{"id":400279,"date":"2024-10-20T04:48:40","date_gmt":"2024-10-20T04:48:40","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-802-3bu-2016-2\/"},"modified":"2024-10-26T08:36:37","modified_gmt":"2024-10-26T08:36:37","slug":"ieee-802-3bu-2016-2","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-802-3bu-2016-2\/","title":{"rendered":"IEEE 802.3bu-2016"},"content":{"rendered":"
Amendment Standard – Superseded. Specifications and management parameters for the provision of power via a single twisted pair to connected Data Terminal Equipment (DTE) with IEEE 802.3 single balanced twisted-pair interfaces are added by this amendment to IEEE Std 802.3-2015.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | IEEE Std 802.3bu-2016 Front Cover <\/td>\n<\/tr>\n | ||||||
2<\/td>\n | Title page <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | Important Notices and Disclaimers Concerning IEEE Standards Documents <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | Participants <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | Contents <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 1. Introduction 1.4 Definitions <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 1.5 Abbreviations <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 30. Management 30.2 Managed objects 30.2.2 Overview of managed objects 30.2.2.1 Text description of managed objects 30.2.3 Containment <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 30.2.5 Capabilities <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 30.15 Layer management for Power over Data Lines (PoDL) of Single Balanced Twisted-Pair Ethernet 30.15.1 PoDL PSE managed object class <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 30.15.1.1 PoDL PSE attributes 30.15.1.1.1 aPoDLPSEID 30.15.1.1.2 aPoDLPSEAdminState 30.15.1.1.3 aPoDLPSEPowerDetectionStatus <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 30.15.1.1.4 aPoDLPSEType 30.15.1.1.5 aPoDLPSEDetectedPDType 30.15.1.1.6 aPoDLPSEDetectedPDPowerClass <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 30.15.1.1.7 aPoDLPSEInvalidSignatureCounter 30.15.1.1.8 aPoDLPSEInvalidClassCounter 30.15.1.1.9 aPoDLPSEPowerDeniedCounter <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 30.15.1.1.10 aPoDLPSEOverLoadCounter 30.15.1.1.11 aPoDLPSEMaintainFullVoltageSignatureAbsentCounter 30.15.1.1.12 aPoDLPSEActualPower 30.15.1.1.13 aPoDLPSEPowerAccuracy <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | 30.15.1.1.14 aPoDLPSECumulativeEnergy 30.15.1.2 PoDL PSE actions 30.15.1.2.1 acPoDLPSEAdminControl <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | 45. Management Data Input\/Output (MDIO) Interface 45.2 MDIO Interface Registers <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | 45.2.7b Power Unit Registers 45.2.7b.1 PoDL PSE Control register (Register 13.0) 45.2.7b.1.1 Enable power classification (13.0.1) 45.2.7b.1.2 PSE Enable (13.0.0) 45.2.7b.2 PoDL PSE Status 1 register (Register 13.1) <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | 45.2.7b.2.1 Power Denied (13.1.15) <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | 45.2.7b.2.2 Valid Signature (13.1.14) 45.2.7b.2.3 Invalid Signature (13.1.13) 45.2.7b.2.4 Class Timeout (13.1.12) 45.2.7b.2.5 Overload (13.1.11) 45.2.7b.2.6 MFVS Absent (13.1.10) 45.2.7b.2.7 PSE Type (13.1.9:7) 45.2.7b.2.8 PD Class (13.1.6:3) 45.2.7b.2.9 PSE Status (13.1.2:0) <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | 45.2.7b.3 PoDL PSE Status 2 register (Register 13.2) 45.2.7b.3.1 Invalid Class (13.2.15) 45.2.7b.3.2 PD Type (13.2.2:0) 45.5 Protocol implementation conformance statement (PICS) proforma for Clause 45, MDIO interface 45.5.3 Major capabilities\/options <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | 45.5.3.13b Power over Data Lines (PoDL) of Single Balanced Twisted-Pair Ethernet management functions <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | 96. Physical Coding Sublayer (PCS), Physical Medium Attachment (PMA) sublayer and baseband medium, type 100BASE-T1 96.5.4.1 Transmitter output droop 96.8.2.1 MDI return loss <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | 104. Power over Data Lines (PoDL) of Single Balanced Twisted-Pair Ethernet 104.1 Overview 104.1.1 Compatibility considerations 104.1.2 Relationship of PoDL to the IEEE 802.3 architecture <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | 104.1.3 PoDL system types <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | 