BSI 23/30465156 DC:2023 Edition
$13.70
BS EN IEC 61076-2-117. Connectors for electrical and electronic equipment. Detail specification for shielded, free and fixed circular connectors M12 to M40 for power, signal and data transmission with frequencies up to 600 MHz
Published By | Publication Date | Number of Pages |
BSI | 2023 | 85 |
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | 30465156-NC.pdf |
3 | 48B_3046e_CD.pdf |
10 | FOREWORD |
13 | 1 Scope 2 Normative references |
15 | 3 Terms and definitions 4 Technical information 4.1 Systems of levels – Compatibility levels, according to IEC 61076-1 4.1.1 Performance level 4.1.2 Compatibility levels according to IEC 61076 |
16 | 4.2 Classification into climatic categories 4.3 Clearance and creepage distances 4.4 Current carrying capacity 4.5 Marking 4.6 Safety aspects 5 Dimensional information 5.1 General |
17 | 5.2 Coding |
20 | 5.3 Interface dimensions 5.3.1 M12 |
25 | 5.3.2 M17 |
28 | 5.3.3 M23 |
33 | 5.3.4 M40 |
36 | 5.4 Survey of styles and variants 5.4.1 Fixed connectors |
37 | 5.4.1.1 Styles Mxx_DM and Mxx_DF |
38 | 5.4.1.2 Styles Mxx_EM, Mxx_EF, Mxx_GM and Mxx_GF |
39 | 5.4.1.3 Styles Mxx_DM90 and Mxx_DF90 |
40 | 5.4.1.4 Styles Mxx_EM90 and Mxx_EF90 5.4.2 Free connectors |
41 | 5.4.2.1 Styles Mxx_JM, Mxx_JF |
42 | 5.4.2.2 Styles Mxx_LM and Mxx_LF 5.4.2.3 Styles Mxx_JMC and Mxx_JFC |
43 | 5.4.2.4 Styles Mxx_LMC and Mxx_LFC |
44 | 5.5 Engagement (mating) information 5.5.1 Engagement (mating) direction |
48 | 5.6 Gauges |
49 | 6 Characteristics 6.1 General 6.2 Pin assignment |
55 | 6.3 Classification into climatic category 6.4 Electrical characteristics 6.4.1 Voltage information for Creepage and clearance distances |
56 | 6.4.2 Voltage proof |
57 | 6.4.3 Current-temperature derating 6.4.4 Current rating |
58 | 6.4.5 Contact resistance – interface only (separable fixed and free contact) 6.4.6 Input to output d.c. resistance 6.4.7 Input to output d.c. resistance unbalanced |
59 | 6.4.8 Insulation resistance 6.4.9 Impedance 6.5 Transmission performance 6.5.1 General 6.5.2 Insertion loss |
61 | 6.5.3 Return loss |
62 | 6.5.4 Near-end cross talk (NEXT) |
63 | 6.5.5 Far-end cross talk (FEXT) |
64 | 6.5.6 Transverse conversion loss (TCL) |
65 | 6.5.7 Transverse conversion transfer loss (TCTL) |
66 | 6.5.8 Transfer impedance |
67 | 6.5.9 Coupling attenuation |
68 | 6.5.10 Power sum alien (exogenous) NEXT (PS ANEXT) |
69 | 6.5.11 Power sum alien (exogenous) FEXT (PS AFEXT) |
70 | 6.5.12 Propagation delay 6.6 Mechanical characteristics 6.6.1 IP degree of protection 6.6.2 Mechanical operation |
71 | 6.6.3 Effectiveness of connector coupling devices 6.6.4 Insertion and withdrawal forces |
72 | 6.6.5 Polarizing method 6.6.6 Vibration (sinusoidal) 6.6.7 Shock 7 Tests and test schedule 7.1 General |
73 | 7.2 Mounting of specimens 7.2.1 General |
74 | 7.2.2 Arrangement for contact resistance measurement 7.2.3 Arrangement for dynamic stress tests |
76 | 7.2.4 Wiring of specimens 7.3 Test procedures and measuring methods 7.4 Preconditioning 7.5 Test schedules 7.5.1 General 7.5.2 Basic (minimum) test schedule 7.5.3 Full test schedule 7.5.3.1 General 7.5.3.2 Test group P – Preliminary |
78 | 7.5.4 Test group AP – Dynamic/Climatic |
81 | 7.5.5 Test group BP – Mechanical endurance |
82 | 7.5.6 Test group CP – Electrical load |
83 | 7.5.7 Test group DP – Chemical resistivity 7.5.8 Test group EP – Connection method tests |
84 | 7.5.9 Test group FP – Electrical transmission |
85 | 7.5.10 Test group GP – Transfer Impedance and Coupling Attenuation |