{"id":420904,"date":"2024-10-20T06:33:27","date_gmt":"2024-10-20T06:33:27","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-iec-630042015-2\/"},"modified":"2024-10-26T12:16:23","modified_gmt":"2024-10-26T12:16:23","slug":"bs-iec-630042015-2","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-iec-630042015-2\/","title":{"rendered":"BS IEC 63004:2015"},"content":{"rendered":"
The scope of this standard is the development of a common receiver fixture interface (RFI) specification that is based upon available commercial standards integrated under a common open architecture<\/i>. This mechanical\/electrical interface is intended to serve government\/commercial interest for applications in test, system integration, manufacturing, monitoring, and other functional requirements that demand large contact densities and quick-disconnect mechanical operation.<\/p>\n Standard for receiver fixture interface<\/b><\/p>\nPDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 4<\/td>\n CONTENTS <\/td>\n<\/tr>\n \n 14<\/td>\n 1. Overview
1.1 Scope
1.2 Purpose
1.3 Background <\/td>\n<\/tr>\n\n 15<\/td>\n 1.4 Annexes overview
2. Normative references <\/td>\n<\/tr>\n\n 19<\/td>\n 2.1 Conventions <\/td>\n<\/tr>\n \n 20<\/td>\n 3. Definitions and special terms <\/td>\n<\/tr>\n \n 22<\/td>\n 3.1 Special terms <\/td>\n<\/tr>\n \n 23<\/td>\n 4. Qualification requirements
4.1 Responsibility for inspection <\/td>\n<\/tr>\n\n 24<\/td>\n 4.2 General requirements <\/td>\n<\/tr>\n \n 27<\/td>\n 4.3 Qualification inspections
4.4 Inspection conditions <\/td>\n<\/tr>\n\n 28<\/td>\n 4.5 Qualification inspection <\/td>\n<\/tr>\n \n 29<\/td>\n 4.6 Method of examination and test <\/td>\n<\/tr>\n \n 39<\/td>\n 5. Framework specification
5.1 Framework specification introduction
5.2 Framework general specification <\/td>\n<\/tr>\n\n 43<\/td>\n 5.3 Materials
5.4 Restricted materials
5.5 Dissimilar metals
5.6 Workmanship
5.7 Design and construction <\/td>\n<\/tr>\n\n 44<\/td>\n 5.8 Framework assembly <\/td>\n<\/tr>\n \n 61<\/td>\n 5.9 Framework alignment\/keying cavities <\/td>\n<\/tr>\n \n 63<\/td>\n 5.10 Framework ball-lock mechanism <\/td>\n<\/tr>\n \n 64<\/td>\n 5.11 Framework ball-lock\/safety-lock pin devices <\/td>\n<\/tr>\n \n 65<\/td>\n 5.12 Framework protective cover
5.13 Method of mounting <\/td>\n<\/tr>\n\n 67<\/td>\n 5.14 Interchangeability
5.15 Framework stroke <\/td>\n<\/tr>\n\n 69<\/td>\n 5.16 Framework engagement and separation forces
5.17 Framework fixture support weight rating
5.18 Electrical conditional requirements <\/td>\n<\/tr>\n\n 70<\/td>\n 5.19 Framework durability
5.20 Oversize fixture framework
5.21 Environmental requirements <\/td>\n<\/tr>\n\n 72<\/td>\n 5.22 Auxiliary parts
5.23 Riveting, upsetting, and spinning over
6. Connector module specification
6.1 Connector module specification introduction <\/td>\n<\/tr>\n\n 73<\/td>\n 6.2 Connector specification system
6.3 Quality
6.4 General and specific connector contact specification relationships <\/td>\n<\/tr>\n\n 74<\/td>\n 6.5 Materials <\/td>\n<\/tr>\n \n 75<\/td>\n 6.6 Reference materials, platings, and processes
6.7 Design and construction
6.8 Connector assembly <\/td>\n<\/tr>\n\n 77<\/td>\n 6.9 Interchangeability <\/td>\n<\/tr>\n \n 78<\/td>\n 6.10 Oversized pin exclusion test <\/td>\n<\/tr>\n \n 79<\/td>\n 6.11 Contact engagement and separation forces
6.12 Connector mating and unmating <\/td>\n<\/tr>\n\n 80<\/td>\n 6.13 Contact rating
6.14 Contact resistance
6.15 Contact retention <\/td>\n<\/tr>\n\n 81<\/td>\n 6.16 Dielectric withstanding voltage
6.17 Signal low-level circuit
6.18 Insulation resistance
6.19 Contact durability\/cycle test
