{"id":186296,"date":"2024-10-19T11:41:46","date_gmt":"2024-10-19T11:41:46","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/icc-iecc-commentary-2018-1stprint\/"},"modified":"2024-10-25T04:05:59","modified_gmt":"2024-10-25T04:05:59","slug":"icc-iecc-commentary-2018-1stprint","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/icc\/icc-iecc-commentary-2018-1stprint\/","title":{"rendered":"ICC IECC Commentary 2018 1stPrint"},"content":{"rendered":"

This comprehensive publication provides a convenient reference for regulations in the 2018 International Energy Conservation Code\u00ae (IECC\u00ae). The commentary series is presented in an easy-to-understand format. Every chapter begins with “General Comments” and “Purpose” sections followed by code and commentary to subsequent sections, tables and figures. This in-depth publication focuses on providing the full meaning and implications of the 2018 IECC\u00ae. The commentaries are designed to suggest the most effective method of application, and the consequences of not adhering to the code. This is an excellent reference for code officials, engineers, architects, inspectors, plans examiners, contractors and anyone who needs a better understanding of the 2018 IECC\u00ae.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\n2018 IECC\u00ae CODE AND COMMENTARY <\/td>\n<\/tr>\n
2<\/td>\n2018 IECC\u00ae CODE AND COMMENTARY TITLE PAGE <\/td>\n<\/tr>\n
3<\/td>\nCOPYRIGHT <\/td>\n<\/tr>\n
4<\/td>\nPREFACE <\/td>\n<\/tr>\n
6<\/td>\nTABLE OF CONTENTS <\/td>\n<\/tr>\n
8<\/td>\nIECC\u2014COMMERCIAL PROVISIONS
TABLE OF CONTENTS <\/td>\n<\/tr>\n
10<\/td>\nCHAPTER 1 [CE]: SCOPE AND ADMINISTRATION
GENERAL COMMENTS <\/td>\n<\/tr>\n
11<\/td>\nPURPOSE
PART 1\u2014SCOPE AND APPLICATION
SECTION C101 SCOPE AND GENERAL REQUIREMENTS <\/td>\n<\/tr>\n
12<\/td>\nCOMMENTARY FIGURE C101.4.1 MIXED BUILDING <\/td>\n<\/tr>\n
13<\/td>\nSECTION C102 ALTERNATIVE MATERIALS, DESIGN AND METHODS OF CONSTRUCTION AND EQUIPMENT <\/td>\n<\/tr>\n
14<\/td>\nPART 2\u2014ADMINISTRATION AND ENFORCEMENT
SECTION C103 CONSTRUCTION DOCUMENTS <\/td>\n<\/tr>\n
17<\/td>\nSECTION C104 FEES <\/td>\n<\/tr>\n
18<\/td>\nSECTION C105 INSPECTIONS <\/td>\n<\/tr>\n
20<\/td>\nSECTION C106 VALIDITY
SECTION C107 REFERENCED STANDARDS <\/td>\n<\/tr>\n
21<\/td>\nSECTION C108 STOP WORK ORDER
SECTION C109 BOARD OF APPEALS
BIBLIOGRAPHY <\/td>\n<\/tr>\n
22<\/td>\nCHAPTER 2 [CE]: DEFINITIONS
GENERAL COMMENTS
PURPOSE
SECTION C201 GENERAL
SECTION C202 GENERAL DEFINITIONS <\/td>\n<\/tr>\n
42<\/td>\nCHAPTER 3 [CE]: GENERAL REQUIREMENTS
GENERAL COMMENTS
PURPOSE
DISCUSSION AND DEVELOPMENT OF THE CLIMATE ZONE MAP <\/td>\n<\/tr>\n
43<\/td>\nSECTION C301 CLIMATE ZONES <\/td>\n<\/tr>\n
45<\/td>\nFIGURE C301.1 CLIMATE ZONES <\/td>\n<\/tr>\n
46<\/td>\nCOMMENTARY FIGURE C301.3 CLIMATE ZONE DEFINITIONS <\/td>\n<\/tr>\n
47<\/td>\nTABLE C301.3(1) INTERNATIONAL CLIMATE ZONE DEFINITIONS
TABLE C301.3(2) INTERNATIONAL CLIMATE ZONE DEFINITIONS <\/td>\n<\/tr>\n
48<\/td>\nTABLE C301.1 CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n
