BSI 23/30480405 DC 2023
$13.70
BS EN IEC 62192 Live working. Insulating ropes
Published By | Publication Date | Number of Pages |
BSI | 2023 | 41 |
PDF Catalog
PDF Pages | PDF Title |
---|---|
7 | FOREWORD |
10 | INTRODUCTION |
11 | 1 Scope 2 Normative references 3 Terms and definitions 3.1 Terms and definitions |
13 | 3.2 Abbreviated terms, symbols, and units 4 Requirements 4.1 General |
14 | 4.2 Physical and dimensional 4.2.1 General 4.2.2 Physical 4.2.3 Dimensional 4.3 Electrical 4.4 Mechanical 4.5 Marking |
15 | 4.6 Instructions for use, maintenance, and care 5 Tests 5.1 General |
16 | 5.2 Atmospheric conditions 5.3 Visual verification and dimensional checking 5.3.1 Visual verification 5.3.2 Dimensional check 5.4 Electrical tests 5.4.1 General |
17 | 5.4.2 Leakage current under dry conditions – Category 1 insulating rope 5.4.2.1 Test Set-up for both dry and wet conditions |
19 | 5.4.2.2 Test procedure for dry conditions |
22 | 5.4.2.3 Test acceptance criteria |
23 | 5.4.3 Leakage current after water conditioning – Category 1 Insulating Rope 5.4.3.1 Conditioning the insulating rope 5.4.3.1.1 Category 1 insulating rope 5.4.3.2 Test set-up 5.4.3.2.1 Category 1 insulating rope 5.4.3.3 Electrical test procedure 5.4.3.3.1 Category 1 Insulating Rope 5.4.3.4 Acceptance Criteria 5.4.3.4.1 Category 1 Insulating Rope |
24 | 5.4.3.5 Determination of break strength after wet electrical test 5.5 Durability of marking 5.6 Verification of the required instructions for use 6 Method of assessment of defects and verification of performance applicable to insulating ropes during the production phase 6.1 General 6.2 Verification method for insulating ropes during the production phase 6.3 Alternative means to test insulating ropes during the production phase |
25 | 7 Test Report 8 Modifications |
26 | Annex A (normative) Suitable for live working; double triangle (IEC 60417-5216 (2002-10)) |
27 | Annex B (normative) Chronology of type tests |
28 | Annex C (informative) Test Requirements and Criterion Overview for Type 1 and Category 2 Insulating Ropes |
29 | Annex D (normative) Classification of defects |
30 | Annex E (informative) Rationale for the classification of defects |
31 | Annex F (normative) Marking to identify insulating rope |
32 | Annex G (informative) Summary Report of Type Testing Example |
33 | Annex H (informative) Category 2 insulating rope H.1 General H.1.1 Tests for Category 2 H.1.2 Leakage current under dry conditions – Category 2 Insulating Rope H.1.3 Leakage current After water conditioning H.1.3.1 Category 2 Insulating Rope H.1.3.2 Test set-up H.1.3.2.1 Category 2 Insulating Rope H.1.4 Electrical Test Procedure H.1.4.1 Category 2 Insulating Rope |
34 | H.1.4.2 Acceptable criteria H.1.4.2.1 Category 2 Insulating Rope H.1.5 Determination of break strength after wet electrical test |
35 | Annex I (informative) Termination |
36 | Annex J (informative) In-service care and periodic testing J.1 In-service care and periodic testing – General J.2 Identification J.3 Storage J.3.1 In the field J.3.2 In the storage room |
37 | J.4 Handling J.5 Periodic testing J.5.1 Inspection in the field before each use J.5.2 Periodic high voltage testing |
38 | J.6 Application safety factor and working load limit |
39 | J.7 Use with capstans or pulleys J.8 Cleaning, repair, and recycling |
40 | J.9 Retirement |
41 | Bibliography |