BSI PD IEC/TR 60601-4-2:2016

$198.66

Medical electrical equipment – Guidance and interpretation. Electromagnetic immunity: performance of medical electrical equipment and medical electrical systems

Published By Publication Date Number of Pages
BSI 2016 62
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. Weā€™re here to assist you 24/7.
Email:[email protected]

IEC TR 60601-4-2:2016(E) applies to the performance of medical electrical equipment or a medical electrical system in the presence of electromagnetic disturbances.

PDF Catalog

PDF Pages PDF Title
4 CONTENTS
7 FOREWORD
10 INTRODUCTION
0.1 * General
0.2 Purpose of this document
0.3 How to use this document
11 0.4 Immunity test levels
12 1 Scope and object
1.1 Scope
1.2 Object
2 Normative references
13 3 Terms and definitions
17 4 General recommendations
4.1 Concurrent and sequential testing
4.2 General test conditions
4.2.1 Configurations
4.2.2 Artificial hand
18 4.2.3 Power input voltages and frequencies
Figures
FigureĀ 1Ā ā€“ RC element of the artificial hand
19 5 Me equipment and me systems identification, marking and documents
5.1 Marking on the outside of me equipment or me equipment parts for which the connector testing exemption specified in 8.13.2 d) is used
5.2 Accompanying documents
5.2.1 General
5.2.2 Instructions for use
5.2.3 Requirements applicable to me equipment and me systems for which the connector testing exemption specified in 8.13.2 d) is used
5.2.4 * Technical description
20 6 Documentation of the tests
6.1 Test plan
Tables
TableĀ 1Ā ā€“ Recommended minimum test plan (1 of 2)
21 6.2 Test report
7 * Emissions
8 Immunity recommendations
8.1 General
22 8.2 Patient physiological simulation
FigureĀ 2Ā ā€“ *Ā Ports of me equipment and me systems
23 8.3 Termination of patient-coupled parts
8.4 Hand-held me equipment and parts intended to be hand-held
8.5 Subsystems
8.6 Permanently installed large me equipment and large me systems
24 8.7 Operating modes
8.8 Non-me equipment
8.9 * Environments of intended use
25 8.10 * Performance criteria
8.11 * Immunity test levels
27 FigureĀ 3Ā ā€“ Examples of environments (locations) of intended use
28 TableĀ 2Ā ā€“ *Ā Enclosure port
TableĀ 3Ā ā€“ *Ā Input AC power port (1 of 2)
30 TableĀ 4Ā ā€“ Input DC power port
31 TableĀ 5Ā ā€“ *Ā Patient coupling port
32 8.12 * Immunity to proximity fields from RF wireless communications equipment
TableĀ 6Ā ā€“ Signal input/output parts port
33 8.13 * ESD testing of connectors
8.13.1 Application of ESD to connectors
TableĀ 7Ā ā€“ Test specifications for enclosure port immunity to RF wireless communications equipment
34 8.13.2 Exclusions
Table 8 ā€“ Parts of connectors to be tested for ESD, based on the connector shell and cover material
TableĀ 9Ā ā€“ *Ā Testing of connectors and pins while connected and disconnected
35 9 Test report
TableĀ 10Ā ā€“ Test report minimum contents (1 of 2)
37 Annexes
Annex A (informative) General guidance and rationale
40 TableĀ A.1Ā ā€“ Assumptions used in determining immunity test levelsspecified in TableĀ 7 (1 of 2)
42 Annex B (informative) Guide to labelling recommendations
B.1 Accompanying documents, instructions for use
B.2 Accompanying documents, technical description
TableĀ B.1 ā€“ accompanying documents, instructions for use
TableĀ B.2 ā€“ Accompanying documents, technical description
43 Annex C (informative) Determination of immunity test levels for special environments
C.1 General
44 C.2 em disturbance level determination
C.3 Assessment of em disturbance sources
C.4 Test methods
C.5 Test plan
45 C.6 Examples of mitigations and special conditions
TableĀ C.1Ā ā€“ Examples of adjusted immunity test levels due to mitigations or special conditions
46 Annex D (informative) Identification of specific immunity performance criteria
D.1 General
D.2 Immunity performance criteria principles
D.2.1 General
D.2.2 Immunity performance criteria for non-me equipment used in an me system
D.2.3 Immunity performance criteria determination
D.3 Immunity performance criteria examples
D.3.1 General examples
48 D.3.2 Example of immunity performance criteria for a radiological table system
D.3.3 Example of immunity performance criteria for ultrasonic diagnostic equipment
Table D.1 ā€“ Example of immunity performance criteria for a radiological table and gantry system
49 Table D.2 ā€“ Example of immunity performance criteria for ultrasonic diagnostic equipment
50 Annex E (informative) Performance criteria specified by IEC 61000-6-x generic EMC standards
51 Annex F (informative) Mapping between this document and the elements of IEC 60601-1-2:2014
TableĀ F.1Ā ā€“ Mapping between the elements of IECĀ TR 60601-4-2 andIECĀ 60601-1-2:2014 (1 of 5)
56 Bibliography
58 Index of defined terms used in this technical report
BSI PD IEC/TR 60601-4-2:2016