{"id":496708,"date":"2024-11-05T13:00:32","date_gmt":"2024-11-05T13:00:32","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/as-4747-62013\/"},"modified":"2024-11-05T13:00:32","modified_gmt":"2024-11-05T13:00:32","slug":"as-4747-62013","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/as\/as-4747-62013\/","title":{"rendered":"AS 4747.6:2013"},"content":{"rendered":"

Sets out requirements for water meters for use in non-urban applications in open channel and part-filled applications. It primarily applies to metering for irrigation water. <\/p>\n

Scope<\/b><\/p>\n

This Standard sets out requirements for the installation and commissioning of meters complying with NMI M11-1 and AS 4747.3, for use in non-urban applications in open channel and part-filled pipe applications. The Standard principally covers metering for irrigation water.
Two types of meter installations are covered in this Standard, as follows:
(a) A \u2018self-contained unit\u2019\u2014a meter that defines its own geometry, is able to be pattern-approved as a complete water meter, calibrated upon assembly and supplied by a single supplier.
(b) A \u2018modular metering system\u2019\u2014a device or group of instruments (which may be supplied as a pattern-approved metering system) that does not define the installation geometry and requires configuration after installation.
NOTES:
1 The requirements for these types of meters to demonstrate compliance with this Standard, and hence with the National Framework are set out and illustrated in Section 7 of AS 4747.3.
2 Meters with undefined or variable channel are not covered by this Standard.
In this Standard, a meter installation is considered to include\u2014
(i) the meter, its indicating device and all ancillary equipment; and
(ii) the upstream and downstream pipe or emplacement that may have a material effect on the meter unit.
The Standard covers meters that operate under the following conditions:
(A) Open channels.
(B) Working water temperature range of 0.1\u00b0C to 30\u00b0C. The maximum admissible temperature is 50\u00b0C, which is the limiting condition for the meter.
(C) Ambient temperature range of ?5\u00b0C to 55\u00b0C.
(D) Ambient humidity range of 0% to 100% except for remote indicating devices where the range is 0% to 93%.<\/p>\n","protected":false},"excerpt":{"rendered":"

Meters for non-urban water supply-Installation and commissioning of open channel meters<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
AS<\/b><\/a><\/td>\n2013-02-21<\/td>\n21<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":496721,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[212,259,2633],"product_tag":[],"class_list":{"0":"post-496708","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-13-060-20","7":"product_cat-17-060","8":"product_cat-as","10":"first","11":"instock","12":"sold-individually","13":"shipping-taxable","14":"purchasable","15":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/496708","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/496721"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=496708"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=496708"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=496708"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}