{"id":400514,"date":"2024-10-20T04:50:38","date_gmt":"2024-10-20T04:50:38","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-8802-32021-amd-4-2021\/"},"modified":"2024-10-26T08:38:19","modified_gmt":"2024-10-26T08:38:19","slug":"ieee-8802-32021-amd-4-2021","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-8802-32021-amd-4-2021\/","title":{"rendered":"IEEE 8802-3:2021\/Amd 4-2021"},"content":{"rendered":"

Adoption Standard – Active. This amendment to IEEE Std 802.3-2018 adds Physical Layer (PHY) specifications and management parameters for 50 Gb\/s, 200 Gb\/s, and 400 Gb\/s operation over single-mode fiber with reaches of at least 40 km.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
4<\/td>\nBlank Page <\/td>\n<\/tr>\n
5<\/td>\nTitle page <\/td>\n<\/tr>\n
7<\/td>\nImportant Notices and Disclaimers Concerning IEEE Standards Documents <\/td>\n<\/tr>\n
10<\/td>\nParticipants <\/td>\n<\/tr>\n
13<\/td>\nIntroduction <\/td>\n<\/tr>\n
16<\/td>\nContents <\/td>\n<\/tr>\n
22<\/td>\n1. Introduction
1.4 Definitions <\/td>\n<\/tr>\n
23<\/td>\n30. Management
30.5 Layer management for medium attachment units (MAUs)
30.5.1 MAU managed object class
30.5.1.1 MAU attributes
30.5.1.1.2 aMAUType <\/td>\n<\/tr>\n
24<\/td>\n45. Management Data Input\/Output (MDIO) Interface
45.2 MDIO Interface Registers
45.2.1 PMA\/PMD registers
45.2.1.6 PMA\/PMD control 2 register (Register 1.7) <\/td>\n<\/tr>\n
25<\/td>\n45.2.1.7 PMA\/PMD status 2 register (Register 1.8)
45.2.1.7.4 Transmit fault (1.8.11)
45.2.1.7.5 Receive fault (1.8.10) <\/td>\n<\/tr>\n
26<\/td>\n45.2.1.8 PMD transmit disable register (Register 1.9)
45.2.1.17a 50G PMA\/PMD extended ability register (Register 1.20)
45.2.1.17a.1a 50GBASE-ER ability (1.20.5) <\/td>\n<\/tr>\n
27<\/td>\n45.2.1.20 200G PMA\/PMD extended ability register (Register 1.23)
45.2.1.20.1a 200GBASE-ER4 ability (1.23.6)
45.2.1.20.5 200GBASE-SR4 ability (1.23.2)
45.2.1.20.6 200GBASE-CR4 ability (1.23.1)
45.2.1.20.7 200GBASE-KR4 ability (1.23.0) <\/td>\n<\/tr>\n
28<\/td>\n45.2.1.21 400G PMA\/PMD extended ability register (Register 1.24)
45.2.1.21.1a 400GBASE-ER8 ability (1.24.10)
45.2.1.21b 40G\/100G PMA\/PMD extended ability 2 (Register 1.26) <\/td>\n<\/tr>\n
29<\/td>\n45.2.1.21b.1 100GBASE-SR2 ability (1.26.9)
45.2.1.21b.2 100GBASE-CR2 ability (1.26.8)
45.2.1.21b.3 100GBASE-KR2 ability (1.26.7)
45.2.1.21b.4 100GBASE-DR ability (1.26.3) <\/td>\n<\/tr>\n
30<\/td>\n78. Energy-Efficient Ethernet (EEE)
78.1 Overview
78.1.4 PHY types optionally supporting EEE <\/td>\n<\/tr>\n
31<\/td>\n116. Introduction to 200 Gb\/s and 400 Gb\/s networks
116.1 Overview
116.1.2 Relationship of 200 Gigabit and 400 Gigabit Ethernet to the ISO OSI reference model
116.1.3 Nomenclature <\/td>\n<\/tr>\n
32<\/td>\n116.1.4 Physical Layer signaling systems <\/td>\n<\/tr>\n
33<\/td>\n116.4 Delay constraints <\/td>\n<\/tr>\n
34<\/td>\n121. Physical Medium Dependent (PMD) sublayer and medium, type 200GBASE-DR4
121.7 PMD to MDI optical specifications for 200GBASE-DR4
121.7.1 200GBASE-DR4 transmitter optical specifications <\/td>\n<\/tr>\n
35<\/td>\n121.7.2 200GBASE-DR4 receive optical specifications <\/td>\n<\/tr>\n
36<\/td>\n121.7.3 200GBASE-DR4 illustrative link power budget
121.8 Definition of optical parameters and measurement methods
121.8.1 Test patterns for optical parameters <\/td>\n<\/tr>\n
37<\/td>\n121.8.5 Transmitter and dispersion eye closure for PAM4 (TDECQ)
