{"id":384989,"date":"2024-10-20T03:28:34","date_gmt":"2024-10-20T03:28:34","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/asme-csd-1-2021\/"},"modified":"2024-10-26T06:18:09","modified_gmt":"2024-10-26T06:18:09","slug":"asme-csd-1-2021","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/asme\/asme-csd-1-2021\/","title":{"rendered":"ASME CSD 1 2021"},"content":{"rendered":"
The rules of this Standard cover requirements for the assembly, installation, maintenance, and operation of controls and safety devices on automatically operated boilers directly fired with gas, oil, gas-oil, or electricity, having fuel input ratings under 12,500,000 Btu\/hr.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
4<\/td>\n | CONTENTS <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | FOREWORD <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | ASME CSDAFB COMMITTEE ROSTER <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | CORRESPONDENCE WITH THE CSDAFB COMMITTEE <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | ASME CSD-1\u20132021 SUMMARY OF CHANGES <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | Part CG General CG-100 GENERAL REQUIREMENTS CG-110 Scope CG-120 Service Limitations CG-130 Exclusions CG-140 Acceptance of Other Listings CG-150 Jurisdictional Adoption of ASME CSD-1 CG-160 Metric (SI) Units <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | CG-200 GENERAL PROVISIONS CG-210 General CG-220 Installation CG-230 Observation Ports CG-240 Guarding CG-250 Annunciator Systems CG-260 Combustion Air CG-300 MATERIAL REQUIREMENTS CG-310 Components CG-400 TESTING AND MAINTENANCE CG-410 Cleaning CG-420 Testing CG-430 Maintenance <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | CG-440 Operational Testing CG-500 CERTIFICATION AND REPORTING CG-510 Certification and Reporting CG-600 OPERATION CG-610 Lockout CG-700 DEFINITIONS <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | Figures Figure CG-700-1 Sediment Trap <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | Part CM Testing and Maintenance CM-100 PERIODIC TESTING AND MAINTENANCE CM-110 General CM-120 Familiarity With Equipment and Procedures CM-130 Periodic Maintenance and Testing <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | Part CE Electrical CE-100 ELECTRICAL REQUIREMENTS CE-110 General CE-120 Overcurrent Protection <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | CE-130 Motors CE-140 Ignition System CE-150 Wiring CE-160 Bonding and Grounding CE-170 Annunciation, Status, and Control Wiring to Primary Safety Control Systems <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | Part CW Steam and Waterside Control CW-100 AUTOMATIC LOW-WATER FUEL CUTOFF AND\/OR COMBINED WATER FEEDING DEVICE CW-110 General Requirements for Water Level Controls for All Boilers CW-120 Requirements for Water Level Controls for Low-Pressure Steam Boilers <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | CW-130 Requirements for Water Level Controls for Hot Water Heating Boilers CW-140 Requirements for Water Level Controls for High-Pressure Steam Boilers <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | CW-150 Requirements for Operating and Safety Controls for Electrically Heated Boilers CW-200 AUTOMATIC FUEL CUTOFF FOR FORCED CIRCULATION BOILERS CW-210 Requirements for Flow or Temperature Sensing Devices for Forced Circulation Boilers CW-300 PRESSURE CONTROLS CW-310 Requirements for Pressure Controls for Steam Boilers <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | CW-400 TEMPERATURE CONTROLS CW-410 Requirements for Temperature Controls for Hot Water Boilers <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | CW-500 SAFETY AND SAFETY RELIEF VALVES CW-510 Requirements for Steam and Hot Water Heating Boilers CW-520 Requirements of Hot Water Supply Boilers CW-600 MODULAR BOILERS CW-610 Water Level Controls for Modular Steam Heating Boilers CW-620 Pressure Controls for Modular Steam Heating Boilers CW-630 Water Level Controls for Modular Hot Water Boilers CW-640 Temperature Controls for Modular Hot Water Heating Boilers CW-700 VACUUM BOILERS CW-710 Requirements for Vacuum Boilers <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | Part CF Combustion Side Control CF-100 GAS-FIRED BOILER UNITS, EQUIPMENT CF-110 Burner Assemblies and Boiler Units CF-120 Fuel Train CF-130 Filters or Strainers CF-140 Sediment Traps and Drips CF-150 Manually Operated Gas Shutoff Valves <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | Tables Table CF-110-1 400,000 Btu\/hr (117 kW) and Smaller (Gas \u2014 Natural Draft) <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | Table CF-110-2 400,000 Btu\/hr (117 kW) and Smaller (Power Gas Burners, Mechanical Draft Atmospheric Gas Burners, Pulse Combustion Systems), 3 gph (11.4 L\/h) [Approximately 400,000 Btu\/hr (117 kW)] and Smaller (Oil) <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | CF-160 Gas-Pressure Regulators <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | Table CF-162-1 Safety Controls for Automatically Fired Units: Power Gas Burners, Mechanical Draft Atmospheric Gas Burners, and Pulse Combustion Systems <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | Table CF-162-2 Safety Controls for Automatically Fired Units: Atmospheric Gas Burners \u2014 Natural Draft <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | CF-170 Control Valves CF-180 Safety Shutoff Valves <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | CF-190 Vent Lines, Bleed Lines, Gas-Pressure Relief Lines, Vent Valve Lines, and Feedback Lines for Fuel Train Components <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | CF-200 GAS-FIRED BOILER UNITS, PURGING CF-210 Preignition Purging <\/td>\n<\/tr>\n | ||||||
