BS EN ISO 18365:2013
$142.49
Hydrometry. Selection, establishment and operation of a gauging station
Published By | Publication Date | Number of Pages |
BSI | 2013 | 26 |
This International Standard gives requirements for the establishment and operation of a gauging station for the measurement of stage, or stage and discharge, of a lake, reservoir, river or canal or other artificial open channel. It also describes how a gauging station utilizing one of the measurement methods listed should be operated and maintained.
Requirements are provided for stage only measurement stations, stage–discharge stations and direct-discharge measurement stations in natural channels, as well as for stage–discharge stations with artificial structures. Additionally, some requirements are given for measurements under difficult conditions, such as under ice conditions.
PDF Catalog
PDF Pages | PDF Title |
---|---|
4 | Foreword |
6 | Foreword |
7 | Section sec_1 Section sec_2 Section sec_3 Section sec_4 Section sec_4.1 1 Scope 2 Normative references 3 Terms, definitions and symbols 4 General requirements and considerations 4.1 Requirements |
8 | Section sec_4.2 Section sec_5 Section sec_5.1 Section sec_5.1.1 Section sec_5.1.2 4.2 Other constraints 5 Water level (Stage) only gauging stations 5.1 Preliminary survey and selection criteria |
9 | Section sec_5.1.3 Section sec_5.2 Section sec_5.2.1 Section sec_5.2.2 Section sec_5.2.3 Section sec_5.2.4 5.2 Stage measurement and recording |
10 | Section sec_5.2.5 Section sec_5.2.6 Section sec_6 Section sec_6.1 6 Stage-discharge gauging stations 6.1 General |
11 | Section sec_6.2 Section sec_6.2.1 Section sec_6.2.2 Section sec_6.2.3 Section sec_6.2.4 6.2 Main elements of a stage-discharge gauging station |
12 | Section sec_6.2.5 Section sec_7 Section sec_7.1 Section sec_7.2 Section sec_7.3 7 Stage- discharge gauging stations using hydraulic structures 7.1 General 7.2 Site selection 7.3 Types of hydraulic structures |
13 | Section sec_8 Section sec_8.1 8 Velocity-discharge gauging stations 8.1 Applications and types of instrument |
14 | Section sec_8.2 Section sec_8.3 Section sec_8.4 8.2 Site selection 8.3 Calibration 8.4 Transit time (acoustic) method |
15 | Section sec_8.5 8.5 Doppler |
16 | Section sec_8.6 Section sec_8.7 Section sec_9 Section sec_9.1 Section sec_9.1.1 Section sec_9.1.2 Section sec_9.1.3 8.6 Acoustic (echo) correlation velocity meters 8.7 Electromagnetic method (Full channel width coil) 9 Measurement under difficult conditions 9.1 Ice and frost conditions |
17 | Section sec_9.2 Section sec_9.3 Section sec_10 Section sec_10.1 Section sec_10.2 9.2 Weed growth 9.3 Extreme sedimentation conditions 10 Operation and maintenance 10.1 General 10.2 Water level (Stage) only gauging stations |
18 | Section sec_10.3 Section sec_10.4 Section sec_10.5 10.3 Stage-discharge gauging stations 10.4 Stage-discharge gauging stations using hydraulic structures 10.5 Velocity-discharge gauging stations |
19 | Annex sec_A Table tab_A.1 Annex A (informative) Applicable conditions for selection of discharge measurement method |
22 | Reference ref_1 Reference ref_2 Reference ref_3 Reference ref_4 Reference ref_5 Reference ref_6 Reference ref_7 Reference ref_8 Reference ref_9 Reference ref_10 Reference ref_11 Reference ref_12 Reference ref_13 Reference ref_14 Reference ref_15 Reference ref_16 Reference ref_17 Reference ref_18 Reference ref_19 Reference ref_20 Reference ref_21 Reference ref_22 Reference ref_23 Bibliography |
23 | Reference ref_24 Reference ref_25 Reference ref_26 Reference ref_27 Reference ref_28 Reference ref_29 Reference ref_30 Reference ref_31 |