{"id":271293,"date":"2024-10-19T18:11:17","date_gmt":"2024-10-19T18:11:17","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-13272-12019\/"},"modified":"2024-10-25T14:24:04","modified_gmt":"2024-10-25T14:24:04","slug":"bs-en-13272-12019","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-13272-12019\/","title":{"rendered":"BS EN 13272-1:2019"},"content":{"rendered":"
This document contains performance requirements and recommendations for electrical lighting systems in the interiors of public transport heavy rail units, under all operating and emergency conditions.<\/p>\n
This document applies only to new units.<\/p>\n
The application of this document for retro-fitting of existing units can be subject to agreement between Contractors.<\/p>\n
This document also defines the requirements for testing and conformity assessment.<\/p>\n
This document does not address lighting installed in instruments or controls.<\/p>\n
This document does not address the requirements of lighting of boarding aids, e.g. moving entrance stairs or lifts.<\/p>\n
This document does not address lighting installed for indication or effect purposes, including flashing lights and decorative lighting.<\/p>\n
The requirements for interior lighting for urban rail units can be found in EN 13272\u20132<\/span><\/span> .<\/p>\n<\/div>\n The requirements for cab instrument lighting for heavy rail units can be found in EN 16186\u20132<\/span><\/span> .<\/p>\n<\/div>\n Railway applications. Electrical lighting for rolling stock in public transport systems – Heavy rail<\/b><\/p>\nPDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 2<\/td>\n undefined <\/td>\n<\/tr>\n \n 7<\/td>\n 1 Scope
2 Normative references
3 Terms and definitions
3.1 General <\/td>\n<\/tr>\n\n 11<\/td>\n 3.2 Types of lighting <\/td>\n<\/tr>\n \n 12<\/td>\n 4 Requirements for lighting in passenger areas
4.1 General lighting
4.1.1 General
4.1.2 Illuminance and uniformity <\/td>\n<\/tr>\n\n 14<\/td>\n 4.1.3 Glare limitation
4.1.4 Correlated colour temperature <\/td>\n<\/tr>\n\n 15<\/td>\n 4.1.5 Colour rendering
4.1.6 Illuminance in vehicles for night service
4.1.7 Reduced lighting
4.1.8 Lighting control functions
4.1.9 Photobiological safety
4.2 Stand-by lighting
4.3 Emergency lighting
4.3.1 General <\/td>\n<\/tr>\n\n 16<\/td>\n 4.3.2 Power supply
4.3.3 Illuminance
4.3.4 Uniformity of illuminance
4.3.5 Glare limitation
4.3.6 Starting performance <\/td>\n<\/tr>\n\n 17<\/td>\n 4.3.7 Operating time
4.3.8 Location of emergency lighting
4.3.9 Correlated colour temperature
4.3.10 Colour rendering
4.3.11 Maintenance <\/td>\n<\/tr>\n\n 18<\/td>\n 5 Requirements for lighting in service areas
5.1 General lighting
5.1.1 General
5.1.2 Illuminance
5.1.3 Glare limitation
5.1.4 Correlated colour temperature and colour rendering <\/td>\n<\/tr>\n\n 19<\/td>\n 5.1.5 Controls for cab lighting
5.1.6 Photobiological safety
5.2 Stand-by lighting
5.3 Emergency lighting
5.3.1 General
5.3.2 Power supply
5.3.3 Illuminance
5.3.4 Uniformity of illuminance <\/td>\n<\/tr>\n\n 20<\/td>\n 5.3.5 Glare limitation
5.3.6 Starting performance
5.3.7 Operating time
5.3.8 Location of emergency lighting
5.3.9 Maintenance
6 Measuring equipment, conditions and measuring points
6.1 General
6.2 Measuring equipment <\/td>\n<\/tr>\n\n 21<\/td>\n 6.3 Equipment calibration
6.4 Conditions for illuminance measurement
6.5 Locations for illuminance measurement <\/td>\n<\/tr>\n\n 22<\/td>\n 6.6 Measurement of illuminance and glare
6.7 Measurement of correlated colour temperature and colour rendering
6.8 Determination of photobiological safety parameters
7 Further requirements on the design of lighting systems
7.1 General <\/td>\n<\/tr>\n\n 23<\/td>\n 7.2 Arrangement of luminaires at vehicle access steps
7.3 Maintenance <\/td>\n<\/tr>\n\n 24<\/td>\n Annex A (normative)Contractual statements – Information and requirements to be agreed and documented
A.1 General
A.2 Items for agreement <\/td>\n<\/tr>\n\n 25<\/td>\n Annex B (normative)Definition of the door and access step width requirement for illuminance measurements <\/td>\n<\/tr>\n \n 26<\/td>\n Annex C (informative)Test pulse characteristics <\/td>\n<\/tr>\n \n 27<\/td>\n Annex ZA (informative)Relationship between this European Standard and the Essential Requirements of EU Directive 2016\/797\/EC aimed to be covered <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" \n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n BSI<\/b><\/a><\/td>\n 2019<\/td>\n 32<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":271296,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2641],"product_tag":[],"class_list":{"0":"post-271293","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-bsi","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/271293","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/271296"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=271293"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=271293"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=271293"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}