IEEE C57.13-2016
$59.58
IEEE Standard Requirements for Instrument Transformers
Published By | Publication Date | Number of Pages |
IEEE | 2016 |
Revision Standard – Active. Electrical, dimensional, and mechanical characteristics are covered, taking into consideration certain safety features, for current and inductively coupled voltage transformers of types generally used in the measurement of electricity and the control of equipment associated with the generation, transmission, and distribution of alternating current. The aim is to provide a basis for performance and interchangeability of equipment covered and to assist in the proper selection of such equipment. Safety precautions are also addressed. Accuracy classes for metering service are provided. The test code covers measurement and calculation of ratio and phase angle, demagnetization, impedance and excitation measurements, polarity determination, resistance measurements, short-time characteristics, temperature rise tests, dielectric tests, and measurement of open-circuit voltage of current transformers.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | IEEE Std C57.13™-2016 Front cover |
2 | Title page |
4 | Important Notices and Disclaimers Concerning IEEE Standards Documents |
7 | Participants |
9 | Introduction |
10 | Contents |
12 | IMPORTANT NOTICES 1. Overview 1.1 Scope 1.2 Purpose |
13 | 2. Normative references 3. Definitions |
14 | 4. General requirements 4.1 Service conditions 4.1.1 Unusual temperature and altitude service conditions 4.1.1.1 30 ºC average ambient temperature 4.1.1.2 55 ºC average ambient temperature 4.1.2 Unusual temperature and altitude service conditions |
15 | 4.1.3 Other conditions that may affect design and application 4.2 Effect of air density on flashover voltage |
16 | 4.3 Frequency 4.4 Effect of altitude on temperature rise and effect of ambient temperature on permissible loading 4.4.1 Loading of current transformers at less than rated current at high altitudes 4.4.2 Operation of current transformers at other than 30 °C ambient temperature |
17 | 4.4.3 Loading of voltage transformers at higher altitudes or higher ambient temperatures 4.5 Basic impulse insulation levels, dielectric tests, and outdoor instrument transformer creepage distance and wet test |
20 | 4.6 Temperature rise |
21 | 4.7 Capacitance and dissipation factor requirements 4.8 Classification of tests |
22 | 4.8.1 Test requirements |
23 | 4.8.2 Special tests for gas-filled instrument transformers 4.8.3 Other tests 4.9 Construction 4.9.1 Polarity and terminal marking |
24 | 4.9.2 Ground shield requirements 4.9.3 Symbols |
26 | 5. Accuracy classes for metering 5.1 Basis for accuracy classes |
27 | 5.2 Expression of transformer correction factor at 0.6 power factor (lagging) of metered load 5.3 Standard accuracy classes |
28 | 5.4 Limiting values of ratio correction factor and phase angle for standard accuracy classes |
31 | 6. Current transformers 6.1 Terms in which ratings shall be expressed 6.2 Standard burdens 6.3 Accuracy ratings for metering |
32 | 6.3.1 Tapped-secondary or multiple-ratio current transformer accuracy rating |
33 | 6.4 Accuracy ratings for relaying |
34 | 6.4.1 Basis for relaying accuracy ratings 6.4.1.1 C classification 6.4.1.2 T classification 6.4.1.3 Secondary terminal voltage |
35 | 6.4.1.4 X classification 6.4.1.5 Transient performance classifications 6.4.2 Tapped secondary or multi ratio current transformer 6.5 Continuous thermal current rating factors based on 30 °C average ambient air temperature 6.6 Short-time current ratings 6.6.1 Short-time mechanical current rating 6.6.2 Short-time thermal current rating |
36 | 6.6.3 Short-time and continuous current ratings of window-type or bushing-type current transformers 6.7 Secondary winding-induced voltages 6.7.1 Operation with secondary circuit open 6.7.2 Induced voltage test |
37 | 6.8 Nameplates 6.9 Terminals 6.10 Application data |
38 | 6.10.1 Data for metering applications 6.10.2 Data for relaying applications |
40 | 6.11 Routine accuracy tests |
41 | 7. Voltage transformers 7.1 Terms in which ratings shall be expressed |
45 | 7.2 Standard burdens |
46 | 7.3 Accuracy ratings 7.3.1 Assignment of accuracy ratings 7.3.2 Accuracy classification for voltage transformers with two secondary windings or tapped secondary windings 7.4 Thermal burden ratings |
47 | 7.5 Nameplates 7.6 Terminals 7.7 Short-circuit capability |
48 | 7.8 Application data 7.9 Induced voltage test 7.10 Routine accuracy tests 8. Test procedures applicable to instrument transformers |
