cat-astm","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/104695","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/104696"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=104695"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=104695"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=104695"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}