BS EN 15012. Plastics piping systems. Buried and above ground piping components for non pressure soil and waste discharge within the building structure. Requirements and test/assessment methods for pipes and fittings
Published By | Publication Date | Number of Pages |
BSI | 2014 | 61 |
PDF Catalog
PDF Pages | PDF Title |
---|---|
4 | Contents Page |
5 | Foreword |
6 | Introduction |
7 | 1 Scope 2 Normative references |
9 | 3 Terms, definitions and abbreviations 3.1 Terms and definitions |
10 | 3.2 Abbreviations 4 Product characteristics 4.1 Reaction to fire of pipes and fittings 4.2 Maximum load for admissible deformation of pipes and fittings (only relevant for buried in ground applications) 4.2.1 General |
11 | 4.2.2 Ring stiffness of pipes 4.2.3 Ring stiffness of fittings 4.3 Dimensional tolerances of pipes and fittings 4.4 Tightness: Gas and liquid 4.4.1 General 4.4.2 Tightness of pipes and fittings intended for application inside buildings |
12 | 4.4.3 Tightness of pipes and fittings intended for application buried in ground within the building structure 4.5 Release of dangerous substances of pipes and fittings 4.6 Durability 4.6.1 General 4.6.2 Durability of tightness of pipes and fittings intended for application inside buildings 4.6.3 Durability of tightness of pipes and fittings intended for application buried in ground within the building structure |
13 | 5 Test methods 5.1 Reaction to fire of pipes and fittings 5.2 Maximum load for admissible deformation (only relevant for buried in ground applications) 5.2.1 Ring stiffness of thermoplastics pipes 5.2.2 Ring stiffness of thermoplastics fittings 5.3 Dimensional tolerances |
15 | 5.4 Tightness: Gas and liquid 5.4.1 General |
16 | 5.4.2 Tightness of pipes and fittings intended for application inside buildings 5.4.3 Tightness of pipes and fittings intended for application buried in ground within the building structure |
17 | 5.5 Release of dangerous substances of pipes and fittings 5.6 Durability 5.6.1 General 5.6.2 Durability of tightness of pipes and fittings intended for application inside buildings 5.6.2.1 Material properties for applications inside buildings |
18 | 5.6.2.2 Resistance to temperature cycling test of pipes and fittings |
19 | 5.6.3 Durability of tightness of pipes and fittings intended for application buried in ground within the building structure 5.6.3.1 Material properties for application buried in ground within the building structure |
20 | 5.6.3.2 Resistance to temperature cycling test of pipes and fittings 6 Assessment and verification of the constancy of performance (AVCP) 6.1 General 6.2 Type testing 6.2.1 General |
22 | 6.2.2 Test samples, testing and compliance criteria |
31 | 6.2.3 Test reports 6.3 Factory production control (FPC) 6.3.1 General |
32 | 6.3.2 Requirements 6.3.2.1 General |
33 | 6.3.2.2 Equipment 6.3.2.3 Raw materials and components 6.3.2.4 Traceability and marking 6.3.2.5 Controls during manufacturing process 6.3.2.6 Product testing and evaluation |
44 | 6.3.2.7 Non-complying products 6.3.2.8 Corrective action |
45 | 6.3.2.9 Handling, storage and packaging 6.3.3 Product specific requirements 6.3.4 Initial inspection of factory and of FPC (only for products covered by AVCP system 1 for reaction to fire) |
46 | 6.3.5 Continuous surveillance of FPC (only for reaction to fire under AVCP system 1) 6.3.6 Procedure for modifications 6.3.7 One-off products, pre-production products (e.g. prototypes) and products produced in very low quantity |
48 | Annex ZA (informative)Clauses of this European Standard addressing the provisionsof EU Construction Products Regulation |
61 | Bibliography |