121.8.5.1 TDECQ conformance test setup
121.8.5.3 TDECQ measurement method
121.8.5.4 TDECQ reference equalizer
121.8.6a Transmitter transition time <\/td>\n<\/tr>\n
38<\/td>\n121.8.8 Receiver sensitivity
121.8.9 Stressed receiver sensitivity
121.8.9.1 Stressed receiver conformance test block diagram <\/td>\n<\/tr>\n
39<\/td>\n121.8.9.2 Stressed receiver conformance test signal characteristics and calibration
121.12 Protocol implementation conformance statement (PICS) proforma for Clause 121, Physical Medium Dependent (PMD) sublayer and medium, type 200GBASE-DR4
121.12.4 PICS proforma tables for Physical Medium Dependent (PMD) sublayer and medium, type 200GBASE-DR4
121.12.4.4 Optical measurement methods <\/td>\n<\/tr>\n
40<\/td>\n122. Physical Medium Dependent (PMD) sublayer and medium, type 200GBASE-FR4, 200GBASE-LR4, 200GBASE-ER4, 400GBASE-FR8, and 400GBASE-LR8, and 400GBASE-ER8
122.1 Overview <\/td>\n<\/tr>\n
42<\/td>\n122.2 Physical Medium Dependent (PMD) service interface
122.3 Delay and Skew
122.3.1 Delay constraints
122.5 PMD functional specifications <\/td>\n<\/tr>\n
43<\/td>\n122.5.1 PMD block diagram
122.5.4 PMD global signal detect function <\/td>\n<\/tr>\n
44<\/td>\n122.5.7 PMD global transmit disable function (optional)
122.5.8 PMD lane-by-lane transmit disable function
122.6 Wavelength-division-multiplexed lane assignments <\/td>\n<\/tr>\n
45<\/td>\n122.7 PMD to MDI optical specifications for 200GBASE-FR4, 200GBASE-LR4, 200GBASE-ER4, 400GBASE-FR8, and 400GBASE-LR8, and 400GBASE-ER8 <\/td>\n<\/tr>\n
46<\/td>\n122.7.1 200GBASE-FR4, 200GBASE-LR4, 200GBASE-ER4, 400GBASE-FR8, and 400GBASE- LR8, and 400GBASE-ER8 transmitter optical specifications <\/td>\n<\/tr>\n
49<\/td>\n122.7.2 200GBASE-FR4, 200GBASE-LR4, 200GBASE-ER4, 400GBASE-FR8, and 400GBASE- LR8, and 400GBASE-ER8 receive optical specifications <\/td>\n<\/tr>\n
51<\/td>\n122.7.3 200GBASE-FR4, 200GBASE-LR4, 200GBASE-ER4, 400GBASE-FR8, and 400GBASE- LR8, and 400GBASE-ER8 illustrative link power budgets <\/td>\n<\/tr>\n
52<\/td>\n122.8 Definition of optical parameters and measurement methods
122.8.1 Test patterns for optical parameters
122.8.2 Wavelength and side mode suppression ratio (SMSR)
122.8.3 Average optical power <\/td>\n<\/tr>\n
53<\/td>\n122.8.4 Outer Optical Modulation Amplitude (OMAouter)
122.8.5 Transmitter and dispersion eye closure for PAM4 (TDECQ)
122.8.5.1 TDECQ conformance test setup <\/td>\n<\/tr>\n
54<\/td>\n122.8.5.2 Channel requirements
122.8.5.3 TDECQ measurement method
122.8.5.4 TDECQ reference equalizer <\/td>\n<\/tr>\n
55<\/td>\n122.8.6 Extinction ratio
122.8.6a Transmitter transition time
122.8.7 Relative intensity noise (RIN17.1OMA, and RIN15.6OMA, and RIN15OMA)
122.8.8 Receiver sensitivity <\/td>\n<\/tr>\n
57<\/td>\n122.8.9 Stressed receiver sensitivity <\/td>\n<\/tr>\n
58<\/td>\n122.8.9.1 Stressed receiver conformance test block diagram
122.8.9.2 Stressed receiver conformance test signal characteristics and calibration
122.9 Safety, installation, environment, and labeling
122.9.2 Laser safety <\/td>\n<\/tr>\n
59<\/td>\n122.9.4 Environment
122.9.5 Electromagnetic emission
122.9.7 PMD labeling requirements
122.10 Fiber optic cabling model <\/td>\n<\/tr>\n
60<\/td>\n122.11 Characteristics of the fiber optic cabling (channel)
122.11.1 Optical fiber cable
122.11.2 Optical fiber connection
