BS EN 61347-2-9:2013
$167.15
Lamp controlgear – Particular requirements for electromagnetic controlgear for discharge lamps (excluding fluorescent lamps)
Published By | Publication Date | Number of Pages |
BSI | 2013 | 36 |
IEC 61347-2-9:2012 series specifies particular safety requirements for electromagnetic controlgear for discharge lamps such as high-pressure mercury vapour, low-pressure sodium vapour, high-pressure sodium vapour and metal halide lamps. The standard covers inductive-type electromagnetic controlgear for use on a.c. supplies up to 1 000 V at 50 Hz or 60 Hz, associated with discharge lamps, having rated wattages, dimensions and characteristics as specified in IEC 60188, IEC 60192 and IEC 60662. This second edition cancels and replaces the first edition published in 2000, Amendment 1:2003 and Amendment 2:2006. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) the addition of a new Clause 14; b) the word “ballast” is changed to “electromagnetic controlgear”. This publication is to be read in conjunction with /2.
PDF Catalog
PDF Pages | PDF Title |
---|---|
7 | English CONTENTS |
9 | INTRODUCTION |
10 | 1 Scope 2 Normative references 3 Terms and definitions |
11 | 4 General requirements 4.1 General 4.2 Capacitors and other components 4.3 Thermally protected electromagnetic controlgear 5 General notes on tests |
12 | 6 Classification 7 Marking 7.1 General 7.2 Mandatory markings 7.3 Information to be provided, if applicable 7.4 Other information |
13 | 8 Protection against accidental contact with live parts 9 Terminals 10 Provisions for earthing 11 Moisture resistance and insulation 12 Electric strength 13 Thermal endurance test for windings 14 Electromagnetic controlgear heating 14.1 General 14.2 Test requirements Table 1 – Test voltages for electromagnetic controlgear generating pulse voltages |
14 | 14.3 Normal operating condition 14.4 Abnormal operating condition |
15 | Table 2 – Maximum temperatures |
16 | Table 3 – Limiting temperatures of windings under abnormal operating conditions and at 110 % of rated voltage for electromagnetic controlgear subjected to endurance test duration of 30 days Table 4 – Limiting temperatures of windings under abnormal operating conditions and at 110 % of rated voltage for electromagnetic controlgear marked D6 which are subjected to an endurance test duration of 60 days |
17 | 15 High-voltage impulse testing 15.1 General 15.2 Test for electromagnetic controlgear operating with lamp with external starting devices 15.3 Test for electromagnetic controlgear operating with lamps with internal starting devices |
18 | Figure 1 – Test circuit for electromagnetic controlgear for lamps with integral starting devices |
19 | 16 Fault conditions 17 Construction 18 Creepage distances and clearances 19 Screws, current-carrying parts and connections 20 Resistance to heat, fire and tracking 21 Resistance to corrosion 22 No-load output voltage |
20 | Annex A (normative) Test to establish whether a conductive part is a live part which may cause an electric shock |
21 | Annex B (normative) Particular requirements for thermally protected lamp electromagnetic controlgear |
22 | Annex C (normative) Particular requirements for electronic lamp controlgear with means of protection against overheating |
23 | Annex D (normative) Requirements for carrying out the heating tests of thermally protected lamp electromagnetic controlgear |
24 | Annex E (normative) Use of constant S other than 4 500 in tw tests |
25 | Annex F (normative) Draught-proof enclosure |
26 | Annex G (normative) Explanation of the derivation of the values of pulse voltages |
27 | Annex H (normative) Tests |
28 | Annex I (normative) Method for selection of varistors I.1 General I.2 Selection of the varistors |
29 | Annex J (informative) Explanation of electromagnetic controlgear temperatures J.1 General J.2 Endurance |
30 | J.3 Electromagnetic controlgear heating J.4 Test arrangement |
31 | Figure J.1 – Test hood for electromagnetic controlgear heating test Figure J.2 – Test corner for electromagnetic controlgear heating |
32 | Annex K (normative) Additional requirements for built-in electromagnetic controlgear with double or reinforced insulation |
33 | Bibliography |