This part of IEC 60127 relates to special requirements applicable to cartridge fuse-links for miniature fuses with dimensions measuring 5 mm × 20 mm and 6,3 mm × 32 mm for the protection of electric appliances, electronic equipment and component parts thereof, normally intended for use indoors.

It does not apply to cartridge fuse-links for appliances intended to be used under special conditions, such as in corrosive or explosive atmospheres.

This standard applies in addition to the requirements of IEC 60127‑1 .

The object of this standard is to define special and additional test methods for cartridge fuse-links applying in addition to the requirements of IEC 60127‑1 .

PDF Catalog

PDF Pages PDF Title
6 English

CONTENTS
8 INTRODUCTION
9 1 Scope and object
2 Normative references
3 Terms and definitions
4 General requirements
5 Standard ratings
10 6 Marking
7 General notes on tests
11 Tables

Table 1 – Testing schedule for individual ampere ratings
Table 2 – Testing schedule for maximum ampere rating of a homogeneous series
12 Table 3 – Testing schedule for minimum ampere rating of a homogeneous series
13 Figures

Figure 1 – Test fuse-base for 5 mm x 20 mm and 6,3 mm x
32 mm fuse-links –Rated currents up to and including 6,3 A (see 7.3)
14 Figure 2 – Test fuse-base for 5 mm x 20 mm and 6,3 mm x
32 mm fuse-links –Rated currents exceeding 6,3 A (see 7.3)
15 Figure 3 – Test fuse-base for breaking capacity tests (see 7.3)
16 8 Dimensions and construction
17 Figure 4 – Axial pull test apparatus
18 9 Electrical requirements
Figure 5 – Alignment gauge (see 8.4)
19 Figure 6 – Typical test circuit for breaking-capacity tests for high-breaking capacity fuse-links (see 9.3)
Figure 7 – Typical test circuit for breaking-capacity tests for low- and enhanced-breaking capacity fuse-links (see 9.3)
20 10 Standard sheets
40 Annex A (normative) Miniature fuse-links with wire terminations
A.1 General
A.2 Scope
A.3 General notes on tests
A.3.1 Type tests
A.3.2 Testing schedule
41 A.3.3 Test bases for tests
Figure A.1 – Test board
Table A.1 – Testing schedule
42 Figure A.2 – Test base
43 A.4 Dimensions and construction
A.4.1 Dimensions
A.4.2 Mechanical tests on terminations
Figure A.3 – Dimensions of fuse-link with wire terminations
44 A.4.3 Solderability of terminations
A.4.4 Resistance to soldering heat
A.5 Electrical requirements
45 A.5.1 Voltage drop
A.5.2 Time/current characteristic at normal ambient temperature
A.5.3 Breaking capacity
A.5.4 Fuse-link temperature
46 Bibliography