{"id":290821,"date":"2024-10-19T19:44:23","date_gmt":"2024-10-19T19:44:23","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-iso-115052012\/"},"modified":"2024-10-25T16:45:05","modified_gmt":"2024-10-25T16:45:05","slug":"bs-iso-115052012","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-iso-115052012\/","title":{"rendered":"BS ISO 11505:2012"},"content":{"rendered":"
This International Standard describes a glow discharge optical emission spectrometric (GD-OES) method for the determination of the thickness, mass per unit area and chemical composition of surface layer films.<\/p>\n
It is limited to a description of general procedures of quantification of GD-OES and is not applicable directly for the quantification of individual materials having various thicknesses and elements to be determined.<\/p>\n
\nNOTE Any individual standard for a test material will have to specify a scope of a thickness of the surface layer as well as analyte elements, and include results of interlaboratory tests for validation of the methods.<\/p>\n<\/blockquote>\n
PDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 6<\/td>\n Foreword <\/td>\n<\/tr>\n \n 7<\/td>\n Section sec_1
Section sec_2
Section sec_3
Section sec_4
Section sec_4.1
Section sec_4.1.1
1\tScope
2\tNormative references
3\tPrinciple
4\tApparatus
4.1\tGlow discharge optical emission spectrometer <\/td>\n<\/tr>\n\n 8<\/td>\n Section sec_4.1.2
Section sec_4.1.3
Section sec_4.1.3.1
Section sec_4.1.3.2 <\/td>\n<\/tr>\n\n 9<\/td>\n Section sec_4.1.3.3
Section sec_5
Section sec_5.1
5\tAdjusting the glow discharge spectrometer system settings
5.1\tGeneral <\/td>\n<\/tr>\n\n 10<\/td>\n Section sec_5.2
Section sec_5.2.1
Section sec_5.2.1.1
Section sec_5.2.1.2
Section sec_5.2.1.3
5.2\tSetting the discharge parameters of a DC source <\/td>\n<\/tr>\n\n 11<\/td>\n Section sec_5.2.1.4
Section sec_5.2.2
Section sec_5.2.2.1 <\/td>\n<\/tr>\n\n 12<\/td>\n Section sec_5.3
Section sec_5.3.1
Section sec_5.3.2
Section sec_5.3.3
5.3\tSetting the discharge parameters of an RF source <\/td>\n<\/tr>\n\n 13<\/td>\n Section sec_5.4
Section sec_5.4.1
Section sec_5.4.2
Section sec_5.4.3
Section sec_5.4.3.1
Section sec_5.4.3.2
5.4\tMinimum performance requirements <\/td>\n<\/tr>\n\n 14<\/td>\n Section sec_5.4.3.3 <\/td>\n<\/tr>\n \n 15<\/td>\n Section sec_6
Section sec_7
Section sec_7.1
Section sec_7.2
Section sec_7.2.1
6\tSampling
7\tCalibration
7.1\tGeneral
7.2\tCalibration specimens <\/td>\n<\/tr>\n\n 16<\/td>\n Section sec_7.2.2
Section sec_7.2.3
Section sec_7.2.4
Section sec_7.2.5
Section sec_7.2.6
Section sec_7.2.7 <\/td>\n<\/tr>\n\n 17<\/td>\n Section sec_7.2.8
Section sec_7.3
Section sec_7.4
7.3\tValidation specimens
7.4\tDetermination of the sputtering rate of calibration and validation specimens <\/td>\n<\/tr>\n\n 18<\/td>\n Section sec_7.5
Section sec_7.6
Section sec_7.7
Section sec_7.7.1
7.5\tEmission intensity measurements of calibration specimens
7.6\tCalculation of calibration equations
7.7\tValidation of the calibration <\/td>\n<\/tr>\n\n 19<\/td>\n Section sec_7.7.2
Section sec_7.7.3
Section sec_7.8
7.8\tVerification and drift correction <\/td>\n<\/tr>\n\n 20<\/td>\n Section sec_8
Section sec_8.1
Section sec_8.2
Section sec_8.3
8\tAnalysis of test specimens
8.1\tAdjusting discharge parameters
8.2\tSetting of measuring time and data acquisition rate
8.3\tQuantifying depth profiles of test specimens <\/td>\n<\/tr>\n\n 21<\/td>\n Section sec_9
Section sec_9.1
Table tab_c
Figure fig_1
Section sec_9.2
Section sec_9.2.1
9\tExpression of results
9.1\tExpression of quantitative depth profile
9.2\tDetermination of total coating mass per unit area <\/td>\n<\/tr>\n\n 22<\/td>\n Section sec_9.2.2
Section sec_9.3
Section sec_10
Section sec_11
9.3\tDetermination of average mass fractions
10\tPrecision
11\tTest report <\/td>\n<\/tr>\n\n 23<\/td>\n Annex sec_A
Annex sec_A.1
Annex sec_A.2
Annex sec_A.2.1
Annex\u00a0A
\n(normative)<\/p>\nCalculation of calibration constants and quantitative evaluation of depth profiles <\/td>\n<\/tr>\n
\n 25<\/td>\n Annex sec_A.2.2
Annex sec_A.2.3 <\/td>\n<\/tr>\n\n 26<\/td>\n Annex sec_A.3 <\/td>\n<\/tr>\n \n 27<\/td>\n Annex sec_A.4 <\/td>\n<\/tr>\n \n 28<\/td>\n Annex sec_A.5
Annex sec_A.5.1 <\/td>\n<\/tr>\n\n 29<\/td>\n Annex sec_A.5.2
Annex sec_A.5.3 <\/td>\n<\/tr>\n\n 30<\/td>\n Annex sec_A.5.4
Annex sec_A.6
Annex sec_A.6.1
Annex sec_A.6.2 <\/td>\n<\/tr>\n\n 31<\/td>\n Annex sec_A.6.3
Annex sec_A.7
Annex sec_A.7.1 <\/td>\n<\/tr>\n\n 32<\/td>\n Annex sec_A.7.2
Annex sec_A.7.3 <\/td>\n<\/tr>\n\n 33<\/td>\n Annex sec_A.8
Annex sec_A.8.1 <\/td>\n<\/tr>\n\n 34<\/td>\n Annex sec_A.8.2
Annex sec_A.8.3 <\/td>\n<\/tr>\n\n 35<\/td>\n Annex sec_A.9
Annex sec_A.9.1
Annex sec_A.9.2 <\/td>\n<\/tr>\n\n 36<\/td>\n Annex sec_A.9.3 <\/td>\n<\/tr>\n \n 37<\/td>\n Annex sec_B
Annex\u00a0B
\n(informative)<\/p>\nSuggested spectral lines for determination of given elements <\/td>\n<\/tr>\n
\n 39<\/td>\n Reference ref_1
Reference ref_2
Reference ref_3
Reference ref_4
Reference ref_5
Reference ref_6
Reference ref_7
Reference ref_8
Reference ref_9
Reference ref_10
Reference ref_11
Reference ref_12
Reference ref_13
Reference ref_14
Reference ref_15
Reference ref_16
Reference ref_17
Reference ref_18
Reference ref_19
Reference ref_20
Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"Surface chemical analysis. General procedures for quantitative compositional depth profiling by glow discharge optical emission spectrometry<\/b><\/p>\n
\n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n BSI<\/b><\/a><\/td>\n 2013<\/td>\n 42<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":290824,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[1000,2641],"product_tag":[],"class_list":{"0":"post-290821","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-71-040-40","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/290821","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/290824"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=290821"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=290821"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=290821"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}