{"id":239275,"date":"2024-10-19T15:38:54","date_gmt":"2024-10-19T15:38:54","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-61810-32015\/"},"modified":"2024-10-25T10:20:55","modified_gmt":"2024-10-25T10:20:55","slug":"bs-en-61810-32015","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-61810-32015\/","title":{"rendered":"BS EN 61810-3:2015"},"content":{"rendered":"
This part of IEC 61810<\/span> <\/span> specifies special requirements and tests for elementary relays with forcibly guided contacts, also known as mechanically linked contacts. These special requirements apply in addition to the general requirements of IEC 61810\u20111<\/span> <\/span>.<\/p>\n This standard does not apply to electromechanical control circuit devices as described in IEC 60947\u20115\u20111<\/span>.<\/span><\/p>\n<\/div>\n IEC 61810\u20112\u20111<\/span> <\/span> provides guidelines for the assignment of reliability values.<\/p>\n<\/div>\n Contacts that are not mechanically linked (forcibly guided) are not considered in this standard.<\/p>\n<\/div>\n Electromechanical elementary relays – Relays with forcibly guided (mechanically linked) contacts<\/b><\/p>\nPDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 6<\/td>\n English
CONTENTS <\/td>\n<\/tr>\n\n 7<\/td>\n FOREWORD <\/td>\n<\/tr>\n \n 9<\/td>\n INTRODUCTION <\/td>\n<\/tr>\n \n 10<\/td>\n 1 Scope
2 Normative references
3 Terms and definitions <\/td>\n<\/tr>\n\n 11<\/td>\n 4 Functional requirements
4.1 Forcibly guided (mechanically linked) operation
4.2 Changeover contacts <\/td>\n<\/tr>\n\n 12<\/td>\n 4.3 Mechanical endurance
4.4 Electrical endurance
4.5 Operating conditions
4.5.1 Ambient temperature
4.5.2 Energizing quantity
4.6 Characteristic values and marking
4.6.1 Characteristic values
4.6.2 Marking
Figure 1 \u2013 Symbol for a forcibly guided (mechanically linked) contact set, type\u00a0A <\/td>\n<\/tr>\n\n 13<\/td>\n 5 Verification and type tests
5.1 Design verification
5.2 Type tests
Figure 2 \u2013 Symbols for use on type B relays <\/td>\n<\/tr>\n\n 14<\/td>\n 5.3 Test procedure
5.3.1 Testing for failure to open
5.3.2 Mechanical and electrical endurance <\/td>\n<\/tr>\n\n 15<\/td>\n Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" \n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n BSI<\/b><\/a><\/td>\n 2015<\/td>\n 18<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":239278,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[512,2641],"product_tag":[],"class_list":{"0":"post-239275","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-29-120-70","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/239275","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/239278"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=239275"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=239275"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=239275"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}