49 | 8.1 Ratio and phase angle measurement and calculations 8.1.1 Uncertainty limits 8.1.2 General |
50 | 8.1.3 Special considerations in calibration for metering purposes 8.2 Impedance, excitation, and composite error measurements 8.2.1 Impedance measurements |
51 | 8.2.2 Impedance voltage 8.2.3 Exciting current and excitation loss measurements |
52 | 8.2.3.1 Composite error measurements |
53 | 8.2.4 Measurements for high magnetic flux densities 8.3 Polarity 8.3.1 Direct comparison of winding voltages |
54 | 8.4 Resistance measurements |
55 | 8.4.1 Voltmeter ammeter methods 8.4.2 Bridge methods |
56 | 8.4.3 Reference temperature measurements 8.5 Dielectric tests 8.5.1 Factory dielectric tests 8.5.2 Dielectric tests by the user 8.5.3 Applied voltage tests |
57 | 8.5.4 Induced voltage tests |
58 | 8.6 Partial discharge measurement |
59 | 8.6.1 Partial discharge measurement for voltage transformers for a nominal system voltage of 72 kV and below |
60 | 8.6.2 Partial discharge measurement for current transformers for a nominal system voltage of 72 kV and below 9. Test procedures applicable to current transformers 9.1 Ratio and phase angle measurement and calculations 9.1.1 Accuracy calculations for current transformers |
63 | 9.1.2 Calculation of current transformer performance from secondary excitation characteristics and equivalent circuits 9.1.2.1 Determination of current transformer turns ratio 9.1.2.2 Calculation of current transformer ratio error and phase angle |
64 | 9.1.2.3 Calculation of current transformer composite error 9.1.3 Application of calculating methods to type C relaying accuracy current transformers 9.2 Demagnetization |
65 | 9.3 Impedance measurements 9.3.1 Current transformer short-circuit impedance measurements |
66 | 9.4 Polarity 9.4.1 Comparison with a transformer of known polarity |
67 | 10. Test procedures applicable to voltage transformers 10.1 Ratio and phase angle measurement and calculations 10.1.1 Accuracy calculations for voltage transformers 10.1.2 Calculation of voltage transformer ratio and phase angle from known zero and rated burden data |
69 | 10.2 Impedance measurements 10.2.1 Voltage transformer short-circuit impedance measurements |
70 | 10.3 Polarity 10.3.1 Comparison with a transformer of known polarity |
71 | 11. Type test procedures applicable to instrument transformers 11.1 Short-time characteristics 11.1.1 Short-time mechanical rating tests 11.1.2 Thermal short-time rating calculations |
73 | 11.2 Temperature rise tests 11.2.1 General 11.2.2 Ambient or cooling air temperature |
74 | 11.2.3 Temperature rise measurements |
75 | 11.2.4 Determination of winding temperature at time of shutdown 11.2.5 Determination of average temperature by the resistance method 11.2.6 Determination of temperature rise from temperature measurements 11.2.7 Correction of observed temperature rise for variation in altitude |
76 | 11.3 Impulse tests 11.3.1 Impulse test sequence 11.3.1.1 Wave to be used 11.3.1.2 Reduced full-wave test 11.3.1.3 Chopped-wave test 11.3.1.4 Full-wave test |
77 | 11.3.1.5 Current transformer connections for impulse test 11.3.1.6 Voltage transformer connections for impulse test 11.3.1.7 Detection of failure during impulse test |
78 | 11.4 Partial discharge measurement |
79 | 11.5 Wet voltage withstand tests 11.5.1 Switching impulse voltage test on the primary winding 11.5.2 Power frequency voltage withstand test |
80 | 11.6 Ground shield check—72kV class and above 12. Type test procedures applicable to current transformers 12.1 Short-time thermal rating of current transformers |
81 | 12.2 Current transformer temperature rise tests 12.3 Inter-turn overvoltage test |
82 | 13. Type test procedures applicable to voltage transformers 13.1 Short-circuit thermal capability of voltage transformers |
83 | 13.2 Voltage transformer temperature rise tests |
84 | Annex A (informative) Bibliography |
87 | Annex B (normative) Bushing-type current transformer (BCT) and special purpose window type current transformers B.1 Introduction B.2 Scope B.3 General requirements B.3.1 Accuracy ratings |
89 | B.4 Continuous thermal ratings B.4.1 Ambient temperature B.4.2 Insulation class B.4.3 Limits of temperature rise |
90 | B.4.4 Rating factor (RF) |
91 | B.5 Short-time ratings B.6 Dielectric consideration B.7 Construction B.7.1 Polarity |
92 | B.7.2 Secondary leads B.7.3 Winding and tap arrangements B.7.4 Finish |
93 | B.7.5 Nameplates B.8 Routine tests |
94 | B.9 Type tests B.10 Installation B.10.1 Installation of an external slip-over BCT |
95 | B.11 Field tests B.12 Bushing linear coupler (BLC) |
96 | Back cover |