122.11.2.1 Connection insertion loss <\/td>\n<\/tr>\n
61<\/td>\n122.11.2.2 Maximum discrete reflectance
122.11.3 Medium Dependent Interface (MDI) requirements
122.11a Requirements for interoperation between 200GBASE-ER4 and 200GBASE-LR4 <\/td>\n<\/tr>\n
62<\/td>\n122.11b Requirements for interoperation between 400GBASE-ER8 and 400GBASE-FR8
122.11c Requirements for interoperation between 400GBASE-ER8 and 400GBASE-LR8 <\/td>\n<\/tr>\n
63<\/td>\n122.12 Protocol implementation conformance statement (PICS) proforma for Clause 122, Physical Medium Dependent (PMD) sublayer and medium, type 200GBASE-FR4, 200GBASE-LR4, 200GBASE-ER4, 400GBASE-FR8, and 400GBASE-LR8, and 400GBASE-ER8
122.12.1 Introduction
122.12.2 Identification
122.12.2.2 Protocol summary <\/td>\n<\/tr>\n
64<\/td>\n122.12.3 Major capabilities\/options
122.12.4 PICS proforma tables for Physical Medium Dependent (PMD) sublayer and medium, type 200GBASE-FR4, 200GBASE-LR4, 200GBASE-ER4, 400GBASE-FR8, and 400GBASE-LR8, and 400GBASE-ER8 <\/td>\n<\/tr>\n
65<\/td>\n122.12.4.4a PMD to MDI optical specifications for 200GBASE-ER4
122.12.4.6a PMD to MDI optical specifications for 400GBASE-ER8
122.12.4.7 Optical measurement methods
122.12.4.8 Environmental specifications <\/td>\n<\/tr>\n
66<\/td>\n124. Physical Medium Dependent (PMD) sublayer and medium, type 400GBASE-DR4
124.7 PMD to MDI optical specifications for 400GBASE-DR4
124.7.1 400GBASE-DR4 transmitter optical specifications <\/td>\n<\/tr>\n
67<\/td>\n124.7.2 400GBASE-DR4 receive optical specifications
124.8 Definition of optical parameters and measurement methods
124.8.1 Test patterns for optical parameters <\/td>\n<\/tr>\n
68<\/td>\n124.8.5 Transmitter and dispersion eye closure for PAM4 (TDECQ)
124.8.6a Transmitter transition time <\/td>\n<\/tr>\n
69<\/td>\n124.8.9 Stressed receiver sensitivity
124.12 Protocol implementation conformance statement (PICS) proforma for Clause 124, Physical Medium Dependent (PMD) sublayer and medium, type 400GBASE-DR4
124.12.4 PICS proforma tables for Physical Medium Dependent (PMD) sublayer and medium, type 400GBASE-DR4
124.12.4.4 Optical measurement methods <\/td>\n<\/tr>\n
70<\/td>\n131. Introduction to 50 Gb\/s networks
131.1 Overview
131.1.2 Relationship of 50 Gigabit Ethernet to the ISO OSI reference model
131.1.3 Nomenclature
131.1.4 Physical Layer signaling systems <\/td>\n<\/tr>\n
71<\/td>\n131.4 Delay constraints <\/td>\n<\/tr>\n
72<\/td>\n138. Physical Medium Dependent (PMD) sublayer and medium, type 50GBASE-SR, 100GBASE-SR2, 200GBASE-SR4
138.8 Definition of optical parameters and measurement methods
138.8.5 Transmitter and dispersion eye closure for PAM4 (TDECQ)
138.8.10 Stressed receiver sensitivity <\/td>\n<\/tr>\n
73<\/td>\n139. Physical Medium Dependent (PMD) sublayer and medium, type 50GBASE-FR, and 50GBASE-LR, and 50GBASE-ER
139.1 Overview <\/td>\n<\/tr>\n
74<\/td>\n139.2 Physical Medium Dependent (PMD) service interface <\/td>\n<\/tr>\n
75<\/td>\n139.3 Delay and Skew
139.3.1 Delay constraints
139.5 PMD functional specifications
139.5.1 PMD block diagram
139.6 PMD to MDI optical specifications for 50GBASE-FR, and 50GBASE-LR, and 50GBASE-ER <\/td>\n<\/tr>\n
76<\/td>\n139.6.1 50GBASE-FR, and 50GBASE-LR, and 50GBASE-ER transmitter optical specifications <\/td>\n<\/tr>\n
77<\/td>\n139.6.2 50GBASE-FR, and 50GBASE-LR, and 50GBASE-ER receive optical specifications <\/td>\n<\/tr>\n
