{"id":444051,"date":"2024-10-20T08:35:49","date_gmt":"2024-10-20T08:35:49","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-c57-13-1-2006\/"},"modified":"2024-10-26T16:02:27","modified_gmt":"2024-10-26T16:02:27","slug":"ieee-c57-13-1-2006","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-c57-13-1-2006\/","title":{"rendered":"IEEE C57.13.1-2006"},"content":{"rendered":"
Revision Standard – Superseded. This guide describes field test methods that assure that current transformers are connected properly, are of marked ratio and polarity, and are in a condition to perform as designed both initially and after having been in service for a period of time.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | IEEE Guide for Field Testing of Relaying Current Transformers <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | Title page <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | Introduction Notice to users <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | Participants <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | CONTENTS <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 1. Overview 1.1 Scope 1.2 Purpose <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 2. Normative references 3. Definitions 4. Consideration of American National Standards Institute (ANSI) accuracy classes <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 5. Precautions in field testing CTs 5.1 Demagnetizing CTs 5.2 Greater primary winding turns <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 6. Types of test and measurements 6.1 Ratio test 6.2 Polarity test 6.3 Insulation resistance test 6.4 Resistance measurement 6.5 Excitation test 6.6 Admittance test <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 6.7 Burden test 7. AC sources for primary current injection tests 8. Ratio tests 8.1 Voltage method <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 8.2 Out-of-service current method <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 8.3 In-service current manual method 8.4 In-service current automated method 9. Polarity 9.1 DC voltage test <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 9.2 AC voltage test–oscilloscope <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 9.3 Current method 9.4 Phase angle method 9.4.1 With voltmeter <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 9.4.2 With phase angle meter 9.4.3 With other instruments <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 10. Insulation resistance tests <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 11. Winding and lead resistance (internal resistance) 12. Excitation test <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 13. Admittance test <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 14. Burden tests 15. Burden measurements <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 16. Specialized situations 16.1 CT in a closed-delta transformer connection 16.2 Generator CTs 16.3 Inter-core coupling check <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | Annex A (informative) Wiring integrity, test switches, and test equipment <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | Annex B (informative) Excitation voltage measurement considerations <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | Annex C (informative) Optical current sensor systems <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | Annex D (informative) Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" IEEE Guide for Field Testing of Relaying Current Transformers<\/b><\/p>\n |