Shopping Cart

No products in the cart.

BSI PD ISO/TS 14198:2019

$167.15

Road vehicles. Ergonomic aspects of transport information and control systems. Calibration tasks for methods which assess driver demand due to the use of in-vehicle systems

Published By Publication Date Number of Pages
BSI 2019 34
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This document provides procedures that can be used as a secondary task in a dual task setting to determine whether that evaluation setting is standardized and valid for purposes of assessing driver attentional demand due to the use of an in-vehicle system. This document does not define calibration procedures for other evaluation activities that a laboratory might undertake.

This document provides guidance on selecting a calibration task given a specific primary task. The primary tasks of interest include those that would be used in the evaluation of attentional demand. Such primary tasks are defined in other documents.

The description of a calibration task includes its application, experimental setup, data collection, and procedures for analysis of results.

The purpose of this document is not to define a reference criterion as to whether a given secondary task is suitable for use while driving. Although specific settings of parameters of a calibration task might be used to realize such a predefined pass/fail criterion, this document does not provide such a criterion for a given level of attentional demand.

PDF Catalog

PDF Pages PDF Title
2 undefined
6 Foreword
7 Introduction
9 1 Scope
2 Normative references
3 Terms and definitions
11 4 Abbreviated terms
12 5 Calibration tasks
5.1 Principle and overview
5.2 Types of calibration tasks
5.3 Critical Tracking Task (CTT)
5.3.1 Description
13 5.3.2 Operation of the CTT
14 5.3.3 Setup for CTT
5.3.4 Test conditions for CTT
5.3.5 Participants for CTT
5.3.6 Participant instruction for CTT
15 5.3.7 Practice trials
5.3.8 Test metrics
5.4 Surrogate Reference Task (SURT)
5.4.1 Description
16 5.4.2 Setup for SURT
17 5.4.3 Test conditions for SURT
5.4.4 Participants for SURT
5.4.5 Participant instructions for SURT
18 5.4.6 Practice trials
5.4.7 Test metrics
5.5 N-back
5.5.1 Description
5.5.2 Operation of the n-back
19 5.5.3 Setup for n-back
5.5.4 Test conditions for n-back
5.5.5 Participants for n-back
5.5.6 Participant instruction for n-back
20 5.5.7 Practice trials
5.5.8 Test metrics
6 Calibration criterion
6.1 Calibration criterion procedure
22 6.2 General calibration considerations
23 Annex A (informative) Calibration task setup details using the LCT
25 Annex B (informative) Multi-lab reference data for LCT
27 Annex C (informative) Calibration task setup details using the DRT
28 Annex D (informative) Multi-lab reference data for DRT
30 Bibliography
BSI PD ISO/TS 14198:2019
$167.15