Shopping Cart

No products in the cart.

BSI PD IEC/PAS 62958:2015

$167.15

Clothes washing machines for household use. Method for measuring the microbial contamination reduction

Published By Publication Date Number of Pages
BSI 2015 34
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This Publicly Available Specification (PAS) specifies a test method for measuring the reduction of microbial contamination in clothes washing machines and of the possible cross contamination to uncontaminated load.

NOTE A significant differentiation in microorganism contamination reduction capability of washing machines can be expected at wash temperature not higher than 40 °C.

This PAS applies to clothes washing machines for household use, with or without heating devices utilising cold and/or hot water supply. It also covers washing machines which specify the use of no detergent for normal use. This PAS applies also to washing machines for communal use in blocks of flats or in launderettes.

This PAS does not deal with professional washing machines nor with commercial laundry operations associated with food service, hospital linens or other non-residential applications. It also does not address the needs of persons with specific health conditions requiring special sanitization and/or disinfection techniques.

This PAS does not specify safety requirements and does not deal with performance of washing machines measured under IEC 60456 nor with effects on fabrics.

PDF Catalog

PDF Pages PDF Title
4 CONTENTS
7 FOREWORD
9 INTRODUCTION
10 1 Scope
2 Normative references
11 3 Terms, definitions and symbols
3.1 Terms and definitions
3.2 Symbols
12 4 Requirements
5 Test conditions, materials, equipment and instrumentation
5.1 Test conditions
5.2 Materials and reagents
5.2.1 Microorganisms for test purposes
5.2.2 Culture media and solutions
13 Tables
Table 1 – Composition of Tryptone Soy Agar (TSA)
Table 2 – Composition of Sabouraud Dextrose Agar with Chloramphenicol
Table 3 – Composition of Cetrimide Agar
14 Table 4 – Composition of Baird-Parker Agar
Table 5 – Composition of Malt Extract Agar (MEA)
Table 6 – Composition of Tryptone Soy Broth (TSB)
15 5.2.3 Detergent
Table 7 – Composition of diluting agent
Table 8 – Composition of recommended neutralisation solution
16 5.3 Equipment
5.3.1 General
5.3.2 Incubator
5.3.3 Autoclave
5.3.4 Microorganism carrier
5.3.5 Pipettes
5.3.6 Electromechanical agitator
5.3.7 Centrifuge, centrifuge tubes
5.3.8 Base load
17 5.3.9 Measuring equipment for assessing temperature profile
5.3.10 Measuring equipment for water consumption
6 Tests
6.1 Test method principles
6.2 Preparation of test washing machine
6.3 Preparation of test microorganisms and bio monitors
6.3.1 Cultures
Table 9 – Specifications for temperature logger
19 6.3.2 Bio monitors
20 6.4 Main test
6.4.1 General
6.4.2 Evidence of test microorganisms
6.5 Validation
6.5.1 Enumeration of microorganisms before exposition N0 (bio monitor reference)
6.5.2 Negative control (cross contamination)
21 6.5.3 Determination of water quality
6.5.4 Determination of water quantity in the main wash
7 Evaluation
7.1 Log reduction
7.2 Cross contamination
8 Test report
23 Annex A (informative) Microorganism reduction in household washing machines with risk class 1 test microorganisms for internal development purpose
A.1 Scope
A.2 General recommendation
A.3 Material and reagents
A.3.1 Microorganisms on bio monitors
A.3.2 Water for culture media and solutions
A.3.3 Culture media and solutions
24 Table A.1 – Composition of Sabouraud Dextrose Agar
Table A.2 – Composition of Columbia CNA Agar
25 A.3.4 Detergent
A.4 Equipment
A.4.1 Incubator
A.4.2 Autoclave
A.4.3 Microorganism carrier
A.4.4 Pipettes
A.4.5 Electromechanical agitator
A.4.6 Centrifuge
A.4.7 Base load
A.4.8 Measuring equipment for assessing temperature profile
A.4.9 Measuring equipment for water consumption
A.5 Tests
A.5.1 Test method principles
26 A.5.2 Preparation of washing machine
A.5.3 Preparation of test organisms and bio monitors
27 A.5.4 Main test
Figures
Figure A.1 – Scheme for preparing a dilution series
28 A.5.5 Validation
A.6 Evaluation
A.6.1 Plate counts per bio monitor
29 A.6.2 Log reductions
A.6.3 Cross contamination
A.7 Test report
30 Annex B (informative) Sources of materials and supplies
B.1 Disclaimer
B.2 Microorganism carriers
B.3 Electromechanical agitator
B.4 Ready-to-use bio monitors
B.5 Nonionic surfactant and emulsifier
31 Bibliography
BSI PD IEC/PAS 62958:2015