{"id":80714,"date":"2024-10-17T18:47:16","date_gmt":"2024-10-17T18:47:16","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-c57-119-2002\/"},"modified":"2024-10-24T19:44:29","modified_gmt":"2024-10-24T19:44:29","slug":"ieee-c57-119-2002","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-c57-119-2002\/","title":{"rendered":"IEEE C57.119 2002"},"content":{"rendered":"
New IEEE Standard – Active. Reaffirmed 2008. Recommendations are made, where possible, regarding the performance and evaluation of temperature rise tests on oil-immersed power transformers beyond nameplate ratings. The intent is to assist power transformer manufacturers, and the ultimate users, in evaluating thermal performance of the transformers under varying loads.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
2<\/td>\n | Title Page <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
5<\/td>\n | Participants <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | CONTENTS <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 1. Overview 1.1 Scope 1.2 Purpose <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 2. References <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 3. Definitions and symbols 3.1 Definitions <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 3.2 Symbols <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 4. General 4.1 Preliminary evaluation 4.2 Cooling equipment operation 5. Precautions <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 5.1 Thermal degradation 5.2 Other factors limiting loading 5.3 Monitoring of test results <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 5.4 Maximum temperatures 6. Monitored data 6.1 Ambient air temperature 6.2 Oil temperatures 6.3 Other temperatures 6.4 Currents 7. Recorded data 7.1 Losses <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 7.2 Temperature indicator readings 7.3 Tank surface and other temperatures 7.4 Oil levels 8. Oil samples 9. Test procedure for determining the thermal characteristics of oil-immersed power transformers <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 9.1 Tap position and connection 9.2 Number of tests 9.3 Applied test currents 9.4 Discontinued tests <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 9.5 Temperature rise test at rated load 9.6 Temperature rise test at reduced load <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 9.7 Temperature rise test at load beyond nameplate rating 9.8 Evaluation of thermal data <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 9.9 Evaluation of other data 10. Test procedure for performing load cycle temperature rise tests 10.1 Recommended prior tests 10.2 Information specified by user <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 10.3 Determination of load cycle <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | 10.4 Preparatory calculations 10.5 Data recorded 10.6 Test procedure <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | 10.7 Interrupted test <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | 10.8 Assessment of transformer performance 11. Integrated test procedure for determining thermal characteristics and for performing load cyc… 11.1 Load cycle simulation 11.2 Preliminary evaluation <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | 11.3 Test procedure 11.4 Initial test 11.5 Conditioning load 11.6 Beyond maximum nameplate test 11.7 Final test <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | Annex A \n(normative) \nLoading guide equations <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | Annex B \n(informative) \nTutorial <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | Annex C \n(informative) \nHottest spot measurements using direct reading \u2022ber optics \ntemperature measurements <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | Annex D \n(informative) \nBibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" IEEE Recommended Practice for Performing Temperature Rise Tests on Oil-Immersed Power Transformers at Loads Beyond Nameplate Ratings<\/b><\/p>\n |