BS EN 1999-1-4:2023

$215.11

Eurocode 9. Design of aluminium structures – Cold-formed structural sheeting

Published By Publication Date Number of Pages
BSI 2023 88
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

1.1 Scope of EN 1999-1-4 (1) EN 1999-1-4 gives design requirements for cold-formed trapezoidal aluminium sheeting. It applies to cold-formed aluminium products made from hot rolled or cold rolled sheet or strip that have been cold-formed by such processes as cold-rolled forming or press-breaking. NOTE 1 The rules in this part complement the rules in other parts of EN 1999-1. NOTE 2 The execution of aluminium structures made of cold-formed structures for roof, ceiling, floor and wall applications is covered in EN 1090-5. (2) EN 1999-1-4 gives methods for stressed-skin design using aluminium sheeting as a structural diaphragm. (3) EN 1999-1-4 does not apply to cold-formed aluminium profiles like C- and Z- profiles nor cold-formed and welded circular or rectangular hollow sections. (4) EN 1999-1-4 gives methods for design by calculation and for design assisted by testing. The methods for the design by calculation apply only within stated ranges of material properties and geometrical properties for which sufficient experience and test evidence is available. These limitations do not apply to design by testing. (5) EN 1999-1-4 does not cover load arrangement for loads during execution and maintenance. 1.2 Assumptions (1) For the design of new structures, EN 1999 is intended to be used, for direct application, together with EN 1990, EN 1991, EN 1992, EN 1993, EN 1994, EN 1995, EN 1997 and EN 1998. EN 1999 is intended to be used in conjunction with: – European Standards for construction products relevant for aluminium structures; – EN 1090-1, Execution of steel structures and aluminium structures – Part 1: Requirements for conformity assessment of structural components; – EN 1090-5, Execution of steel structures and aluminium structures – Part 5: Technical requirements for cold-formed structural aluminium elements and cold-formed structures for roof, ceiling, floor and wall applications.

PDF Catalog

PDF Pages PDF Title
2 undefined
12 1 Scope
2 Normative references
13 3 Terms, definitions and symbols
18 4 Basis of design
19 5 Materials
22 6 Durability
23 7 Structural analysis
40 8 Ultimate limit states
66 9 Serviceability limit states
67 10 Design of joints with mechanical fasteners
73 11 Design assisted by testing
74 Annex A (normative)Testing procedures
A.1 Use of this Annex
A.2 Scope and field of application
A.3 Tests on profiled sheets
A.3.1 General
75 A.3.2 Single span test
A.3.3 Double span test
A.3.4 Internal support test
78 A.3.5 End support test
A.4 Evaluation of test results
A.4.1 General
A.4.2 Adjustment of test results
79 A.4.3 Characteristic values
A.4.3.1 General
80 A.4.3.2 Characteristic values for families of tests
A.4.4 Design values
81 A.4.5 Serviceability
82 Annex B (informative)Durability of fasteners
B.1 Use of this Informative Annex
B.2 Scope and field of application
B.3 Fastener material with regard to corrosion environment
BS EN 1999-1-4:2023