{"id":111858,"date":"2024-10-18T16:17:33","date_gmt":"2024-10-18T16:17:33","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-c57-100-2012\/"},"modified":"2024-10-24T22:02:52","modified_gmt":"2024-10-24T22:02:52","slug":"ieee-c57-100-2012","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-c57-100-2012\/","title":{"rendered":"IEEE C57.100 2012"},"content":{"rendered":"
Revision Standard – Active. A test procedure to provide a uniform method for investigating the effect of operating temperature on the life expectancy of liquid-immersed transformers is provided. The test procedures are intended to provide data for the selection of a limiting hottest-spot temperature for rating purposes, provide data which may serve as the basis for a guide for loading, and permit the comparative evaluation of a proposed insulation system with reference to a system that has proven to be acceptable in service.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | IEEE Std C57.100-2011 Front Cover <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | Notice to users Laws and regulations Copyrights Updating of IEEE documents Errata Interpretations Patents <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | Participants <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | Contents <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | Important Notice 1. Overview 1.1 Scope 1.2 Purpose <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 2. Normative references 3. Definitions 3.1 Industry-proven insulation system <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 4. Aging influences 5. Minimum life expectancy <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 6. Criteria for end of life\u2014Distribution transformer and power transformer model 7. Test temperatures <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 8. Test methods and specimens 8.1 Distribution transformer 8.2 Power transformer model <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 8.3 Relative testing specimens 9. Test period 9.1 Hottest spot test temperature 9.2 Temperature of liquid <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 9.3 Duration of test period 9.4 Cycling 9.5 Calculation of aging caused by heating and cooling <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 10. End-point tests 10.1 Distribution transformers 10.2 Power transformers 10.3 Abnormalities 11. Test results <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 11.1 Data presentation 11.2 Test report <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 11.3 Example calculation of life equation <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 12. Applicability of test results <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | Annex A (normative) Materials testing for aging of liquid-immersed transformer insulation A.1 Purpose A.2 Test temperatures and test periods A.2.1 Single-point sealed tube aging <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | A.2.2 Three-point aging <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | A.3 Limiting factor\u2014insulation system A.4 Comparative evaluation A.4.1 Single point aging <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | A.4.2 Three-point aging A.4.2.1 Determination of end-of-life criteria for candidate system In this particular example, the end-of-life criteria is 21.9% retained tensile strength, which is the average of the results shown in Table A.2. A.4.2.1.1 Test program for the candidate system A.4.2.1.2 Determination of time-temperature points <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | A.4.2.1.3 Determination of the life equation <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | Annex B (normative) Materials testing\u2014standard test procedure for sealed tube aging of liquid-immersed transformer insulation B.1 Test samples <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | Annex C (normative) Materials testing\u2014standard test procedure for dual-temperature sealed tube aging of liquid-immersed transformer insulation C.1 Purpose C.2 Test samples <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | Annex D (informative) Historical background information D.1 Distribution transformer and power transformer model test result discussion from IEEE Std C57.100-1999 [B12] D.2 Background discussion from references <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | Annex E (informative) Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" IEEE Standard Test Procedure for Thermal Evaluation of Insulation Systems for Liquid-Immersed Distribution and Power Transformers<\/b><\/p>\n |