Shopping Cart

No products in the cart.

ASTM-E3376 2023

$34.13

E3376-23 Standard Practice for Calibration and Usage of Germanium Detectors in Radiation Metrology for Reactor Dosimetry

Published By Publication Date Number of Pages
ASTM 2023 10
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. Weā€™re here to assist you 24/7.
Email:[email protected]

ASTM E3376-23

Active Standard: Standard Practice for Calibration and Usage of Germanium Detectors in Radiation Metrology for Reactor Dosimetry

ASTM E3376

Scope

1.1 This standard establishes techniques for calibration, usage, and performance testing of germanium detectors for the measurement of gamma-ray emission rates of radionuclides in radiation metrology for reactor dosimetry. The practice is applicable only to samples of small size, approximating to point sources. It covers the energy and full-energy peak efficiency calibration as well as the determination of gamma-ray energies in the 0.06ā€‰MeV to 2ā€‰MeV energy region and is designed to yield gamma-ray emission rates with an uncertainty of Ā±3ā€‰% (see Note 1). This technique applies to measurements that do not involve overlapping peaks, and in which peak-to-continuum considerations are not important.

Note 1: Uncertainty U is given at the 68ā€‰% confidence level; that is, where Ī“i are the estimated maximum systematic uncertainties, and Ļƒi are the random uncertainties at the 68ā€‰% confidence level. Other techniques of error analysis are in use (1, 2).2

1.2 Additional information on the setup, calibration, and quality control for radiometric detectors and measurements is given in IEEE/ANSI N42.14 and in Guide C1402 and Practice D7282.

1.3 The values stated in SI units are generally to be regarded as standard. The rad is an exception.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Keywords

calibration of germanium detectors; germanium detectors; radiation metrology; reactor dosimetry; usage of germanium detectors;

ICS Code

ICS Number Code 17.240 (Radiation measurements)

DOI: 10.1520/E3376-23

ASTM-E3376 2023
$34.13