6.20 Environmental requirements <\/td>\n<\/tr>\n\n 82<\/td>\n 6.21 Contacts supplied in reels <\/td>\n<\/tr>\n \n 83<\/td>\n 6.22 Contact solderability
6.23 Contact resistance to soldering heat\/flammability
6.24 Contact crimp tensile strength
6.25 Auxiliary parts
6.26 Marking
6.27 Workmanship
7. Signal module
7.1 Introduction <\/td>\n<\/tr>\n\n 84<\/td>\n 7.2 General specifications <\/td>\n<\/tr>\n \n 90<\/td>\n 7.3 Design and construction requirements <\/td>\n<\/tr>\n \n 91<\/td>\n 7.4 Electrical specifications <\/td>\n<\/tr>\n \n 92<\/td>\n 7.5 Method of examination and test <\/td>\n<\/tr>\n \n 94<\/td>\n 8. Power size 8 and 16 connector module(s)
8.1 Introduction <\/td>\n<\/tr>\n\n 95<\/td>\n 8.2 General specifications <\/td>\n<\/tr>\n \n 96<\/td>\n 8.3 Design and construction requirements <\/td>\n<\/tr>\n \n 100<\/td>\n 8.4 Electrical specifications for 23 A power contact <\/td>\n<\/tr>\n \n 101<\/td>\n 8.5 Electrical specifications for 45 A power contact <\/td>\n<\/tr>\n \n 102<\/td>\n 8.6 Method of examination and test <\/td>\n<\/tr>\n \n 104<\/td>\n 9. Coax size 16 connector module(s)
9.1 Introduction
9.2 General specifications <\/td>\n<\/tr>\n\n 105<\/td>\n 9.3 Design and construction requirements <\/td>\n<\/tr>\n \n 110<\/td>\n 9.4 Coax 5 GHz contact electrical specifications <\/td>\n<\/tr>\n \n 111<\/td>\n 9.5 Coax 3 GHz contact electrical specifications <\/td>\n<\/tr>\n \n 113<\/td>\n 9.6 Method of examination and test <\/td>\n<\/tr>\n \n 114<\/td>\n 10. Mixed power connector module, 28-10 A and 16-20 A positions
10.1 Introduction <\/td>\n<\/tr>\n\n 115<\/td>\n 10.2 General specifications <\/td>\n<\/tr>\n \n 117<\/td>\n 10.3 Design and construction requirements <\/td>\n<\/tr>\n \n 118<\/td>\n 10.4 Electrical specifications <\/td>\n<\/tr>\n \n 119<\/td>\n 11. Universal size 8 connector D-Sub compatible module, 24 position
11.1 Introduction
11.2 General specifications <\/td>\n<\/tr>\n\n 121<\/td>\n 11.3 Design and construction requirements <\/td>\n<\/tr>\n \n 124<\/td>\n 11.4 Coax 40 GHz, size 8, D-Sub compatible, contact <\/td>\n<\/tr>\n \n 125<\/td>\n 11.5 Power 45-A, size 8, D-Sub compatible contact
11.6 Pneumatic, size 8, D-Sub compatible, contact
11.7 Fiber-optic, size 8, D-Sub compatible, contact specifications
12. High-speed signal module
12.1 Introduction
12.2 General specifications <\/td>\n<\/tr>\n\n 128<\/td>\n 12.3 Design and construction requirements <\/td>\n<\/tr>\n \n 130<\/td>\n 12.4 Electrical specifications <\/td>\n<\/tr>\n \n 131<\/td>\n 12.5 Method of examination and test <\/td>\n<\/tr>\n \n 133<\/td>\n Annex A (informative) Receiver fixture interface tutorial <\/td>\n<\/tr>\n \n 151<\/td>\n Annex B (informative) Critical Interface Working Group (CIWG) report <\/td>\n<\/tr>\n \n 152<\/td>\n Annex C (informative) Bibliography <\/td>\n<\/tr>\n \n 155<\/td>\n Annex D (informative) IEEE list of Participants <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" \n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n BSI<\/b><\/a><\/td>\n 2016<\/td>\n 158<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":420909,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[381,2641],"product_tag":[],"class_list":{"0":"post-420904","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-25-040-01","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/420904","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/420909"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=420904"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=420904"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=420904"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}