{"id":465397,"date":"2024-10-20T10:40:21","date_gmt":"2024-10-20T10:40:21","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-c37-122-2-2022-4\/"},"modified":"2024-10-26T19:41:31","modified_gmt":"2024-10-26T19:41:31","slug":"ieee-c37-122-2-2022-4","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-c37-122-2-2022-4\/","title":{"rendered":"IEEE C37.122.2-2022"},"content":{"rendered":"
Revision Standard – Active. Guidance for technical requirements for the design, fabrication, testing, and installation of indoor gas-insulated substations (GIS) 1 kV up to 52 kV is provided in this standard. Parameters to be supplied by the purchaser are suggested and technical requirements for the design, fabrication, testing, and installations to be furnished by the manufacturer are established.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | IEEE Std C37.122.2\u2122-2022 Front cover <\/td>\n<\/tr>\n | ||||||
2<\/td>\n | Title page <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | Important Notices and Disclaimers Concerning IEEE Standards Documents <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | Participants <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | Contents <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 1.\u2002Overview 1.1\u2002Scope 1.2\u2002Word usage <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 2.\u2002Normative references <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 3.\u2002Definitions <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 4.\u2002Service conditions 4.1\u2002Normal service conditions 4.2\u2002Special (unusual) service conditions for both indoor and outdoor switchgear 5.\u2002Planning guidelines for GIS equipment 1 kV up to 52 kV 5.1\u2002Planning <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 5.2\u2002Specification <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | 6.\u2002Installation, operation, and maintenance guidelines 6.1\u2002Safety <\/td>\n<\/tr>\n | ||||||
40<\/td>\n | 6.2\u2002Transport, equipment handling, storage, and installation <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | 6.3\u2002Gas handling <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | 6.4\u2002Site work <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | 6.5\u2002Inspection, maintenance, and repair 6.6\u2002Training 6.7\u2002Refilling and repair <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | 7.\u2002Guidelines for testing procedures 7.1\u2002Design tests <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | 7.2\u2002Production tests 7.3\u2002Conformance tests (optional) <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | 7.4\u2002Commissioning tests 8.\u2002Guidelines for Decommissioning (End of Life) 8.1\u2002Safety <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | 8.2\u2002Gas disposal 8.3\u2002Removal from site 8.4\u2002Final disposal <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | 9.\u2002Documentation <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | Annex\u00a0A (informative) Sequence of operation of equipment qualified using IEEE\u00a0Std\u00a0C37.20.9 A.1\u2002Sequence of operations for typical applications on feeder circuits <\/td>\n<\/tr>\n | ||||||
50<\/td>\n | A.2\u2002Sequence of operations for main bus grounding on sectionalized bus arrangements <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | Annex\u00a0B (informative) Characteristics of gases and gas mixtures B.1\u2002General B.2\u2002General characteristics of SF6 B.3\u2002List of replacement alternative gases for SF6 <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | Annex\u00a0C (informative) Bibliography <\/td>\n<\/tr>\n | ||||||