BS EN ISO 16890-2:2022
$215.11
Air filters for general ventilation – Measurement of fractional efficiency and air flow resistance
Published By | Publication Date | Number of Pages |
BSI | 2022 | 76 |
This document specifies the aerosol production, the test equipment and the test methods used for measuring fractional efficiency and air flow resistance of air filters for general ventilation. It is intended to be used in conjunction with ISO 16890?1, ISO 16890?3 and ISO 16890?4. The test method described in this document is applicable for air flow rates between 0,25 m3/s (900 m3/h, 530 ft3/min) and 1,5 m3/s (5 400 m3/h, 3 178 ft3/min), referring to a test rig with a nominal face area of 610 mm × 610 mm (24.0 inches × 24.0 inches). This document refers to particulate air filter elements for general ventilation having an ePM1 efficiency less than or equal to 99 % and an ePM10 efficiency greater than 20 % when tested as per the procedures defined within the ISO 16890 series. NOTE The lower limit for this test procedure is set at a minimum ePM10 efficiency of 20 % since it is very difficult for a test filter element below this level to meet the statistical validity requirements of this procedure. This document is not applicable to filter elements used in portable room-air cleaners.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
5 | European foreword Endorsement notice |
11 | Foreword |
13 | Introduction |
16 | 1 Scope 2 Normative references 3 Terms and definitions |
17 | 3.1 Air flow and resistance 3.2 Test device 3.3 Aerosol |
18 | 3.4 Particle counter 3.5 Efficiency |
19 | 3.6 Other terms 4 Symbols and abbreviated terms 4.1 Symbols |
21 | 4.2 Abbreviated terms 5 General test requirements 5.1 Test device requirements 5.2 Test device installation |
22 | 5.3 Test rig requirements 6 Test materials 6.1 Liquid phase aerosol 6.1.1 DiEthylHexylSebacate (DEHS) test aerosol 6.1.2 DEHS properties 6.1.3 Liquid phase aerosol generation |
23 | 6.2 Solid phase aerosol 6.2.1 Potassium chloride (KCl) test aerosol 6.2.2 KCl properties |
24 | 6.2.3 Solid phase aerosol generation |
25 | 6.3 Reference aerosols 6.3.1 Reference aerosol for 0,3 µm to 1,0 µm 6.3.2 Reference aerosol for 1,0 µm to 10,0 µm 6.4 Aerosol loading |
26 | 7 Test equipment 7.1 Test rig 7.1.1 Dimensions 7.1.2 Construction materials |
27 | 7.1.3 Test rig shape 7.1.4 Test rig air supply 7.1.5 Test rig isolation 7.1.6 D/S mixing orifice |
28 | 7.1.7 Aerosol sampling |
30 | 7.1.8 Test rig air flow rate measurement 7.1.9 Resistance to air flow measurement |
31 | 7.1.10 Test devices not measuring 610 mm × 610 mm (24.0 inches × 24.0 inches) 7.1.11 Dust injection testing |
32 | 7.2 Aerosol particle counter 7.2.1 General 7.2.2 OPC sampled size range 7.2.3 OPC particle size ranges |
33 | 7.2.4 Sizing resolution 7.2.5 Calibration 7.2.6 Air flow rate 7.2.7 Zero counting 7.2.8 Dual OPC(s) 7.3 Temperature, relative humidity |
34 | 8 Qualification of test rig and apparatus 8.1 Schedule of qualification testing requirements 8.1.1 General 8.1.2 Qualification testing 8.1.3 Qualification documentation |
35 | 8.2 Qualification testing 8.2.1 Test rig — Pressure system testing |
36 | 8.2.2 OPC — Air flow rate stability test 8.2.3 OPC — Zero test 8.2.4 OPC — Sizing accuracy |
37 | 8.2.5 OPC — Overload test 8.2.6 Aerosol generator — Response time |
38 | 8.2.7 Aerosol generator — Neutralizer |
39 | 8.2.8 Test rig — Air leakage test 8.2.9 Test rig — Air velocity uniformity |
40 | 8.2.10 Test rig — Aerosol uniformity |
41 | 8.2.11 Test rig — Downstream mixing |
43 | 8.2.12 Test rig — Empty test device section pressure 8.2.13 Test rig — 100 % efficiency test and purge time |
44 | 8.2.14 Test rig — Correlation ratio 8.3 Maintenance 8.3.1 General |
45 | 8.3.2 Test rig — Background counts 8.3.3 Test rig — Reference filter test |
46 | 8.3.4 Test rig — Pressure reference test |
47 | 8.3.5 Test rig — Final filter resistance 9 Test methods 9.1 Air flow rate 9.2 Measurement of resistance to air flow 9.3 Measurement of fractional efficiency 9.3.1 Aerosol sampling protocol 9.3.2 Background sampling |
48 | 9.3.3 Testing sequence for a single OPC |
52 | 9.3.4 Testing sequence for dual OPC |
53 | 10 Data reduction and calculations 10.1 Correlation ratio 10.1.1 Correlation ratio general |
54 | 10.1.2 Correlation ratio data reduction |
55 | 10.2 Penetration and fractional efficiency 10.2.1 Penetration and fractional efficiency general |
56 | 10.2.2 Penetration data reduction |
58 | 10.3 Data quality requirements 10.3.1 Correlation background counts 10.3.2 Efficiency background counts 10.3.3 Correlation ratio |
59 | 10.3.4 Penetration |
60 | 10.4 Fractional efficiency calculation 11 Reporting results 11.1 General 11.2 Required reporting elements 11.2.1 Report general 11.2.2 Report values |
61 | 11.2.3 Report summary |
62 | 11.2.4 Report details |
65 | Annex A (informative) Example |
72 | Annex B (informative) Resistance to air flow calculation |
74 | Bibliography |