78<\/td>\n139.6.3 50GBASE-FR, and 50GBASE-LR, and 50GBASE-ER illustrative link power budgets <\/td>\n<\/tr>\n
79<\/td>\n139.7 Definition of optical parameters and measurement methods
139.7.1 Test patterns for optical parameters
139.7.2 Wavelength and side-mode suppression ratio (SMSR)
139.7.3 Average optical power <\/td>\n<\/tr>\n
80<\/td>\n139.7.4 Outer Optical Modulation Amplitude (OMAouter)
139.7.5 Transmitter and dispersion eye closure for PAM4 (TDECQ)
139.7.5.2 Channel requirements
139.7.5.3 TDECQ measurement method <\/td>\n<\/tr>\n
81<\/td>\n139.7.5.4 TDECQ reference equalizer
139.7.6 Extinction ratio
139.7.8 Relative intensity noise (RIN17.1OMA, and RIN15.6OMA, and RIN15OMA)
139.7.9 Receiver sensitivity <\/td>\n<\/tr>\n
82<\/td>\n139.7.10 Stressed receiver sensitivity
139.7.10.2 Stressed receiver conformance test signal characteristics and calibration <\/td>\n<\/tr>\n
83<\/td>\n139.8 Safety, installation, environment, and labeling
139.8.2 Laser safety
139.8.4 Environment
139.8.5 Electromagnetic emission <\/td>\n<\/tr>\n
84<\/td>\n139.9 Fiber optic cabling model
139.10 Characteristics of the fiber optic cabling (channel)
139.10.1 Optical fiber cable <\/td>\n<\/tr>\n
85<\/td>\n139.10.2 Optical fiber connection
139.10.2.1 Connection insertion loss
139.10.2.2 Maximum discrete reflectance
139.10.3 Medium Dependent Interface (MDI) requirements <\/td>\n<\/tr>\n
86<\/td>\n139.10a Requirements for interoperation between 50GBASE-ER and 50GBASE-FR
139.10b Requirements for interoperation between 50GBASE-ER and 50GBASE-LR
139.11 Protocol implementation conformance statement (PICS) proforma for Clause 139, Physical Medium Dependent (PMD) sublayer and medium, type 50GBASE-FR, and 50GBASE-LR, and 50GBASE-ER <\/td>\n<\/tr>\n
87<\/td>\n139.11.1 Introduction
139.11.2 Identification
139.11.2.2 Protocol summary
139.11.3 Major capabilities\/options <\/td>\n<\/tr>\n
88<\/td>\n139.11.4 PICS proforma tables for Physical Medium Dependent (PMD) sublayer and medium, type 50GBASE-FR, and 50GBASE-LR, and 50GBASE-ER
139.11.4.4a PMD to MDI optical specifications for 50GBASE-ER <\/td>\n<\/tr>\n
89<\/td>\n140. Physical Medium Dependent (PMD) sublayer and medium, type 100GBASE-DR
140.7 Definition of optical parameters and measurement methods
140.7.5 Transmitter and dispersion eye closure for PAM4 (TDECQ)
140.7.10 Stressed receiver sensitivity <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

IEEE\/ISO\/IEC Telecommunications and exchange between information technology systems — Requirements for local and metropolitan area networks — Part 3: Standard for Ethernet
\nAMENDMENT 4: Physical layers and management parameters for 50 Gb\/s,200 Gb\/s, and 400 Gb\/s operation over single-mode fiber<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
IEEE<\/b><\/a><\/td>\n2021<\/td>\n90<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":400521,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2644],"product_tag":[],"class_list":{"0":"post-400514","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ieee","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/400514","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/400521"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=400514"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=400514"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=400514"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}