{"id":239103,"date":"2024-10-19T15:38:04","date_gmt":"2024-10-19T15:38:04","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-iso-193532016\/"},"modified":"2024-10-25T10:19:49","modified_gmt":"2024-10-25T10:19:49","slug":"bs-en-iso-193532016","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-iso-193532016\/","title":{"rendered":"BS EN ISO 19353:2016"},"content":{"rendered":"
This International Standard specifies methods for identifying fire hazards resulting from machinery and for performing a risk assessment.<\/p>\n
It gives the basic concepts and methodology of protective measures for fire prevention and protection to be taken during the design and construction of machinery. The measures consider the intended use and reasonably foreseeable misuse of the machine.<\/p>\n
It provides guidelines for consideration in reducing the risk of machinery fires to acceptable levels through machine design, risk assessment and operator instructions.<\/p>\n
This International Standard is not applicable to<\/p>\n
mobile machinery,<\/p>\n<\/li>\n
machinery designed to contain controlled combustion processes (e.g. internal combustion engines, furnaces), unless these processes can constitute the ignition source of a fire in other parts of the machinery or outside of this,<\/p>\n<\/li>\n
machinery used in potentially explosive atmospheres and explosion prevention and protection, and<\/p>\n<\/li>\n
fire detection and suppression systems that are integrated in building fire safety systems.<\/p>\n<\/li>\n<\/ul>\n
It is also not applicable to machinery or machinery components manufactured before the date of its publication.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
4<\/td>\n | European foreword <\/td>\n<\/tr>\n | ||||||
5<\/td>\n | Annex ZA (informative) Relationship between this European Standard and the Essential Requirements of EU Directive 2006\/42\/EC <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | Foreword <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 1\tScope 2\tNormative references 3\tTerms and definitions <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 4\tFire hazards 4.1\tGeneral <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 4.2\tCombustible materials 4.3\tOxidizers 4.4\tIgnition sources 5\tStrategy for fire risk assessment and risk reduction 5.1\tGeneral <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 5.2\tDetermination of the limits of the machinery 5.3\tIdentification of fire hazards <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 5.4\tRisk estimation <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 5.5\tRisk evaluation <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 5.6\tRisk reduction 5.6.1\tGeneral 5.6.2\tInherently safe design measures <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 5.6.3\tSafeguarding 5.6.4\tComplementary protective measures <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 6\tProcedure for the selection of complementary protective measures 6.1\tGeneral 6.1.1\tUse of the procedure 6.1.2\tDetermination of the residual risk level <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 6.1.3\tSpecification of requirements for the choice of fire detection and fire suppression system 6.1.4\tSpecification of safety and performance requirements 6.1.5\tSelection of system parts and suitable fire-extinguishing agent 6.1.6\tDecision on the need for further complementary protective measures 6.1.7\tValidation 6.2\tSelection of the fire prevention and protection system in relation to the expected risk level 6.2.1\tGeneral 6.2.2\tInjury to persons <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 6.2.3\tSafety considerations 6.2.4\tSelection of system parts 6.2.5\tSelection of fire-extinguishing agent <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 6.2.6\tValidation 7\tInformation for use <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | Annex\u00a0A (informative) Examples of ignition sources <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | Annex\u00a0B (informative) Examples of machines and their typical fire-related hazards <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | Annex\u00a0C (informative) Example for the design of a fire suppression system integrated in machinery <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | Annex\u00a0D (informative) Example for the risk assessment and risk reduction of a machining centre for the machining of metallic materials <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | Annex\u00a0E (informative) Fire risk reduction measures <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Safety of machinery. Fire prevention and fire protection<\/b><\/p>\n |