49<\/td>\nTABLE C301.1\u2014continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n
50<\/td>\nTABLE C301.1\u2014continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n
51<\/td>\nTABLE C301.1\u2014continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n
52<\/td>\nTABLE C301.1\u2014continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n
53<\/td>\nTABLE C301.1\u2014continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n
54<\/td>\nTABLE C301.1\u2014continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n
55<\/td>\nTABLE C301.1\u2014continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n
56<\/td>\nTABLE C301.1\u2014continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n
57<\/td>\nTABLE C301.1\u2014continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n
58<\/td>\nTABLE C301.1\u2014continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n
59<\/td>\nTABLE C301.1\u2014continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n
60<\/td>\nTABLE C301.1\u2014continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n
61<\/td>\nSECTION C302 DESIGN CONDITIONS
SECTION C303 MATERIALS, SYSTEMS AND EQUIPMENT <\/td>\n<\/tr>\n
62<\/td>\nCOMMENTARY FIGURE C303.1.1 SAMPLE CERTIFICATE OF INSULATION <\/td>\n<\/tr>\n
64<\/td>\nCOMMENTARY FIGURE C303.1.3(1) SAMPLE NATIONAL FENESTRATION RATING COUNCIL (NFRC) LABEL <\/td>\n<\/tr>\n
65<\/td>\nTABLE C303.1.3(1) DEFAULT GLAZED WINDOW, GLASS DOOR AND SKYLIGHT U-FACTORS
TABLE C303.1.3(2) DEFAULT OPAQUE DOOR U-FACTORS
TABLE C303.1.3(3) DEFAULT GLAZED FENESTRATION SHGC AND VT
COMMENTARY FIGURE C303.1.3(2) VISUALLY VERIFIABLE WINDOW CHARACTERISTICS <\/td>\n<\/tr>\n
67<\/td>\nBIBLIOGRAPHY <\/td>\n<\/tr>\n
68<\/td>\nCHAPTER 4 [CE]: COMMERCIAL ENERGY EFFICIENCY
GENERAL COMMENTS
COMMENTARY FIGURE 4C(1) EXAMPLES OF BUILDING TYPES COVERED BY CHAPTER 4 CE <\/td>\n<\/tr>\n
69<\/td>\nPURPOSE
SECTION C401 GENERAL <\/td>\n<\/tr>\n
70<\/td>\nSECTION C402 BUILDING ENVELOPE REQUIREMENTS <\/td>\n<\/tr>\n
71<\/td>\nCOMMENTARY FIGURE C402.1 GRAPHIC SUMMARY OF ENVELOPE REQUIREMENTS <\/td>\n<\/tr>\n
74<\/td>\nCOMMENTARY FIGURE C402.1.4 EXAMPLE OF U-FACTOR METHOD
COMMENTARY FIGURE C402.1.3 HOW TO MEASURE SURFACE AREAS (SEE COMMENTARY FIGURE C402.1) <\/td>\n<\/tr>\n
75<\/td>\nTABLE C402.1.3 OPAQUE THERMAL ENVELOPE INSULATION COMPONENT MINIMUM REQUIREMENTS, R-VALUE METHODa <\/td>\n<\/tr>\n
76<\/td>\nTABLE C402.1.4 OPAQUE THERMAL ENVELOPE ASSEMBLY MAXIMUM REQUIREMENTS, U-FACTOR METHODa <\/td>\n<\/tr>\n
77<\/td>\nEQUATION 4-1
EQUATION 4-2
TABLE C402.1.4.1 EFFECTIVE R-VALUES FOR STEEL STUD WALL ASSEMBLIES <\/td>\n<\/tr>\n
79<\/td>\nCOMMENTARY FIGURE C402.1.5 COMPONENT PERFORMANCE EXAMPLE <\/td>\n<\/tr>\n
80<\/td>\nCOMMENTARY FIGURE C402.2.1 REQUIREMENT FOR ROOFS <\/td>\n<\/tr>\n
81<\/td>\nCOMMENTARY FIGURE C402.2.2 REQUIREMENTS FOR EXTERIOR ABOVE GRADE WALLS <\/td>\n<\/tr>\n
83<\/td>\nCOMMENTARY FIGURE C402.2.3 R-VALUE REQUIREMENTS FOR FLOORS <\/td>\n<\/tr>\n
84<\/td>\nCOMMENTARY FIGURE C402.2.4 REQUIREMENT FOR INSULATING SLABS ON GRADE <\/td>\n<\/tr>\n
