BSI PD CEN/TS 16794-1:2015
$167.15
Public transport. Communication between contactless readers and fare media – Implementation requirements for ISO/IEC 14443
Published By | Publication Date | Number of Pages |
BSI | 2015 | 34 |
This Technical Specification sets out the technical requirements to be met by contactless fare management system terminals and contactless fare media hosting a transport ticketing application in order to be able to interface together using the ISO/IEC 14443 standard contactless communications protocol.
This Technical Specification applies to:
-
any contactless fare management system terminal acting as a PCD contactless reader based on ISO/IEC 14443 standard series;
-
any contactless fare media acting as a PICC contactless object based on ISO/IEC 14443 standard series.
The purpose of these implementation requirements is to ensure contactless communications interoperability between contactless fare management system terminals and any contactless fare media liable to be accepted by them, once both terminal and fare media have been certified as meeting the requirements of these implementation requirements. An interface–oriented test approach will be used to evaluate the interoperability of relevant components and is defined in CEN/TS 16794‑2 , Public transport — Communication between contactless readers and fare media — Part 2: Test plan for ISO/IEC 14443 .
Application-to-application exchanges executed once contactless communication has been established at RF level fall outside the scope of these implementation requirements. In line with the rules on independency between OSI protocol layers, these implementation requirements work on the assumption that application-to-application exchanges are not contingent on the type of contactless communication established or by the parameters used for the low-level protocol layers that serve as the platform for these application-to-application exchanges.
PDF Catalog
PDF Pages | PDF Title |
---|---|
5 | Foreword |
6 | Introduction |
7 | 1 Scope 2 Normative references |
9 | 3 Terms and definitions 4 Symbols and abbreviations |
10 | 5 Conformance 6 General considerations for fare media and contactless readers 6.1 Combining the present requirements with others industry standards |
11 | 6.2 Progressive and flexible approach to the targeted interoperability 7 Requirements on contactless readers 7.1 General |
12 | 7.2 Categories for contactless reader 7.3 Normative requirements for contactless readers |
13 | 7.4 Specific requirements for contactless readers 7.5 Requirements on polling and recognizing contactless objects |
15 | 7.6 Performance requirements (informative) 8 Requirements on contactless objects 8.1 General 8.2 Normative requirements for contactless objects 8.3 Specific requirements for contactless objects |
16 | 8.4 Requirements concerning field ramp-ups and shut-offs 8.5 Performance requirements (informative) 9 Test boundaries and test conditions 9.1 Implementation characteristics 9.1.1 General |
17 | 9.1.2 ICS for contactless readers – PCD |
18 | 9.1.3 ICS for contactless objects – PICC |
20 | 9.2 Test conditions 9.2.1 General 9.2.2 Temperature Table 1 — Temperature ranges for contactless readers and contactless objects |
21 | 9.2.3 Test positions for contactless readers 9.2.3.1 General Figure 1 —Example of a contactless reader with different A and B ranges 9.2.3.2 Operating distance – Range A |
22 | Figure 2 — Testing a flat-surface reader Figure 3 — Testing a flat and tilted-surface reader |
23 | Figure 4 — Testing a convex-surface reader Figure 5 — Testing a concave-surface contactless reader with a high-raised PCD Zero Point 9.2.3.3 Table of positions – Range A Table 2 — List of test positions for range A |
24 | Figure 6 — Example 1: Reference PICC in Position A5 Figure 7 — Example 2: Reference PICC in Position A1′ 9.2.3.4 Operating distance – Range B |
25 | 9.2.3.5 Table of positions – Range B Table 3 — List of test positions for range B |
26 | Figure 8 — Example 1: Reference PICC in Position B3 Figure 9 — Example 2: Reference PICC in Position B1′ 9.2.4 Test positions for contactless object |
27 | Figure 10 — Positioning for flat-surfaced contactless object under test Figure 11 — Positioning for non-flat-surfaced contactless object under test |
28 | Figure 12 — Positioning for contactless object under test — overhead view 9.2.5 Battery-powered contactless object 9.2.6 Test mode for contactless readers |
29 | 9.2.7 Test application for contactless object |
30 | Annex A (informative) Examples of PICC polling scenarios A.1 Examples of generic polling scenarios A.1.1 Without shut-off of the operational field A.1.1.1 General Figure A.1 Figure A.2 Figure A.3 |
31 | A.1.2 With shut-off of the operational field Figure A.4 Figure A.5 A.2 Examples of specific polling scenarios A.2.1 General A.2.2 Treating the first of all the objects detected A.2.3 Treating one contactless object identified from many after completion of the polling sequence |