{"id":247243,"date":"2024-10-19T16:16:13","date_gmt":"2024-10-19T16:16:13","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-60794-3-122013\/"},"modified":"2024-10-25T11:22:23","modified_gmt":"2024-10-25T11:22:23","slug":"bs-en-60794-3-122013","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-60794-3-122013\/","title":{"rendered":"BS EN 60794-3-12:2013"},"content":{"rendered":"
This part of IEC 60794 is a detailed specification for duct and directly buried optical telecommunication cables for use in premises cabling to ensure compatibility with ISO\/IEC 11801 and ISO\/IEC 24702. Those standards have requirements to ensure that models work for generic cabling and system performances. Values in this standard support these models.<\/p>\n
The requirements of the family specification IEC 60794-3-10 are applicable to cables covered by this standard. Particular requirements detailed in Clause 4 of this standard either define a specific option relative to the requirements of IEC 60794-3-10 or define additional requirements.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
6<\/td>\n | English CONTENTS <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | 1 Scope 2 Normative references <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | 3 General requirements 4 Particular requirements 4.1 General 4.2 MICE (mechanical, ingress, climatic and chemical and electromagnetic) characteristics <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 4.3 Transmission requirements 4.3.1 Attenuation of cabled fibre 4.3.2 Fibre bandwidth requirements Table 1 \u2013 Multimode maximum cable attenuation coefficient (dB\/km) Table 2 \u2013 Single-mode maximum cable attenuation coefficient (dB\/km) <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 4.3.3 Polarization mode dispersion (PMD) requirements Table 3 \u2013 Minimum multimode fibre bandwidth (MHz x km) <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Optical fibre cables – Outdoor cables. Detailed specification for duct and directly buried optical telecommunication cables for use in premises cabling<\/b><\/p>\n |