85<\/td>\nCOMMENTARY FIGURE C402.2.5 R-VALUE REQUIREMENTS FOR BELOW GRADE WALLS <\/td>\n<\/tr>\n
86<\/td>\nEQUATION 4-3
TABLE C402.3 MINIMUM ROOF REFLECTANCE AND EMITTANCE OPTIONSa <\/td>\n<\/tr>\n
87<\/td>\nTABLE C402.4 BUILDING ENVELOPE FENESTRATION MAXIMUM U-FACTOR AND SHGC REQUIREMENTS <\/td>\n<\/tr>\n
88<\/td>\nEQUATION 4-4 <\/td>\n<\/tr>\n
89<\/td>\nEQUATION 4-5 <\/td>\n<\/tr>\n
90<\/td>\nCOMMENTARY FIGURE C402.4.3 WINDOW PROJECTION FACTOR <\/td>\n<\/tr>\n
93<\/td>\nCOMMENTARY FIGURE C402.5.1.1 REQUIREMENTS FOR SEALING THE BUILDING ENVELOPE <\/td>\n<\/tr>\n
94<\/td>\nTABLE C402.5.2 MAXIMUM AIR LEAKAGE RATE FOR FENESTRATION ASSEMBLIES <\/td>\n<\/tr>\n
96<\/td>\nCOMMENTARY FIGURE C402.5.7 VESTIBULES <\/td>\n<\/tr>\n
97<\/td>\nSECTION C403 BUILDING MECHANICAL SYSTEMS
COMMENTARY FIGURE C402.5.8 IC-RATED RECESSED LIGHT <\/td>\n<\/tr>\n
103<\/td>\nTABLE C403.3.2(1) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS <\/td>\n<\/tr>\n
104<\/td>\nTABLE C403.3.2(1)\u2014continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS <\/td>\n<\/tr>\n
105<\/td>\nTABLE C403.3.2(2) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS <\/td>\n<\/tr>\n
106<\/td>\nTABLE C403.3.2(2)\u2014continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS <\/td>\n<\/tr>\n
107<\/td>\nTABLE C403.3.2(3) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS, SINGLE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS AND ROOM AIR-CONDITIONER HEAT PUMPS <\/td>\n<\/tr>\n
108<\/td>\nTABLE C403.3.2(3)\u2014continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS, SINGLE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS AND ROOM AIR-CONDITIONER HEAT PUMPS
TABLE C403.3.2(4) WARM-AIR FURNACES AND COMBINATION WARM-AIR FURNACES\/AIR-CONDITIONING UNITS, WARM-AIR DUCT FURNACES AND UNIT HEATERS, MINIMUM EFFICIENCY REQUIREMENTS <\/td>\n<\/tr>\n
109<\/td>\nTABLE C403.3.2(5) MINIMUM EFFICIENCY REQUIREMENTS: GAS- AND OIL-FIRED BOILERS
TABLE C403.3.2(6) MINIMUM EFFICIENCY REQUIREMENTS: CONDENSING UNITS, ELECTRICALLY OPERATED <\/td>\n<\/tr>\n
110<\/td>\nTABLE C403.3.2(7) WATER CHILLING PACKAGES \u2013 EFFICIENCY REQUIREMENTSa, b, d <\/td>\n<\/tr>\n
111<\/td>\nTABLE C403.3.2(8) MINIMUM EFFICIENCY REQUIREMENTS: HEAT REJECTION EQUIPMENT <\/td>\n<\/tr>\n
112<\/td>\nTABLE C403.3.2(9) MINIMUM EFFICIENCY AIR CONDITIONERS AND CONDENSING UNITS SERVING COMPUTER ROOMS
TABLE C403.3.2(10) HEAT TRANSFER EQUIPMENT <\/td>\n<\/tr>\n
113<\/td>\nEQUATION 4-6
EQUATION 4-7
TABLE C403.3.3 MAXIMUM HOT GAS BYPASS CAPACITY <\/td>\n<\/tr>\n
114<\/td>\nTABLE C403.3.4 BOILER TURNDOWN
COMMENTARY FIGURE C403.4.1 THERMOSTAT TEMPERATURE CONTROL <\/td>\n<\/tr>\n
115<\/td>\nCOMMENTARY FIGURE C403.4.1(1) SEPARATE COOLING AND HEATING SYSTEMS WITHIN A GROUP OF ZONES <\/td>\n<\/tr>\n
116<\/td>\nCOMMENTARY FIGURE C403.4.1(2) INDEPENDENT PERIMETER ZONE HEATING SYSTEM <\/td>\n<\/tr>\n
118<\/td>\nCOMMENTARY FIGURE C403.4.1.2 DEAD BAND THERMOSTAT CONTROL <\/td>\n<\/tr>\n
