ASTM-D5099 2008
$40.63
D5099-08 Standard Test Methods for Rubber—Measurement of Processing Properties Using Capillary Rheometry
Published By | Publication Date | Number of Pages |
ASTM | 2008 | 8 |
ASTM D5099-08
Historical Standard: Standard Test Methods for Rubber—Measurement of Processing Properties Using Capillary Rheometry
ASTM D5099
Scope
1.1 These test methods describe how capillary rheometry may be used to measure the rheological characteristics of rubber (raw or compounded). Two methods are addressed: Method A—using a piston type capillary rheometer, and Method B—using a screw extrusion type capillary rheometer. The two methods have important differences, as outlined in 7-10 and 11-14, respectively.
1.2 These test methods cover the use of a capillary rheometer for the measurement of the flow properties of thermoplastic elastomers, unvulcanized rubber, and rubber compounds. These material properties are related to factory processing.
1.3 Since piston type capillary rheometers impart only a small amount of shearing energy to the sample, these measurements directly relate to the state of the compound at the time of sampling. Piston type capillary rheometer measurements will usually differ from measurements with a screw extrusion type rheometer, which imparts shearing energy just before the rheological measurement.
1.4 Capillary rheometer measurements for plastics are described in Test Method D 3835.
1.5 The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Keywords
capillary rheometer; flow properties; piston; processing properties; screw extrusion; shear rate; shear stress; viscosity; Capillary rheometer method; Flow and flow rate–rubber; Piston capillary rheometer; Process control; Raw rubber; Rheology/rheological properties–rubber; Rheometers; Rubber; Screw extrusion
ICS Code
ICS Number Code 83.060 (Rubber)
DOI: 10.1520/D5099-08
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Scope Referenced Documents Terminology |
3 | Significance and Use Interferences Sampling and Conditioning of Samples Summary of Test Method TABLE 1 |
4 | Apparatus FIG. 1 FIG. 2 |
5 | Procedure Calculation TABLE 2 |
6 | Summary of Test Method |
7 | Apparatus Extrusion Procedure FIG. 3 TABLE 3 |
8 | Calculation Report Precision and Bias Keywords |