{"id":272959,"date":"2024-10-19T18:19:28","date_gmt":"2024-10-19T18:19:28","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-16430-22014\/"},"modified":"2024-10-25T14:40:07","modified_gmt":"2024-10-25T14:40:07","slug":"bs-en-16430-22014","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-16430-22014\/","title":{"rendered":"BS EN 16430-2:2014"},"content":{"rendered":"
This European Standard applies to the thermal output testing of fan assisted radiators, convectors and trench convectors which are factory assembled or kits, i.e.<\/p>\n
fan assisted radiators and convectors, provided the heater has a dedicated fan or fans;<\/p>\n<\/li>\n
trench convectors with and without fan(s), provided the heater and the fan(s) are dedicated;<\/p>\n<\/li>\n
ventilation radiators and convectors.<\/p>\n<\/li>\n<\/ul>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
4<\/td>\n | Contents Page <\/td>\n<\/tr>\n | ||||||
5<\/td>\n | Foreword <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | 1 Scope 2 Normative references 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | 4 Radiators and convectors with fan(s) and trench convectors with and without fan(s) 4.1 Preparation of the closed test room 4.1.1 Trench convectors <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | 4.1.2 Fan assisted radiators and wall mounted convectors <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 4.2 Test procedure 4.2.1 Scope of testing 4.2.2 Determination of the thermal output 4.2.2.1 General <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 4.2.2.2 Influence of mass flow on the characteristic curve 4.2.2.3 Fan assisted radiators and convectors <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 4.3 Test report <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 5 Ventilation radiators and trench convectors 5.1 Design 5.1.1 Wall mounted radiators 5.1.2 Trench convectors <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 5.2 Thermal output testing for ventilation radiators and trench convectors <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 5.3 Test facilities 5.3.1 General <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 5.3.2 Ventilation facility <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 5.4 Test method 5.5 Test 5.5.1 General 5.5.2 Test structure 5.5.3 Selection of heating appliances to be tested 5.5.4 Standard reference point and standard water flow rate <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 5.5.5 Test temperatures and test scope 5.5.6 Steady state conditions <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 5.5.7 Correction due to the air pressure 5.5.8 Test results \u2013 characteristic curves field <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 5.5.9 Standard thermal output 5.5.9.1 General 5.5.9.2 Determining the thermal output \u03a6ZL to the primary air flow <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 5.5.9.3 Determining the thermal output of the ventilation radiator <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 5.6 Test report 5.6.1 General 5.6.2 Data <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Fan assisted radiators, convectors and trench convectors – Test method and rating for thermal output<\/b><\/p>\n |