ASTM-D7574 2009
$40.63
D7574-09 Standard Test Method for Determination of Bisphenol A in Environmental Waters by Liquid Chromatography/Tandem Mass Spectrometry
Published By | Publication Date | Number of Pages |
ASTM | 2009 | 9 |
1.1 This procedure covers the determination of bisphenol A (BPA) extracted from water utilizing solid phase extraction (SPE), separated using liquid chromatography (LC) and detected with tandem mass spectrometry (MS/MS). BPA is qualitatively and quantitatively determined by this method. This method adheres to multiple reaction monitoring (MRM) mass spectrometry.
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.3 The method detection limit (MDL) and reporting limit (RL) for BPA are listed in Table 1.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
A MDL determined following the Code of Federal Regulations, 40CFR Part 136, Appendix B.
B Lowest point of the reporting range, reporting limit, is calculated from the LV 1 concentration calibration standard in Table 4. Fig. 1 displays the signal/noise ratio at the reporting limit.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Scope Referenced Documents Terminology Summary of Test Method Significance and Use TABLE 1 |
2 | Interferences Apparatus Reagents and Materials |
3 | Hazards Sample Collection, Preservation, and Storage Preparation of LC/MS/MS TABLE 2 |
4 | Calibration and Standardization TABLE 3 FIG. 1 |
5 | TABLE 4 |
6 | FIG. 2 TABLE 5 |
7 | Sample Collection and Solid Phase Extraction Procedure |
8 | Calculation or Interpretation of Results Report Single Laboratory Precision and Bias TABLE 6 |
9 | Keywords TABLE 7 TABLE 8 |