New IEEE Standard – Active. Outdoor and indoor composite station post insulators used in high-voltage direct-current power transmission systems are covered in this standard. The composite station post insulators covered by this standard consist of a load-bearing insulating core (or tube), a housing (outside the insulating solid core or tube) made of elastomer material (e.g., silicone or ethylene-propylene), and end fittings attached to the insulating core (or tube).

PDF Catalog

PDF Pages PDF Title
1 IEEE Std 1898™-2016 Front cover
2 Title page
4 Important Notices and Disclaimers Concerning IEEE Standards Documents
7 Participants
8 Introduction
9 Contents
11 1. Scope
2. Normative references
12 3. Definitions
13 4. Environmental conditions
5. Environmental impact
6. Ratings
6.1 Mechanical loads
14 6.2 Insulation levels
6.3 Nominal creepage distance
7. Classification of tests
7.1 General
7.2 Design tests
7.3 Type tests
15 7.4 Sample tests
7.5 Routine tests
7.6 Special tests
8. Design tests
8.1 General
16 8.2 Tests on interfaces and connections of end fittings
8.3 Assembled core load tests
8.4 Tests on shed and housing material
20 8.5 General test on the core (or tube) material
21 9. Type tests
9.1 General
22 9.2 Verification of dimensions
9.3 Mechanical tests
23 9.4 Electrical tests
24 10. Sample tests
10.1 General
10.2 Verification of dimensions
10.3 Measurement of housing thickness
10.4 Galvanizing test
10.5 Temperature cycle test
25 10.6 Mechanical failing load test for C insulator
10.7 Porosity test
10.8 Mechanical tests for H insulator
10.9 Verification of specified mechanical loads for FR insulator
10.10 Test for the determination of the glass transition temperature by DSC method
11. Routine tests
11.1 General
11.2 Visual examination
11.3 Routine mechanical test
11.4 Routine tightness test
26 11.5 Routine pressure test
11.6 Ultrasonic test for C-insulator
12. Special tests
12.1 Artificial pollution test
27 Annex A (normative) Ultrasonic test for C-insulator
A.1 General
A.2 Test requirements
A.3 Standard artificial defect sample
28 A.4 Operating sensitivity of ultrasonic defect detector
29 A.5 Acceptance criteria
30 Annex B (informative) Inclined plane test method under dc voltage
31 Annex C (informative) Tracking and erosion test—Tracking wheel test
C.1 General
C.2 Test specimens
C.3 Procedure
C.4 Test conditions
32 C.5 Acceptance criteria
33 Annex D (informative) Test of transference of hydrophobicity
D.1 Method of hydrophobicity measurement
D.2 Test specimens
D.3 Test procedure
34 D.4 Acceptance criteria
35 Back cover
IEEE 1898 2016