Shopping Cart

No products in the cart.

BS EN IEC 62386-305:2023

$142.49

Digital addressable lighting interface – Particular requirements. Input devices. Colour sensor

Published By Publication Date Number of Pages
BSI 2023 28
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

PDF Catalog

PDF Pages PDF Title
2 undefined
5 Annex ZA (normative)Normative references to international publicationswith their corresponding European publications
6 English
CONTENTS
8 FOREWORD
10 INTRODUCTION
Figure 1 – IEC 62386 graphical overview
12 1 Scope
2 Normative references
3 Terms and definitions
13 4 General
4.1 General requirements
4.2 Version number
4.3 Insulation
5 Electrical specification
6 Bus power supply
7 Transmission protocol structure
8 Timing
9 Method of operation
9.1 General
9.2 Instance type
14 9.3 Input signal and value
9.3.1 General
9.3.2 Input value encoding
9.4 Events
9.4.1 Priority use
9.4.2 Bus usage
9.4.3 Encoding
Tables
Table 1 – Input value encoding
15 9.4.4 Event configuration
Table 2 – Colour value events
Table 3 – Colour report
Table 4 – Event filter
16 9.4.5 Event generation
9.5 Configuring the input device
9.5.1 Using the report timer
17 9.5.2 Using the deadtime timer
9.5.3 Setting the timers
Table 5 – Event timer setting
18 9.5.4 Setting the hysteresis
9.5.5 Manual configuration
9.6 Exception handling
9.6.1 Physical sensor failure
9.6.2 Manufacturer-specific errors
Table 6 – “manualCapabilityInstance3xx” values
19 9.6.3 Error value
10 Declaration of variables
Table 7 – “instanceErrorByte” values
Table 8 – Declaration of device variables
20 11 Definition of commands
11.1 General
11.2 Overview sheets
11.2.1 General
Table 9 – Restrictions to instance variables defined in IEC 62386-103:2022
Table 10 – Declaration of instance variables
21 11.2.2 Standard commands
11.3 Event messages
11.3.1 INPUT NOTIFICATION (device/instance, event)
11.3.2 POWER NOTIFICATION (device)
11.4 Device control instructions
11.5 Device configuration instructions
11.6 Device queries
11.7 Instance control instructions
11.8 Instance configuration instructions
11.8.1 General
Table 11 – Standard commands
22 11.8.2 SET EVENT FILTER (DTR0)
11.8.3 SET REPORT TIMER (DTR0)
11.8.4 SET HYSTERESIS (DTR0)
11.8.5 SET DEADTIME TIMER (DTR0)
11.8.6 SET HYSTERESIS MIN (DTR0)
11.9 Instance queries
11.9.1 General
11.9.2 QUERY COLOUR SENSOR (DTR0)
23 11.9.3 QUERY DEADTIME TIMER
11.9.4 QUERY INSTANCE ERROR
11.9.5 QUERY REPORT TIMER
Table 12 – DTR reference
24 11.9.6 QUERY HYSTERESIS
11.9.7 QUERY HYSTERESIS MIN
11.10 Special commands
25 Annex A (informative)Explanation of radiometric parameters of colour sensors
Figure A.1 – Example sensor sensitivity
26 Table A.1 – Example answers to QUERY COLOUR SENSOR (DTR0)
27 Bibliography
BS EN IEC 62386-305:2023
$142.49