123<\/td>\nTABLE C403.4.4 VARIABLE SPEED DRIVE (VSD) REQUIREMENTS FOR DEMAND-CONTROLLED PUMPS <\/td>\n<\/tr>\n
124<\/td>\nTABLE C403.5(1) MINIMUM CHILLED-WATER SYSTEM COOLING CAPACITY FOR DETERMINING ECONOMIZER COOLING REQUIREMENTS <\/td>\n<\/tr>\n
125<\/td>\nTABLE C403.5(2) EQUIPMENT EFFICIENCY PERFORMANCE EXCEPTION FOR ECONOMIZERS <\/td>\n<\/tr>\n
126<\/td>\nTABLE C403.5.1 DX COOLING STAGE REQUIREMENTS FOR MODULATING AIRFLOW UNITS
COMMENTARY FIGURE C403.5.1(1) “STRAINER-CYCLE” WATER ECONOMIZER <\/td>\n<\/tr>\n
127<\/td>\nCOMMENTARY FIGURE C403.5.1(2) WATER PRECOOLING ECONOMIZER WITH TWO-WAY VALVES
COMMENTARY FIGURE C403.5.1(3) AIR PRECOOLING WATER ECONOMIZER <\/td>\n<\/tr>\n
128<\/td>\nCOMMENTARY FIGURE C403.5.3 AIR ECONOMIZER OPERATION <\/td>\n<\/tr>\n
129<\/td>\nTABLE C403.5.3.3 HIGH-LIMIT SHUTOFF CONTROL SETTING FOR AIR ECONOMIZERS <\/td>\n<\/tr>\n
137<\/td>\nTABLE C403.7.4(1) ENERGY RECOVERY REQUIREMENT (Ventilation systems operating less than 8,000 hours per year)
TABLE C403.7.4(2) ENERGY RECOVERY REQUIREMENT (Ventilation systems operating not less than 8,000 hours per year) <\/td>\n<\/tr>\n
138<\/td>\nTABLE C403.7.5 MAXIMUM NET EXHAUST FLOW RATE, CFM PER LINEAR FOOT OF HOOD LENGTH <\/td>\n<\/tr>\n
141<\/td>\nTABLE C403.8.1(1) FAN POWER LIMITATION <\/td>\n<\/tr>\n
142<\/td>\nTABLE C403.8.1(2) FAN POWER LIMITATION PRESSURE DROP ADJUSTMENT <\/td>\n<\/tr>\n
143<\/td>\nTABLE C403.8.5.1 COOLING SYSTEMS <\/td>\n<\/tr>\n
145<\/td>\nTABLE C403.10.1(1) MINIMUM EFFICIENCY REQUIREMENTS: COMMERCIAL REFRIGERATION <\/td>\n<\/tr>\n
146<\/td>\nTABLE C403.10.1(2) MINIMUM EFFICIENCY REQUIREMENTS: COMMERCIAL REFRIGERATORS AND FREEZERS <\/td>\n<\/tr>\n
147<\/td>\nTABLE C403.10.1(2)\u2014continued MINIMUM EFFICIENCY REQUIREMENTS: COMMERCIAL REFRIGERATORS AND FREEZERS <\/td>\n<\/tr>\n
149<\/td>\nTABLE C403.10.2.1(1) WALK-IN COOLER AND FREEZER DISPLAY DOOR EFFICIENCY REQUIREMENTS
TABLE C403.10.2.1(2) WALK-IN COOLER AND FREEZER NON DISPLAY DOOR EFFICIENCY REQUIREMENTSa
TABLE C403.10.2.1(3) WALK-IN COOLER AND FREEZER REFRIGERATION SYSTEM EFFICIENCY REQUIREMENTS <\/td>\n<\/tr>\n
151<\/td>\nCOMMENTARY FIGURE C403.11.1 DUCT INSULATION <\/td>\n<\/tr>\n
154<\/td>\nEQUATION 4-8 <\/td>\n<\/tr>\n
155<\/td>\nTABLE C403.11.3 MINIMUM PIPE INSULATION THICKNESS (in inches)a, c <\/td>\n<\/tr>\n
156<\/td>\nSECTION C404 SERVICE WATER HEATING (MANDATORY)
COMMENTARY FIGURE C404.1 ELEMENTS COVERED BY SECTION C404 <\/td>\n<\/tr>\n
158<\/td>\nTABLE C404.2 MINIMUM PERFORMANCE OF WATER-HEATING EQUIPMENT <\/td>\n<\/tr>\n
159<\/td>\nTABLE C404.2\u2014continued MINIMUM PERFORMANCE OF WATER-HEATING EQUIPMENT <\/td>\n<\/tr>\n
160<\/td>\nCOMMENTARY FIGURE C404.3(1) HEAT TRAP AND INSULATION REQUIREMENTS FOR NONCIRCULATING SYSTEMS <\/td>\n<\/tr>\n
161<\/td>\nCOMMENTARY FIGURE C404.3(2) HEAT TRAPS ON A TANK WITH CONNECTIONS ON THE BOTTOM
COMMENTARY FIGURE C404.3(3) HEAT TRAP THROUGH A FLEXIBLE PIPE LOOP
COMMENTARY FIGURE C404.4 HEAT TRAPS ON A TANK WITH CONNECTIONS ON SIDES <\/td>\n<\/tr>\n
162<\/td>\nTABLE C404.5.1 PIPING VOLUME AND MAXIMUM PIPING LENGTHS <\/td>\n<\/tr>\n
