{"id":244716,"date":"2024-10-19T16:05:00","date_gmt":"2024-10-19T16:05:00","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bsi-pd-iec-ts-62257-12-12015\/"},"modified":"2024-10-25T11:04:27","modified_gmt":"2024-10-25T11:04:27","slug":"bsi-pd-iec-ts-62257-12-12015","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bsi-pd-iec-ts-62257-12-12015\/","title":{"rendered":"BSI PD IEC\/TS 62257-12-1:2015"},"content":{"rendered":"
This part of IEC 62257 establishes the framework for creating a product specification \u2013 the basis for evaluating quality for a particular context. Product specifications include minimum requirements for quality standards, warranty requirements, and\/or performance criteria. Products are compared to specifications based on test results and other information about the product. The product specification framework is flexible and can accommodate the goals of diverse organizations and institutions.<\/p>\n
This part of IEC 62257 applies to lamps and lighting appliances for off-grid electricity systems that have the following characteristics:<\/p>\n
The power supply is AC or DC:<\/p>\n<\/li>\n
AC nominal voltages up to 250 V;<\/p>\n<\/li>\n
DC nominal voltages up to 48 V.<\/p>\n<\/li>\n
The light source is CFL, linear fluorescent, or LED.<\/p>\n<\/li>\n
Operation of the lamp or lighting appliance does not require any components to be supplied by the testing laboratory other than lampholders, wire, connectors, and a power supply.<\/p>\n<\/li>\n
The lamp or lighting appliance does not include a battery or energy source (for example, a photovoltaic module or electromechanical generator). Luminaires are included in the definition of \u201clighting appliances\u201d if packaged together with a lamp intended to be used with the luminaire. Luminaires without lamps are not included in the scope of this part of IEC 62257.<\/p>\n<\/li>\n<\/ul>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
4<\/td>\n | CONTENTS <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | FOREWORD <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | INTRODUCTION <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 1 Scope 2 Normative references <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 4 Characteristics of lamps and lighting appliances 4.1 Product categories 4.2 System measurements and observations 4.2.1 General 4.2.2 Design, manufacture, and marketing <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 4.2.3 Durability and workmanship <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 4.2.4 Electrical characteristics <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 4.2.5 Photometric performance measures <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 4.2.6 Photometric durability measures <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 4.2.7 Self-declaration aspects 5 Product specification 5.1 General <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | 5.2 Applications Figures Figure 1 \u2013 The three components of a product specification Tables Table 1 \u2013 Applications of product specifications <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | 5.3 Quality assurance principles 5.3.1 General 5.3.2 Rationale for dividing quality, warranty, and performance 5.4 Product specification framework description 5.4.1 General <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | 5.4.2 Product specification template <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | Table 2 \u2013 Truth-in-advertising tolerance Table 3 \u2013 Safety and durability standards <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | Table 4 \u2013 Power quality standards for AC products Table 5 \u2013 End-user support standards <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | 5.4.3 Tolerances Table 6 \u2013 End-user support requirements Table 7 \u2013 Lighting service criteria for performance assessment <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | 5.4.4 Quality standards criteria <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | Table 8 \u2013 Truth-in-advertising criteria for quality standards Table 9 \u2013 Notes on common truth-in-advertising aspects <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | Table 