104.2 Link segment <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | 104.3 Class power requirements 104.4 Power Sourcing Equipment (PSE) 104.4.1 PSE types <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | 104.4.2 PSE classes 104.4.3 PSE state diagram 104.4.3.1 Overview 104.4.3.2 Conventions 104.4.3.3 Variables <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | 104.4.3.4 Timers <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | 104.4.3.5 Functions <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | 104.4.3.6 State diagram <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | 104.4.4 PSE detection of a PD 104.4.4.1 Detection probe requirements 104.4.4.2 Detection criteria 104.4.4.3 Rejection criteria <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | 104.4.5 PSE classification of a PD 104.4.6 PSE output requirements <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | 104.4.6.1 Output voltage 104.4.6.2 Output current 104.4.6.2.1 Output current\u2014at overload condition <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | 104.4.6.2.2 Wakeup current signature detection 104.4.6.2.3 Output current requirement during idle 104.4.6.3 Power feeding ripple and transients <\/td>\n<\/tr>\n | ||||||
50<\/td>\n | 104.4.6.4 Inrush time 104.4.6.5 Turn off time <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | 104.4.6.6 Disable time 104.4.6.7 Continuous output power in POWER_ON state 104.4.7 PSE power removal 104.4.7.1 PSE MFVS requirements 104.5 Powered Device (PD) 104.5.1 PD types 104.5.2 PD classes <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | 104.5.3 PD state diagram 104.5.3.1 Overview 104.5.3.2 Conventions 104.5.3.3 Variables <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | 104.5.3.4 Timers 104.5.3.5 Functions <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | 104.5.3.6 State diagram 104.5.4 PD signature <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | 104.5.5 PD classification and mutual identification between the PSE and PD 104.5.6 PD power <\/td>\n<\/tr>\n | ||||||
57<\/td>\n | 104.5.6.1 PD discharge 104.5.6.2 PD input voltage 104.5.6.3 Input current <\/td>\n<\/tr>\n | ||||||
58<\/td>\n | 104.5.6.4 PD ripple and transients 104.5.6.5 Input average power <\/td>\n<\/tr>\n | ||||||
59<\/td>\n | 104.5.6.6 PD stability 104.5.7 PD Maintain full voltage 104.6 Additional electrical specifications 104.6.1 Isolation 104.6.2 Fault tolerance <\/td>\n<\/tr>\n | ||||||
60<\/td>\n | 104.7 Serial communication classification protocol (SCCP) 104.7.1 SCCP signaling 104.7.1.1 Initialization procedure\u2014reset and presence pulses 104.7.1.2 Write time slots <\/td>\n<\/tr>\n | ||||||
61<\/td>\n | 104.7.1.3 Read time slots <\/td>\n<\/tr>\n | ||||||
63<\/td>\n | 104.7.2 Serial communication classification protocols 104.7.2.1 SCCP transaction sequence 104.7.2.2 Initialization 104.7.2.3 Address commands 104.7.2.3.1 Broadcast address [0xCC] 104.7.2.4 Read_Scratchpad function command [0xAA] 104.7.2.5 CRC8 field <\/td>\n<\/tr>\n | ||||||
65<\/td>\n | 104.8 Environmental 104.8.1 General safety 104.8.2 Network safety 104.8.3 Installation and maintenance guidelines <\/td>\n<\/tr>\n | ||||||
66<\/td>\n | 104.8.4 Patch panel considerations 104.8.5 Telephony voltages 104.8.6 Electromagnetic emissions 104.8.7 Temperature and humidity <\/td>\n<\/tr>\n | ||||||
67<\/td>\n | 104.9 Protocol implementation conformance statement (PICS) proforma for Clause 104, Power over Data Lines (PoDL) of Single Balanced Twisted-Pair Ethernet 104.9.1 Introduction 104.9.2 Identification 104.9.2.1 Implementation identification 104.9.2.2 Protocol summary <\/td>\n<\/tr>\n | ||||||
68<\/td>\n | 104.9.3 Major capabilities\/options 104.9.4 PICS proforma tables for Clause 104, Power over Data Lines (PoDL) of Single Balanced Twisted-Pair Ethernet 104.9.4.1 Link Segment <\/td>\n<\/tr>\n | ||||||
69<\/td>\n | 104.9.4.2 Power Sourcing Equipment (PSE) <\/td>\n<\/tr>\n | ||||||
72<\/td>\n | 104.9.4.3 Powered Device (PD) <\/td>\n<\/tr>\n | ||||||
74<\/td>\n | 104.9.4.4 Common Electrical 104.9.4.5 PSE Electrical 104.9.4.6 PD Electrical 104.9.4.7 SCCP <\/td>\n<\/tr>\n | ||||||
76<\/td>\n | 104.9.4.8 Environmental <\/td>\n<\/tr>\n | ||||||
77<\/td>\n | Back cover <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" IEEE Standard for Ethernet–Amendment 8: Physical Layer and Management Parameters for Power over Data Lines (PoDL) of Single Balanced Twisted-Pair Ethernet<\/b><\/p>\n |