165<\/td>\nSECTION C405 ELECTRICAL POWER AND LIGHTING SYSTEMS <\/td>\n<\/tr>\n
169<\/td>\nCOMMENTARY FIGURE C405.2.1 REQUIRED LIGHTING CONTROLS <\/td>\n<\/tr>\n
171<\/td>\nEQUATION 4-9 <\/td>\n<\/tr>\n
172<\/td>\nCOMMENTARY FIGURE C405.2.2.2 LIGHT-REDUCTION CONTROLS <\/td>\n<\/tr>\n
174<\/td>\nFIGURE C405.2.3.2 SIDELIT ZONE <\/td>\n<\/tr>\n
175<\/td>\nFIGURE C405.2.3.3(1) TOPLIT ZONE
FIGURE C405.2.3.3(2) DAYLIGHT ZONE UNDER A ROOFTOP MONITOR <\/td>\n<\/tr>\n
176<\/td>\nFIGURE C405.2.3.3(3) DAYLIGHT ZONE UNDER A SLOPED ROOFTOP MONITOR <\/td>\n<\/tr>\n
179<\/td>\nEQUATION 4-10 <\/td>\n<\/tr>\n
181<\/td>\nTABLE C405.3.2(1) INTERIOR LIGHTING POWER ALLOWANCES: BUILDING AREA METHOD
TABLE C405.3.2(2) INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD <\/td>\n<\/tr>\n
182<\/td>\nTABLE C405.3.2(2)\u2014continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
TABLE C405.3.2(2)\u2014continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD <\/td>\n<\/tr>\n
183<\/td>\nTABLE C405.3.2(2)\u2014continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
EQUATION 4-11
COMMENTARY FIGURE C405.3.2(1) MULTIUSE FACILITY <\/td>\n<\/tr>\n
184<\/td>\nCOMMENTARY FIGURE C405.3.2(2) TOTAL LIGHTING POWER ALLOWANCE CALCULATION USING THE BUILDING AREA METHOD
COMMENTARY FIGURE C405.3.2(3) TOTAL LIGHTING POWER ALLOWANCE CALCULTION USING THE SPACE BY SPACE METHOD <\/td>\n<\/tr>\n
186<\/td>\nTABLE C405.4.2(1) EXTERIOR LIGHTING ZONES
TABLE C405.4.2(2) LIGHTING POWER ALLOWANCES FOR BUILDING EXTERIORS <\/td>\n<\/tr>\n
187<\/td>\nTABLE C405.4.2(3) INDIVIDUAL LIGHTING POWER ALLOWANCES FOR BUILDING EXTERIORS
COMMENTARY FIGURE C405.4.2 EXAMPLE OF EXTERIOR LIGHTING POWER ALLOWANCES <\/td>\n<\/tr>\n
188<\/td>\nTABLE C405.6 MINIMUM NOMINAL EFFICIENCY LEVELS FOR 10 CFR 431 LOW-VOLTAGE DRY-TYPE DISTRIBUTION TRANSFORMERS <\/td>\n<\/tr>\n
189<\/td>\nTABLE C405.7(1) MINIMUM NOMINAL FULL-LOAD EFFICIENCY FOR NEMA DESIGN A, NEMA DESIGN B, AND IEC DESIGN N MOTORS (EXCLUDING FIRE PUMP) ELECTRIC MOTORS AT 60 HZa, b <\/td>\n<\/tr>\n
190<\/td>\nTABLE C405.7(2) MINIMUM NOMINAL FULL-LOAD EFFICIENCY FOR NEMA DESIGN C AND IEC DESIGN H MOTORS AT 60 HZ a, b
TABLE C405.7(3) MINIMUM AVERAGE FULL-LOAD EFFICIENCY POLYPHASE SMALL ELECTRIC MOTORSa <\/td>\n<\/tr>\n
191<\/td>\nTABLE C405.7(4) MINIMUM AVERAGE FULL-LOAD EFFICIENCY FOR CAPACITOR-START CAPACITOR-RUN AND CAPACITOR-START INDUCTION-RUN SMALL ELECTRIC MOTORSa <\/td>\n<\/tr>\n
192<\/td>\nSECTION C406 ADDITIONAL EFFICIENCY PACKAGE OPTIONS <\/td>\n<\/tr>\n
194<\/td>\nSECTION C407 TOTAL BUILDING PERFORMANCE <\/td>\n<\/tr>\n
198<\/td>\nTABLE C407.5.1(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS <\/td>\n<\/tr>\n
199<\/td>\nTABLE C407.5.1(1)\u2014continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS <\/td>\n<\/tr>\n
200<\/td>\nTABLE C407.5.1(2) HVAC SYSTEMS MAP <\/td>\n<\/tr>\n
201<\/td>\nTABLE C407.5.1(3) SPECIFICATIONS FOR THE STANDARD REFERENCE DESIGN HVAC SYSTEM DESCRIPTIONS <\/td>\n<\/tr>\n
202<\/td>\nTABLE C407.5.1(4) NUMBER OF CHILLERS
TABLE C407.5.1(5) WATER CHILLER TYPES <\/td>\n<\/tr>\n
