{"id":374529,"date":"2024-10-20T02:39:03","date_gmt":"2024-10-20T02:39:03","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-iec-630852021\/"},"modified":"2024-10-26T04:36:57","modified_gmt":"2024-10-26T04:36:57","slug":"bs-iec-630852021","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-iec-630852021\/","title":{"rendered":"BS IEC 63085:2021"},"content":{"rendered":"
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
2<\/td>\n | undefined <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | English CONTENTS <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | FOREWORD <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | INTRODUCTION <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 1 Scope 2 Normative references <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 4 Requirements 4.1 Structure and appearance 4.2 Functions 4.2.1 Alarm 4.2.2 Displayed data 4.2.3 Recording and storage of identification data <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 4.2.4 Error diagnostics and self-verification 4.2.5 Access control software 4.3 Performance 4.3.1 Testing conditions Tables Table 1 \u2013 Reference condition and standard test conditions <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 4.3.2 Time for single inspection 4.3.3 Requirements for minimum volume of liquid to be inspected 4.3.4 Requirements for container wall thickness Table 2 \u2013 Key apparatus for tests and technical requirements <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 4.3.5 Requirements for container wall transparency Figures Figure 1 \u2013 Test on container wall thickness <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 4.3.6 Requirements for detectable spectral range 4.3.7 Reproducibility of identification result Figure 2 \u2013 Test on container wall transparency <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 4.3.8 Selectivity of substance identification Table 3 \u2013 Reproducibility test results table <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 4.4 Laser safety 4.4.1 General 4.5 Electrical safety 4.5.1 Main power connection <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 4.5.2 Stability at mains power supply 4.5.3 Battery connection 4.5.4 Stability to battery charge level 4.6 Mechanical stability 4.6.1 General <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 4.6.2 Requirements 4.6.3 Test method 4.7 Environmental requirements 4.7.1 Environmental suitability test 4.7.2 Mechanical vibration testing Table 4 \u2013 Ambient requirements <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 4.8 Electromagnetic compatibility 4.8.1 Immunity testing Table 5 \u2013 Tests and requirements for mechanical stability <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 4.8.2 Emission test 5 Marking and documentation 5.1 Raman analyzer marking 5.2 Documentation <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | Annex A (informative)Raman spectra of test samples A.1 Raman spectrum of test samples 1 and 2 Figure A.1 \u2013 Raman spectrum of test samples 1 and 2 (cyclohexane) with four reference peaks (384 cm\u22121 \u00b1 2 cm\u22121, 801 cm\u22121 \u00b1 2 cm\u22121, 1 444 cm\u22121 \u00b1 2 cm\u22121, 2 853 cm\u22121 \u00b1 2 cm\u22121) to verify the spectral range of 300 cm\u22121 to 3 000 cm\u22121 <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | A.2 Raman spectrum of test sample 3 Figure A.2 \u2013 Raman spectrum of test sample 3 (water) with the reference band to verify the spectral range 3 000 cm\u22121 to 3 600 cm\u22121 <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | A.3 Raman spectrum of test sample 4 Figure A.3 \u2013 Raman spectrum of test sample 4 (10 % ethanol in water) with three reference peaks of ethanol in water (879 cm\u22121 \u00b1 2 cm\u22121, 1 455 cm\u22121 \u00b1 2 cm\u22121,2 935 cm\u22121 \u00b1 2 cm\u22121) and the reference band of water in the spectral range3 000 cm\u22121 to 3 600 cm\u22121 <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | A.4 Raman spectrum of test sample 5 Figure A.4 \u2013 Raman spectrum of test sample 5 (50 % methanol + 50 % ethanol) <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | A.5 Raman spectrum of test sample 6 Figure A.5 \u2013 Raman spectrum of test sample 6(33,3 % methanol + 33,3 % ethanol + 33,3 % isopropanol) <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Radiation protection instrumentation. System of spectral identification of liquids in transparent and semitransparent containers (Raman systems)<\/b><\/p>\n |