BS ISO 13253:2017+A1:2020
$215.11
Ducted air-conditioners and air-to-air heat pumps. Testing and rating for performance
Published By | Publication Date | Number of Pages |
BSI | 2020 | 98 |
This document specifies performance testing, the standard conditions and the test methods for determining the capacity and efficiency ratings of air-cooled, air-conditioners and air-to-air heat pumps.
This document is applicable to the following equipment:
-
ducted air-cooled air conditioners and ducted air to air heat pumps.
This document is limited to
-
residential, commercial and industrial single-package, and split-system air conditioners and heat pumps,
-
factory-made, electrically driven and use mechanical compression,
-
utilizing single, multiple and variable capacity components, and
-
multiple split-system utilizing one or more refrigeration systems, one outdoor unit and one or more indoor units, controlled by a single thermostat/controller.
The requirements of testing and rating contained in this document are based on the use of matched assemblies.
This document is not applicable to the rating and testing of the following:
-
water-source heat pumps or water-cooled air-conditioners;
-
multi-split-system air-conditioners and air-to-air heat pumps (see ISO 15042 for testing of such equipment);
-
mobile (windowless) units having a condenser exhaust duct;
-
individual assemblies not constituting a complete refrigeration system;
-
equipment using the absorption refrigeration cycle;
-
non-ducted equipment (see ISO 5151 for testing of such equipment);
-
ducted air conditioners and/or ducted heat pumps, rated at less than 8 kW and intended to operate at external static pressures of less than 25 Pa, controlled by a single thermostat/controller (refer to ISO 5151 ).
This document does not cover the determination of seasonal efficiencies, which can be required in some countries because they provide a better indication of efficiency under actual operating conditions.
NOTE Throughout this document, the terms “equipment” and “systems” mean “air-conditioners” and/or “heat pumps”.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
8 | Foreword |
9 | 1 Scope 2 Normative references |
10 | 3 Terms and definitions |
12 | 4 Symbols |
15 | 5 Airflow setting 5.1 General 5.2 Indoor airflow setting 5.3 ESP for rating |
17 | 5.4 Outdoor airflow 5.5 Unit supplied without indoor fan 6 Cooling tests 6.1 Cooling capacity tests 6.1.1 General conditions |
18 | 6.1.2 Temperature conditions |
19 | 6.1.3 Test conditions 6.2 Maximum cooling performance test 6.2.1 General conditions 6.2.2 Temperature conditions |
20 | 6.2.3 Airflow conditions 6.2.4 Test conditions 6.2.5 Performance requirements |
21 | 6.3 Minimum cooling performance test 6.3.1 General conditions 6.3.2 Temperature conditions 6.3.3 Airflow conditions |
22 | 6.3.4 Test conditions 6.3.5 Performance requirements |
23 | 6.4 Condensate control and enclosure sweat performance test 6.4.1 General conditions 6.4.2 Temperature conditions 6.4.3 Airflow conditions 6.4.4 Test conditions 6.4.5 Performance requirements |
24 | 7 Heating tests 7.1 Heating capacity tests 7.1.1 General conditions |
25 | 7.1.2 Temperature conditions 7.1.3 Airflow conditions |
26 | 7.1.4 Defrost operation 7.1.5 Test procedure — General |
27 | 7.1.6 Preconditioning period 7.1.7 Equilibrium period 7.1.8 Data collection period |
28 | 7.1.9 Test procedure when a defrost cycle (whether automatically or manually initiated) ends the preconditioning period 7.1.10 Test procedure when a defrost cycle does not end the preconditioning period 7.1.11 Test procedure for transient tests |
30 | 7.1.12 Heating capacity test results 7.2 Maximum heating performance test 7.2.1 General conditions 7.2.2 Temperature conditions 7.2.3 Airflow conditions |
31 | 7.2.4 Test conditions 7.2.5 Performance requirements 7.3 Minimum heating performance test 7.3.1 General conditions 7.3.2 Temperature conditions 7.3.3 Airflow conditions 7.3.4 Test conditions |
32 | 7.3.5 Performance requirements 7.4 Automatic defrost performance test 7.4.1 General conditions 7.4.2 Temperature conditions 7.4.3 Airflow conditions 7.4.4 Test conditions |
33 | 7.4.5 Performance requirements 8 Test methods and uncertainties of measurement 8.1 Test methods 8.1.1 General 8.1.2 Calorimeter test method 8.1.3 Indoor air enthalpy method |
34 | 8.1.4 Capacity tests 8.2 Uncertainty of measurement |
35 | 8.3 Test tolerances for steady-state cooling and heating capacity tests |
36 | 8.4 Test tolerances for performance tests 9 Test results 9.1 Capacity results 9.1.1 General |
37 | 9.1.2 Adjustments 9.1.3 Cooling capacity calculations 9.1.4 Heating capacity calculations |
38 | 9.2 Data to be recorded |
41 | 9.3 Test report 9.3.1 General information 9.3.2 Capacity test results 9.3.3 Performance tests |
42 | 10 Marking provisions 10.1 Nameplate requirements 10.2 Nameplate information 10.3 Split systems 11 Publication of ratings 11.1 Standard ratings |
43 | 11.2 Other ratings |
44 | Annex A (normative) Airflow settings for ducted units |
49 | Annex B (normative) Test requirements |
56 | Annex C (informative) Airflow measurement |
62 | Annex D (normative) Calorimeter test method |
70 | Annex E (normative) Indoor air enthalpy test method |
76 | Annex F (informative) Refrigerant enthalpy test method |
78 | Annex G (informative) Outdoor air enthalpy test method |
81 | Annex H (informative) Indoor calorimeter confirmative test method |
83 | Annex I (informative) Outdoor calorimeter confirmative test method |
85 | Annex J (informative) Balanced-type calorimeter confirmative test method |
86 | Annex K (informative) Cooling condensate measurements |
87 | Annex L (normative) Supplemental requirements when rating fan-less (coil-only) type units |
90 | Annex M (informative) Pictorial examples of the heating capacity test procedures given in 7.1 |
97 | Bibliography |