204<\/td>\nSECTION C408 MAINTENANCE INFORMATION AND SYSTEM COMMISSIONING <\/td>\n<\/tr>\n
206<\/td>\nFIGURE C408.2.4 COMMISSIONING COMPLIANCE CHECKLIST <\/td>\n<\/tr>\n
208<\/td>\nBIBLIOGRAPHY <\/td>\n<\/tr>\n
210<\/td>\nCHAPTER 5 [CE]: EXISTING BUILDINGS
GENERAL COMMENTS
PURPOSE
SECTION C501 GENERAL <\/td>\n<\/tr>\n
211<\/td>\nSECTION C502 ADDITIONS <\/td>\n<\/tr>\n
213<\/td>\nSECTION C503 ALTERATIONS <\/td>\n<\/tr>\n
215<\/td>\nSECTION C504 REPAIRS
SECTION C505 CHANGE OF OCCUPANCY OR USE <\/td>\n<\/tr>\n
218<\/td>\nCHAPTER 6 [CE]: REFERENCED STANDARDS
GENERAL COMMENTS
PURPOSE <\/td>\n<\/tr>\n
219<\/td>\nCOMMENTARY FIGURE 6 [CE] REFERENCED STANDARDS <\/td>\n<\/tr>\n
220<\/td>\nAAMA
AHAM
AHRI <\/td>\n<\/tr>\n
221<\/td>\nAMCA
ANSI
APSP
ASHRAE <\/td>\n<\/tr>\n
222<\/td>\nASME
ASTM
CRRC <\/td>\n<\/tr>\n
223<\/td>\nCSA
CTI
DASMA
DOE <\/td>\n<\/tr>\n
224<\/td>\nICC
IEEE
IES
ISO
NEMA <\/td>\n<\/tr>\n
225<\/td>\nNFPA
NFRC
SMACNA
UL
US-FTC
WDMA <\/td>\n<\/tr>\n
226<\/td>\nAPPENDIX CA: SOLAR-READY ZONE\u2014COMMERCIAL PROVISIONS
GENERAL COMMENTS
PURPOSE
SECTION CA101 SCOPE
SECTION CA102 GENERAL DEFINITION
SECTION CA103 SOLAR-READY ZONE <\/td>\n<\/tr>\n
228<\/td>\nINDEX <\/td>\n<\/tr>\n
238<\/td>\nIECC\u2014RESIDENTIAL PROVISIONS
TABLE OF CONTENTS <\/td>\n<\/tr>\n
240<\/td>\nCHAPTER 1 [RE]: SCOPE AND ADMINISTRATION
GENERAL COMMENTS <\/td>\n<\/tr>\n
241<\/td>\nPURPOSE
PART 1\u2014SCOPE AND APPLICATION
SECTION R101 SCOPE AND GENERAL REQUIREMENTS <\/td>\n<\/tr>\n
242<\/td>\nCOMMENTARY FIGURE R101.4.1 MIXED BUILDING <\/td>\n<\/tr>\n
243<\/td>\nSECTION R102 ALTERNATIVE MATERIALS, DESIGN AND METHODS OF CONSTRUCTION AND EQUIPMENT <\/td>\n<\/tr>\n
244<\/td>\nPART 2\u2014ADMINISTRATION AND ENFORCEMENT
SECTION R103 CONSTRUCTION DOCUMENTS <\/td>\n<\/tr>\n
246<\/td>\nSECTION R104 FEES <\/td>\n<\/tr>\n
247<\/td>\nSECTION R105 INSPECTIONS <\/td>\n<\/tr>\n
249<\/td>\nSECTION R106 VALIDITY <\/td>\n<\/tr>\n
250<\/td>\nSECTION R107 REFERENCED STANDARDS
SECTION R108 STOP WORK ORDER <\/td>\n<\/tr>\n
251<\/td>\nSECTION R109 BOARD OF APPEALS
BIBLIOGRAPHY <\/td>\n<\/tr>\n
252<\/td>\nCHAPTER 2 [RE]: DEFINITIONS
GENERAL COMMENTS
PURPOSE
SECTION R201 GENERAL
SECTION R202 GENERAL DEFINITIONS <\/td>\n<\/tr>\n
254<\/td>\nCOMMENTARY FIGURE R202(1) BASEMENT WALLS <\/td>\n<\/tr>\n
266<\/td>\nCHAPTER 3 [RE]: GENERAL REQUIREMENTS
GENERAL COMMENTS
PURPOSE
DISCUSSION AND DEVELOPMENT OF THE CLIMATE ZONE MAP <\/td>\n<\/tr>\n
267<\/td>\nSECTION R301 CLIMATE ZONES <\/td>\n<\/tr>\n
269<\/td>\nFIGURE R301.1 CLIMATE ZONES <\/td>\n<\/tr>\n
270<\/td>\nCOMMENTARY FIGURE R301.3 CLIMATE ZONE DEFINITIONS <\/td>\n<\/tr>\n
271<\/td>\nTABLE R301.3(1) INTERNATIONAL CLIMATE ZONE DEFINITIONS
TABLE R301.3(2) INTERNATIONAL CLIMATE ZONE DEFINITIONS <\/td>\n<\/tr>\n
272<\/td>\nTABLE R301.1 CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n
273<\/td>\nTABLE R301.1\u2014continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n
274<\/td>\nTABLE R301.1\u2014continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n
