Gypsum board thermal/acoustic insulation composite panels. Definitions, requirements and test methods

Published By Publication Date Number of Pages
BSI 2014 36
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This European Standard specifies the characteristics and performance of thermal/acoustic insulation composite panels made of an insulating material laminated to gypsum boards for which the main intended use is the internal insulation (thermal and/or acoustic) of walls. They are attached with adhesives or by mechanical fixings to vertical solid backgrounds and by mechanical fixings to wood or metal framing with the gypsum board face exposed. The method of fixing and jointing should ensure that the insulating material is not exposed in its normal application.

This European Standard covers the following performance characteristics: reaction to fire, fire resistance, water vapour permeability, flexural strength, impact resistance, direct airborne sound insulation and thermal resistance to be measured according to the corresponding European test methods.

It provides for the assessment and verification of constancy of performance of the products to this European Standard.

This European Standard covers also additional technical characteristics that are of importance for the use and acceptance of the product by the construction industry.

PDF Catalog

PDF Pages PDF Title
6 Foreword
7 1 Scope
2 Normative references
8 3 Terms, definitions, symbols, abbreviations and classification
3.1 Terms and definitions of the product
3.2 General terms
9 3.3 Symbols and abbreviations
Table 1 — Symbols and abbreviations
3.4 Classification
4 Requirements
4.1 General
10 4.2 Fire behaviour
4.2.1 Reaction to fire
4.2.2 Fire resistance
4.3 Water vapour permeability (expressed as water vapour resistance factor)
4.4 Flexural strength
4.5 Impact resistance
4.6 Direct airborne sound insulation
4.7 Acoustic absorption
11 4.8 Thermal resistance of the panel
4.9 Dimensions and tolerances
4.10 Offset
4.11 Flatness of the composite
4.12 Adhesion/cohesion of the insulating material
4.13 Dangerous substances
12 5 Test methods
5.1 Sampling
5.2 Dimensional measurements
5.2.1 Thickness
5.2.1.1 Principle
5.2.1.2 Apparatus
5.2.1.3 Procedure
5.2.1.4 Expression of results
Figure 1 — Measurement of thickness
13 5.3 Determination of the offset
5.3.1 Principle
In the case of sandwich panels:
5.3.2 Apparatus
5.3.3 Procedure
Dimensions in millimetres
14 Figure 2 — Measurement of offset
5.3.4 Expression of results
5.4 Determination of the adhesion/cohesion of the insulating material
5.4.1 Principle
5.4.2 Apparatus
15 Figure 3 — Example of adhesion test apparatus
16 5.4.3 Procedure
Figure 4 — Adhesion test – Position of the specimens
5.4.4 Expression of results
5.5 Determination of the flatness of the composite
5.5.1 Principle
17 5.5.2 Apparatus and specimens
5.5.3 Procedure
5.5.4 Expression of results
6 Assessment and verification of constancy of performance – AVCP
6.1 General
6.2 Type testing
6.2.1 General
6.2.2 Determination of the product type
18 6.2.3 Further type testing
6.3 Factory production control (FPC)
6.3.1 General
6.3.2 Personnel
6.3.3 Equipment
6.3.3.1 Testing
6.3.3.2 Manufacturing
19 6.3.4 Raw materials and components
6.3.5 Product testing and evaluation
6.3.6 Traceability and marking
6.3.7 Non-complying products
6.3.8 Corrective action
6.3.9 Other test methods
7 Designation of composite panels
20 8 Marking, labelling and packaging
21 Annex A (informative) Sampling procedure for testing
A.1 General
A.2 Sampling procedure
A.2.1 General
A.2.2 Random sampling0F )
A.2.3 Representative sampling
A.2.3.1 General
A.2.3.2 Sampling from a stack
22 A.2.3.3 Sampling from a consignment formed of banded or wrapped packs
23 Annex B (normative) Mounting and fixing in the test according to EN 13823 (SBI test)
B.1 Mounting and fixing of the composite panels
24 Figure B.1 — Mounting of the composites and fixing them to the substrate – Distribution of the dabs
Figure B.2 — Mounting of the composites and fixing them to the substrate – Section
25 Annex ZA (informative) Clauses of this European Standard addressing provisions of the EU Construction Products Regulation
ZA.1 Scope and relevant characteristics
Table ZA.1 — Relevant clauses for gypsum board thermal/acoustic insulation composite panels and intended use
26 ZA.2 Procedure for AVCP of gypsum board thermal/acoustic composite panels
ZA.2.1 Systems of AVCP
Table ZA.2 — Systems of AVCP
27 Table ZA.3.1 — Assignment of AVCP tasks for gypsum board thermal/acoustic insulation composite panels under system 1 (for reaction to fire classes A1(1), A2 (1), B (1),C (1))
28 Table ZA.3.2 — Assignment of AVCP tasks for gypsum board thermal/acoustic insulation composite panels under system 3 (for reaction to fire classes A1(2), A2(2), B (2), C(2), D, E)
Table ZA.3.3 — Assignment of AVCP tasks for gypsum board thermal/acoustic insulation composite panels under system 4 (for reaction to fire classes (A1 to E) (3), F)
ZA.2.2 Declaration of performance (DoP)
ZA.2.2.1 General
29 ZA.2.2.2 Content
30 ZA.2.2.3 Example of DoP
31 ZA.3 CE marking and labelling
32 Figure ZA.1 — Example CE marking information of products under AVCP system 3 on the accompanying label, or on the packaging or on the accompanying commercial documents
33 Figure ZA.2 — Example CE marking information of products under AVCP system 3 on the product
34 Bibliography