Scope
1.1 This test method covers the determination of hydrocarbon components of petroleum naphthas as enumerated in Table 1. Components eluting after n-nonane (bp 150.8°C) are determined as a single group.
1.2 This test method is applicable to olefin-free (<2 % olefins by liquid volume) liquid hydrocarbon mixtures including virgin naphthas, reformates, and alkylates. Olefin content can be determined by Test Method D 1319. The hydrocarbon mixture must have a 98 % point of 250°C or less as determined by Test Method D 3710.
1.3 Components that are present at the 0.05 mass % level or greater can be determined.
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific warning statements are given in Section 7.
Keywords
alkylate; capillary gas chromatography; hydrocarbon composition; petroleum naphtha; reformate; Alkylates; Automated procedures–petroleum products analysis; Capillary gas chromatography; Composition analysis–petroleum products; Crude petroleum products; Gas chromatography (GC)–petroleum products; Hydrocarbons; Kovats index; Linear retention index; Naphtha and naphtha derivatives; n-Nonane; Petroleum naphtha; Reformate; Split injection linearity
ICS Code
ICS Number Code 71.080.10 (Aliphatic hydrocarbons)
DOI: 10.1520/D5134-98R08E01
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Scope Referenced Documents Summary of Test Method |
2 | TABLE 1 |
3 | Significance and Use Interferences Apparatus |
4 | Reagents and Materials Sampling Preparation of Apparatus |
5 | FIG. 1 |
6 | Column Evaluation FIG. 2 |
7 | FIG. 3 |
8 | Split Injection Linearity Procedure for Gas Chromatographic Analysis of Sample Calculation TABLE 2 |
9 | Report Precision and Bias Keywords TABLE 3 |
10 | A1. KOVATS AND LINEAR RETENTION INDICES A1.1 A1.2 |
11 | A2. MEASUREMENT AND CALCULATION OF FLOW PARAMETERS A2.1 A2.2 A2.3 A2.4 Example |