275<\/td>\nTABLE R301.1\u2014continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n
276<\/td>\nTABLE R301.1\u2014continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n
277<\/td>\nTABLE R301.1\u2014continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n
278<\/td>\nTABLE R301.1\u2014continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n
279<\/td>\nTABLE R301.1\u2014continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n
280<\/td>\nTABLE R301.1\u2014continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n
281<\/td>\nTABLE R301.1\u2014continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n
282<\/td>\nTABLE R301.1\u2014continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n
283<\/td>\nTABLE R301.1\u2014continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n
284<\/td>\nTABLE R301.1\u2014continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n
285<\/td>\nSECTION R302 DESIGN CONDITIONS
SECTION R303 MATERIALS, SYSTEMS AND EQUIPMENT <\/td>\n<\/tr>\n
286<\/td>\nCOMMENTARY FIGURE R303.1.1 SAMPLE CERTIFICATE OF INSULATION <\/td>\n<\/tr>\n
288<\/td>\nCOMMENTARY FIGURE R303.1.3(1) SAMPLE NATIONAL FENESTRATION RATING COUNCIL (NFRC) LABEL <\/td>\n<\/tr>\n
289<\/td>\nTABLE R303.1.3(1) DEFAULT GLAZED WINDOW, GLASS DOOR AND SKYLIGHT U-FACTORS
TABLE R303.1.3(2) DEFAULT OPAQUE DOOR U-FACTORS
TABLE R303.1.3(3) DEFAULT GLAZED FENESTRATION SHGC AND VT
COMMENTARY FIGURE R303.1.3(2) VISUALLY VERIFIABLE WINDO CHARACTERISTICS <\/td>\n<\/tr>\n
291<\/td>\nBIBLIOGRAPHY <\/td>\n<\/tr>\n
292<\/td>\nCHAPTER 4 [RE]: RESIDENTIAL ENERGY EFFICIENCY
GENERAL COMMENTS
PURPOSE
SECTION R401 GENERAL <\/td>\n<\/tr>\n
294<\/td>\nCOMMENTARY FIGURE R401.3 CERTIFICATE <\/td>\n<\/tr>\n
295<\/td>\nSECTION R402 BUILDING THERMAL ENVELOPE <\/td>\n<\/tr>\n
296<\/td>\nCOMMENTARY FIGURE R402.1(1) CONDITIONED ENVELOPE
COMMENTARY FIGURE R402.1(2) BUILDING ENVELOPE <\/td>\n<\/tr>\n
298<\/td>\nTABLE R402.1.2 INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENTa <\/td>\n<\/tr>\n
300<\/td>\nTABLE R402.1.4 EQUIVALENT U-FACTORSa <\/td>\n<\/tr>\n
301<\/td>\nCOMMENTARY FIGURE R402.1.4(1) EXAMPLE OF U-FACTOR CALCULATION IN TABLE R402.1.4
COMMENTARY FIGURE R402.1.4(2) EXAMPLE OF U-FACTOR ALTERNATIVE <\/td>\n<\/tr>\n
304<\/td>\nCOMMENTARY FIGURE R402.2.1(1) TYPICAL ROOF ASSEMBLY <\/td>\n<\/tr>\n
305<\/td>\nCOMMENTARY FIGURE R402.2.1(2) RAISED-HEEL TRUSS <\/td>\n<\/tr>\n
306<\/td>\nCOMMENTARY FIGURE R402.2.5(1) EXTERIOR INSULATION <\/td>\n<\/tr>\n
307<\/td>\nCOMMENTARY FIGURE R402.2.5(2) INTERIOR INSULATION
TABLE R402.2.6 STEEL-FRAME CEILING, WALL AND FLOOR INSULATION R-VALUES <\/td>\n<\/tr>\n
309<\/td>\nCOMMENTARY FIGURE R402.2.8 SLAB INSULATION METHODS
COMMENTARY FIGURE R402.2.9(1) WALKOUT BASEMENT <\/td>\n<\/tr>\n
310<\/td>\nCOMMENTARY FIGURE R402.2.9(2) EXTERIOR BASEMENT INSULATION <\/td>\n<\/tr>\n
312<\/td>\nCOMMENTARY FIGURE R402.2.11 CRAWL SPACE WALL INSULATION <\/td>\n<\/tr>\n
315<\/td>\nCOMMENTARY FIGURE R402.4 TYPICAL SOURCES OF AIR LEAKAGE IN THE HOME <\/td>\n<\/tr>\n
