{"id":255457,"date":"2024-10-19T16:53:15","date_gmt":"2024-10-19T16:53:15","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bsi-pd-iec-tr-613282017\/"},"modified":"2024-10-25T12:20:54","modified_gmt":"2024-10-25T12:20:54","slug":"bsi-pd-iec-tr-613282017","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bsi-pd-iec-tr-613282017\/","title":{"rendered":"BSI PD IEC\/TR 61328:2017"},"content":{"rendered":"

This document, which is a Technical Report, provides recommendations for the selection and testing where necessary of conductor stringing<\/i> equipment and accessory items used for the installation of bare and insulated overhead distribution conductors<\/i>, bare overhead transmission conductors<\/i> and overhead earth wire<\/i>s.<\/p>\n

Procedures are recommended for proper earthing in order to protect equipment, components and personnel from currents which can result from accidental contact with nearby energized conductors<\/i> or from the induced or fault currents<\/i> which can result in some circumstances.<\/p>\n

The items of equipment under consideration in this document are used for transmission and distribution systems.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
2<\/td>\nNational foreword <\/td>\n<\/tr>\n
4<\/td>\nCONTENTS <\/td>\n<\/tr>\n
6<\/td>\nFOREWORD <\/td>\n<\/tr>\n
8<\/td>\nINTRODUCTION <\/td>\n<\/tr>\n
9<\/td>\n1 Scope
2 Normative references
3 Terms and definitions <\/td>\n<\/tr>\n
19<\/td>\n4 Understanding the hazard \u2013 Basic theory
4.1 General
4.2 Electric field induction from nearby circuits
4.2.1 Overview <\/td>\n<\/tr>\n
20<\/td>\n4.2.2 Induced voltage
Figures
Figure 1 \u2013 Electric field induction from nearby circuits \u2013 Induced voltage <\/td>\n<\/tr>\n
21<\/td>\n4.2.3 Induced current
Figure 2 \u2013 Electric field induction from nearby circuits \u2013 Induced current <\/td>\n<\/tr>\n
22<\/td>\n4.2.4 Electrostatic charging
4.3 Magnetic field induction from nearby circuits
4.3.1 Induced current <\/td>\n<\/tr>\n
23<\/td>\n4.3.2 Induced voltage
Figure 3 \u2013 Magnetic field induction from nearby circuits \u2013 Induced current <\/td>\n<\/tr>\n
24<\/td>\n4.4 Re-energization
4.5 Mechanical risk
Figure 4 \u2013 Magnetic field induction from nearby circuits \u2013 Induced voltage <\/td>\n<\/tr>\n
25<\/td>\n5 Conductor stringing methods and equipment
5.1 General
5.2 Slack stringing method <\/td>\n<\/tr>\n
27<\/td>\n5.3 Tension stringing method
Figure 5 \u2013 Slack stringing method <\/td>\n<\/tr>\n
35<\/td>\nFigure 6 \u2013 Tension stringing method <\/td>\n<\/tr>\n
36<\/td>\n5.4 Stringing equipment
5.4.1 General
5.4.2 Tensioners <\/td>\n<\/tr>\n
39<\/td>\n5.4.3 Pullers
Figure 7 \u2013 Bullwheel tensioners <\/td>\n<\/tr>\n
43<\/td>\n5.4.4 Reel winders
Figure 8 \u2013 Bullwheel pullers <\/td>\n<\/tr>\n
44<\/td>\n5.4.5 Reel stands <\/td>\n<\/tr>\n
45<\/td>\n5.4.6 Pilot rope puller
5.4.7 Pilot rope, pulling rope <\/td>\n<\/tr>\n
46<\/td>\n5.4.8 Woven wire grip
5.4.9 Stringing blocks <\/td>\n<\/tr>\n
49<\/td>\n5.4.10 Stringing rollers
Figure 9 \u2013 Stringing blocks <\/td>\n<\/tr>\n
50<\/td>\n5.4.11 Stringing block earth
Figure 10 \u2013 Stringing rollers <\/td>\n<\/tr>\n
51<\/td>\n5.4.12 Running earth
5.4.13 Hold-down block
5.4.14 Conductor car <\/td>\n<\/tr>\n
52<\/td>\nFigure 11 \u2013 Conductor cars <\/td>\n<\/tr>\n
55<\/td>\n5.5 Communications
6 Special earthing requirements
6.1 General <\/td>\n<\/tr>\n
56<\/td>\n6.2 Work site earthing systems
6.2.1 Overview <\/td>\n<\/tr>\n
57<\/td>\n6.2.2 Use of earth rods <\/td>\n<\/tr>\n
58<\/td>\n6.2.3 Equipment earths
6.2.4 Earths for conductor, earth wire, metallic and synthetic rope
6.2.5 Earths for earth mat, conductors or earth wires
6.2.6 Earths for mid-span joining of conductors or earth wires <\/td>\n<\/tr>\n
59<\/td>\n6.2.7 Earths for clipping in the conductors or earth wires
6.2.8 Earths for installation of jumper loops for the conductor
6.2.9 Stringing block earths
6.2.10 Earth mat <\/td>\n<\/tr>\n
64<\/td>\n6.3 General procedures and use of earthing systems
6.3.1 Overview
6.3.2 General procedures
Figure 12 \u2013 Earthing systems <\/td>\n<\/tr>\n
65<\/td>\n6.3.3 Installation of the pilot or pulling rope <\/td>\n<\/tr>\n
66<\/td>\n6.3.4 Stringing of conductors <\/td>\n<\/tr>\n
67<\/td>\n6.3.5 Splicing of conductors <\/td>\n<\/tr>\n
68<\/td>\n6.3.6 Sagging of conductors <\/td>\n<\/tr>\n
69<\/td>\n6.3.7 Clipping-in conductors
6.3.8 Dead-ending and installation of jumper loops <\/td>\n<\/tr>\n
70<\/td>\n6.3.9 Spacing
6.3.10 Special work on conductors <\/td>\n<\/tr>\n
71<\/td>\n6.3.11 Fuelling
7 Testing of earthing devices
7.1 General <\/td>\n<\/tr>\n
72<\/td>\n7.2 Number of type tests
7.3 Type test set-up
7.4 Type test acceptance criterion <\/td>\n<\/tr>\n
73<\/td>\nFigure 13 \u2013 Typical test set-up for stringing block earth <\/td>\n<\/tr>\n
74<\/td>\nFigure 14 \u2013 Typical test set-up for running earth <\/td>\n<\/tr>\n
75<\/td>\nBibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Live working. Guidelines for the installation of transmission and distribution line conductors and earth wires. Stringing equipment and accessory items<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2017<\/td>\n80<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":255460,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2641],"product_tag":[],"class_list":{"0":"post-255457","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-bsi","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/255457","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/255460"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=255457"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=255457"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=255457"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}