40<\/td>\n | CF-220 Control CF-300 GAS-FIRED BOILER UNITS, SAFETY CONTROLS CF-310 Primary Safety Control CF-320 Automatic Ignition Devices CF-330 Action on Flame Failure <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | CF-400 OIL-FIRED BOILER UNITS, EQUIPMENT CF-410 Burner Assemblies CF-420 Fuel Train CF-430 Filters or Strainers CF-440 Relief Valves CF-450 Pressure and Temperature Switches CF-460 Safety Shutoff Valves <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | CF-470 Oil-Fired Boiler Units, Purging CF-480 Combustion Air Proving CF-500 OIL-FIRED BOILER UNITS, SAFETY CONTROLS CF-510 Primary Safety Control CF-520 Automatic Ignition Devices CF-530 Action on Flame Failure CF-540 Automatic Stack Dampers <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | Table CF-460-1 Safety Controls for Automatically Fired Units: Oil-Fired Burners <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | CF-600 LOW FIRE START, GAS- OR OIL-FIRED BOILER UNITS CF-610 Low Fire Start CF-700 COMBINATION GAS- AND OIL-FIRED UNITS CF-710 Burner Assemblies CF-800 ELECTRICALLY HEATED BOILERS CF-810 General CF-900 COMBUSTION SIDE CONTROLS FOR MODULAR BOILERS CF-910 Gas Modular Boilers CF-920 Oil Modular Boilers CF-930 Electric Modular Boilers CF-1000 Requirements for the Use of Variable Frequency Drives (VFD) CF-1010 VFD Used on Combustion Air Fan <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | NONMANDATORY APPENDICES NONMANDATORY APPENDIX A COMPARISON OF THIS STANDARD AND ANSI Z21.13\/CSA 4.9 <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | Table B-1 Figure Index NONMANDATORY APPENDIX B TYPICAL FUEL TRAINS <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | Figure B-1 Typical Gas Fuel Train With Pilot Ignition System and Atmospheric Burners [Greater Than 400,000 Btu\/hr (117 kW) and Less Than or Equal to 2,500,000 Btu\/hr (733 kW)] <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | Figure B-2 Typical Gas Fuel Train With Pilot Ignition System [Greater Than 400,000 Btu\/hr (117 kW) and Less Than or Equal to 2,500,000 Btu\/hr (733 kW)] <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | Figure B-3 Typical Gas Fuel Train With Direct Ignition System [Greater Than 400,000 Btu\/hr (117 kW) and Less Than or Equal to 2,500,000 Btu\/hr (733 kW)] <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | Figure B-4 Typical Gas Fuel Train With Pilot Ignition System [Greater Than 2,500,000 Btu\/hr (733 kW) and Less Than or Equal to 5,000,000 Btu\/hr (1 465 kW)] <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | Figure B-5 Typical Gas Fuel Train With Pilot Ignition System [Greater Than 5,000,000 Btu\/hr (1 465 kW) and Less Than 12,500,000 Btu\/hr (3 663 kW)] <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | Figure B-6 Typical Gas Fuel Train With Pilot Ignition System and Negative (Zero Governor) Main Manifold Gas Pressure [Greater Than 400,000 Btu\/hr (117 kW) and Less Than 12,500,000 Btu\/hr (3 663 kW)] <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | Figure B-7 Typical Gas Fuel Train With Direct Ignition System and Negative (Zero Governor) Main Manifold Gas Pressure [Greater Than 400,000 Btu\/hr (117 kW) and Less Than 12,500,000 Btu\/hr (3 663 kW)] Figure B-8 Typical Oil Fuel Train <\/td>\n<\/tr>\n | ||||||
57<\/td>\n | Figure B-9 Example for Sizing of Manifolded Lines Figure B-10 Typical Gas Fuel Train Safety Shutoff Valve Arrangements for Multiple-Burner Boiler Units Complying With CF-180(b) <\/td>\n<\/tr>\n | ||||||
58<\/td>\n | NONMANDATORY APPENDIX C MANUFACTURER\u2019S\/INSTALLING CONTRACTOR\u2019S REPORT FOR ASME CSD-1 <\/td>\n<\/tr>\n | ||||||
61<\/td>\n | NONMANDATORY APPENDIX D RECOMMENDED PREVENTIVE MAINTENANCE SCHEDULE D-1 INTRODUCTION D-2 DAILY D-3 WEEKLY D-4 MONTHLY D-5 SEMIANNUALLY D-6 ANNUALLY D-7 AS REQUIRED <\/td>\n<\/tr>\n | ||||||
63<\/td>\n | Table D-1-1 Periodic Testing Recommended Checklist <\/td>\n<\/tr>\n | ||||||
66<\/td>\n | NONMANDATORY APPENDIX E REFERENCES <\/td>\n<\/tr>\n | ||||||
67<\/td>\n | NONMANDATORY APPENDIX F GUIDANCE FOR THE USE OF U.S. CUSTOMARY AND SI UNITS IN ASME CSD-1 F-1 USE OF UNITS IN EQUATIONS F-2 GUIDELINES USED TO DEVELOP SI EQUIVALENTS <\/td>\n<\/tr>\n | ||||||
69<\/td>\n | F-3 SOFT CONVERSION FACTORS <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" ASME CSD-1 – 2021 Controls and Safety Devices for Automatically Fired Boilers<\/b><\/p>\n |