317<\/td>\nTABLE R402.4.1.1 AIR BARRIER AND INSULATION INSTALLATIONa <\/td>\n<\/tr>\n
318<\/td>\nCOMMENTARY FIGURE R402.4.5 IC-RATED RECESSED LIGHT <\/td>\n<\/tr>\n
319<\/td>\nSECTION R403 SYSTEMS <\/td>\n<\/tr>\n
324<\/td>\nTABLE R403.6.1 WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACYa <\/td>\n<\/tr>\n
325<\/td>\nSECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS <\/td>\n<\/tr>\n
326<\/td>\nSECTION R405 SIMULATED PERFORMANCE ALTERNATIVE (PERFORMANCE) <\/td>\n<\/tr>\n
334<\/td>\nTABLE R405.5.2(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS <\/td>\n<\/tr>\n
335<\/td>\nTABLE R405.5.2(1)\u2014continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS <\/td>\n<\/tr>\n
336<\/td>\nTABLE R405.5.2(1)\u2014continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
TABLE R405.5.2(2) DEFAULT DISTRIBUTION SYSTEM EFFICIENCIES FOR PROPOSED DESIGNSa <\/td>\n<\/tr>\n
337<\/td>\nSECTION R406 ENERGY RATING INDEX COMPLIANCE ALTERNATIVE <\/td>\n<\/tr>\n
338<\/td>\nEQUATION 4-1
TABLE R406.4 MAXIMUM ENERGY RATING INDEX <\/td>\n<\/tr>\n
340<\/td>\nBIBLIOGRAPHY <\/td>\n<\/tr>\n
342<\/td>\nCHAPTER 5 [RE]: EXISTING BUILDINGS
GENERAL COMMENTS
PURPOSE
SECTION R501 GENERAL <\/td>\n<\/tr>\n
343<\/td>\nSECTION R502 ADDITIONS <\/td>\n<\/tr>\n
345<\/td>\nSECTION R503 ALTERATIONS <\/td>\n<\/tr>\n
347<\/td>\nSECTION R504 REPAIRS
SECTION R505 CHANGE OF OCCUPANCY OR USE <\/td>\n<\/tr>\n
350<\/td>\nCHAPTER 6 [RE]: REFERENCED STANDARDS
GENERAL COMMENTS
PURPOSE <\/td>\n<\/tr>\n
351<\/td>\nCOMMENTARY FIGURE 6 [RE] REFERENCED STANDARDS <\/td>\n<\/tr>\n
352<\/td>\nAAMA
ACCA
APSP
ASHRAE
ASTM <\/td>\n<\/tr>\n
353<\/td>\nCSA
DASMA
HVI
ICC <\/td>\n<\/tr>\n
354<\/td>\nIEEE
NFPA
NFRC
RESNET <\/td>\n<\/tr>\n
355<\/td>\nUL
US-FTC
WDMA <\/td>\n<\/tr>\n
356<\/td>\nAPPENDIX RA: SOLAR-READY PROVISIONS\u2014DETACHED ONE- AND TWO-FAMILY DWELLINGS AND TOWNHOUSES
GENERAL COMMENTS
PURPOSE
SECTION RA101 SCOPE
SECTION RA102 GENERAL DEFINITION
SECTION RA103 SOLAR-READY ZONE <\/td>\n<\/tr>\n
358<\/td>\nINDEX <\/td>\n<\/tr>\n
364<\/td>\nGET IMMEDIATE DOWNLOADS <\/td>\n<\/tr>\n
365<\/td>\nICC PLAN REVIEW SERVICES <\/td>\n<\/tr>\n
366<\/td>\nICC EVALUATION SERVICE <\/td>\n<\/tr>\n
367<\/td>\nDISCOVER THE ICC ASSESSMENT CENTER, FEATURING PRONTO\u2122 <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

International Energy Conservation Code and Commentary<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ICC<\/b><\/a><\/td>\n2018<\/td>\n367<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":186298,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2670],"product_tag":[],"class_list":{"0":"post-186296","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-icc","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/186296","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/186298"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=186296"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=186296"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=186296"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}