10 \u2013 Safety and durability criteria for quality standards <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | Table 11 \u2013 Recommended level of water protection by product category Table 12 \u2013 Power quality criteria for quality standards <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | 5.4.5 Warranty requirements criteria 5.4.6 Performance criteria Table 13 \u2013 End-user support criteria for quality standards Table 14 \u2013 Criteria for warranty standards <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | Table 15 \u2013 Lighting service criteria for performance assessment <\/td>\n<\/tr>\n | ||||||
40<\/td>\n | 6 Quality test method (QTM) 6.1 General Table 16 \u2013 Lighting service benchmarks <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | 6.2 Applications 6.3 Sampling requirements 6.4 Laboratory requirements 6.5 Testing requirements Table 17 \u2013 Applications of product specifications <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | Table 18 \u2013 QTM testing requirements <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | 6.6 Recommended test programme 6.6.1 General Figure 2 \u2013 Recommended sequence of testing for QTM <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | 6.6.2 Reporting 7 Market check method (MCM) 7.1 General <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | 7.2 Applications 7.3 Sampling requirements 7.4 Laboratory requirements Table 19 \u2013 Applications of MCM results <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | 7.5 Testing requirements Table 20 \u2013 MCM testing requirements <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | 7.6 Recommended tests programme <\/td>\n<\/tr>\n | ||||||
50<\/td>\n | 7.7 Report requirements <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | Annexes Annex A (informative) Example quality standards and performance criteria for off-grid lighting market support programme qualification A.1 Overview A.2 Test requirements A.3 Quality standards Table A.1 \u2013 Truth-in-advertising tolerance <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | Table A.2 \u2013 Safety and durability standards <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | A.4 Warranty requirements A.5 Performance criteria Table A.3 \u2013 Power quality standards for AC products Table A.4 \u2013 End-user support requirements <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | Annex B (informative) Example quality standards, warranty requirements, and performance criteria for bulk procurement qualification (\u201csample tender\u201d) B.1 Overview B.2 Test requirements B.3 Product category requirements B.4 Quality standards Table B.1 \u2013 Truth-in-advertising tolerance <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | Table B.2 \u2013 Safety and durability standards <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | B.5 Warranty requirements B.6 Performance criteria B.7 Performance criteria tolerance Table B.3 \u2013 Power quality standards for AC products Table B.4 \u2013 End-user support requirements Table B.5 \u2013 Lighting service criteria for performance assessment <\/td>\n<\/tr>\n | ||||||
57<\/td>\n | Annex C (normative) Manufacturer self-reported information C.1 Background C.2 Outcomes C.3 Solicited information Table C.1 \u2013 Manufacturer self-reported information outcomes <\/td>\n<\/tr>\n | ||||||
58<\/td>\n | Annex D (normative) Product sampling D.1 Background D.2 Test outcomes D.3 Related tests D.4 Procedure Table D.1 \u2013 Product sampling outcomes <\/td>\n<\/tr>\n | ||||||
59<\/td>\n | Annex E (normative) Power supply requirements for testing E.1 Background E.2 Related tests E.3 Equipment requirements E.3.1 DC systems E.3.2 AC systems <\/td>\n<\/tr>\n | ||||||
60<\/td>\n | E.4 Reporting <\/td>\n<\/tr>\n | ||||||
61<\/td>\n | Annex F (normative) Visual screening F.1 Background F.2 Test outcomes F.3 Related tests F.4 Procedure F.4.1 Properties, features, and information Table F.1 \u2013 Visual screening test outcomes <\/td>\n<\/tr>\n | ||||||
63<\/td>\n | F.4.2 Specifications <\/td>\n<\/tr>\n | ||||||
64<\/td>\n | F.4.3 Functionality and internal inspection <\/td>\n<\/tr>\n | ||||||
65<\/td>\n | F.5 Reporting <\/td>\n<\/tr>\n | ||||||
68<\/td>\n | Annex G (normative) Sample preparation G.1 Background G.2 Test outcomes G.3 Related tests G.4 Procedure G.4.1 General G.4.2 Equipment requirements <\/td>\n<\/tr>\n | ||||||
69<\/td>\n | G.4.3 Test prerequisites G.4.4 Procedure <\/td>\n<\/tr>\n | ||||||
70<\/td>\n | G.5 Calculations G.6 Reporting <\/td>\n<\/tr>\n | ||||||
71<\/td>\n | Annex H (normative) Voltage and frequency settings, voltage measurement points, and product stabilization procedures H.1 Background H.2 Related tests H.3 Equipment requirements H.4 Procedure H.4.1 Test setup <\/td>\n<\/tr>\n | ||||||
72<\/td>\n | H.4.2 Standard operating voltages Figure H.1 \u2013 Test configuration Table H.1 \u2013 Standard operating voltage for several nominal system voltages <\/td>\n<\/tr>\n | ||||||
73<\/td>\n | H.4.3 Frequency selection H.4.4 Stabilization period <\/td>\n<\/tr>\n | ||||||
74<\/td>\n | H.5 Reporting Table H.2 \u2013 Voltage and current reporting requirements <\/td>\n<\/tr>\n | ||||||
75<\/td>\n | Annex I (normative) Light output I.1 Background I.2 Test outcomes I.3 Related tests I.4 Procedure Table I.1 \u2013 Light output test outcomes <\/td>\n<\/tr>\n | ||||||
76<\/td>\n | I.5 Calculations I.6 Reporting <\/td>\n<\/tr>\n | ||||||
77<\/td>\n | Annex J (normative) Light distribution J.1 Background J.2 Test outcomes J.3 Related tests J.4 Procedure J.5 Calculations Table J.1 \u2013 Light distribution test outcomes <\/td>\n<\/tr>\n | ||||||
78<\/td>\n | J.6 Reporting <\/td>\n<\/tr>\n | ||||||
79<\/td>\n | Annex K (normative) Input voltage range K.1 Background K.2 Test outcomes K.3 Related tests Table K.1 \u2013 Input voltage range test outcomes <\/td>\n<\/tr>\n | ||||||
80<\/td>\n | K.4 Procedure K.4.1 General K.4.2 Equipment requirements K.4.3 Test prerequisites K.4.4 Apparatus K.4.5 Procedure <\/td>\n<\/tr>\n | ||||||
81<\/td>\n | Table K.2 \u2013 Recommended operating voltage range and maximum allowable voltage by nominal operating voltage <\/td>\n<\/tr>\n | ||||||
82<\/td>\n | K.5 Calculations K.6 Reporting <\/td>\n<\/tr>\n | ||||||
83<\/td>\n | Table K.3 \u2013 Example table of operating voltage, current, voltage at DUT, and relative light output <\/td>\n<\/tr>\n | ||||||
84<\/td>\n | Annex L (normative) Lumen maintenance L.1 Background L.2 Test outcomes L.3 Related tests L.4 Procedure L.5 Calculations Table L.1 \u2013 Lumen maintenance test outcomes <\/td>\n<\/tr>\n | ||||||
85<\/td>\n | Annex M (normative) Cycling M.1 Background M.2 Test outcomes M.3 Related tests M.4 Procedure M.4.1 General M.4.2 Equipment requirements Table M.1 \u2013 Cycling test outcomes <\/td>\n<\/tr>\n | ||||||
86<\/td>\n | M.4.3 Test prerequisites M.4.4 Apparatus M.4.5 Procedure M.5 Calculations <\/td>\n<\/tr>\n | ||||||
87<\/td>\n | M.6 Reporting Figure M.1 \u2013 Plot of cycle life for 6 samples <\/td>\n<\/tr>\n | ||||||
88<\/td>\n | Annex N (normative) Mechanical durability N.1 Background N.2 Test outcomes Table N.1 \u2013 Mechanical durability test outcomes <\/td>\n<\/tr>\n | ||||||
89<\/td>\n | N.3 Related tests N.4 Procedures N.4.1 General N.4.2 Shipping vibration test <\/td>\n<\/tr>\n | ||||||
90<\/td>\n | N.5 Reporting <\/td>\n<\/tr>\n | ||||||
91<\/td>\n | Annex O (normative) Physical ingress and water protection O.1 Background O.2 Test outcomes Table O.1 \u2013 Water exposure and physical ingress protection test outcomes <\/td>\n<\/tr>\n | ||||||
92<\/td>\n | O.3 Related tests O.4 Procedure O.5 Reporting <\/td>\n<\/tr>\n | ||||||
93<\/td>\n | Annex P (normative) Power consumption and power quality P.1 Background P.2 Test outcomes P.3 Related tests P.4 Procedure P.4.1 DC power Table P.1 \u2013 AC power quality test outcomes <\/td>\n<\/tr>\n | ||||||
94<\/td>\n | P.4.2 AC power <\/td>\n<\/tr>\n | ||||||
95<\/td>\n | Figure P.1 \u2013 Test configuration for the AC power consumption and power quality test if an external power meter is used <\/td>\n<\/tr>\n | ||||||
96<\/td>\n | P.5 Reporting <\/td>\n<\/tr>\n | ||||||
97<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Recommendations for renewable energy and hybrid systems for rural electrification – Selection of lamps and lighting appliances for off-grid electricity systems<\/b><\/p>\n |