Shopping Cart

No products in the cart.

BS EN 14511-3:2018

$198.66

Air conditioners, liquid chilling packages and heat pumps for space heating and cooling and process chillers, with electrically driven compressors – Test methods

Published By Publication Date Number of Pages
BSI 2018 56
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

1.1 Es gilt der Anwendungsbereich von EN 14511-1. 1.2 Diese Europäische Norm legt die Prüfverfahren für die Bemessung und Leistung von Luftkondi-tionierern, Flüssigkeitskühlsätzen und Wärmepumpen, die Luft, Wasser oder Sole als Wärmeträger nutzen und mit elektrisch angetriebenen Verdichtern betrieben werden, für die Raumbeheizung und -kühlung fest. Diese Prüfverfahren gelten auch für die Bemessung und Leistung von Prozess-Kühlern. Sie legt weiterhin ein Verfahren zur Prüfung und Angabe von Wärmerückgewinnungsleistungen, systemreduzierten Leistungen sowie der Leistung von Einzelgeräten von Multi-Split-Systemen für die Aufstellung im Innenraum, soweit zutreffend, fest. Diese Europäische Norm bietet außerdem die Möglichkeit, die Leistung von Multi-Split-Systemen und modularen Multi-Split-Systemen mit Wärmerückgewinnung durch getrennte Leistungsbemessung von Geräten für die Aufstellung im Innenraum und Geräten für die Außenaufstellung (Innen- und Außengeräte) zu bemessen.

PDF Catalog

PDF Pages PDF Title
2 National foreword
4 European foreword
European foreword
7 European foreword
8 1 Scope
2 Normative references
3 Terms and definitions
4 Tests for determination of capacities
4.1 Basic principles, method of calculation for the determination of capacities
4.1.1 Heating capacity
9 4.1.2 Cooling capacity
10 4.1.3 Heat recovery capacity
4.1.4 Capacity correction
12 4.1.5 Effective power input
14 4.1.6 Units on a distribution network of pressured water
4.1.7 Units for use with remote condenser
4.2 Test apparatus
4.2.1 Arrangement of the test apparatus
15 4.2.2 Installation and connection of the test object
16 4.3 Uncertainties of measurement
18 4.4 Test procedure
4.4.1 Settings
20 4.4.2 Output measurement for water (brine)-to-water (brine) and water (brine)-to-air units
21 4.4.3 Output measurement for cooling capacity of air-to-water (brine) and air-to-air units
4.4.4 Output measurement for heating capacity of air-to-air and air-to-water units
26 4.5 Test results
4.5.1 Data to be recorded
28 4.5.2 Cooling capacity and heat recovery capacity calculation
4.5.3 Heating capacity calculation
29 4.5.4 Effective power input calculation
5 Electrical consumptions for single duct and double duct units
5.1 Determination of power consumption due to standby mode
5.2 Determination of power consumption in off-mode
30 5.3 Electricity consumption
6 Air flow rate measurement of ducted units
7 Heat recovery test for air-cooled multisplit system
7.1 Test installation
7.1.1 General
7.1.2 Three-room calorimeter method
7.1.3 Three-room air-enthalpy method
7.1.4 Two-room air-enthalpy method
31 7.2 Test procedure
7.3 Test results
8 Test report
8.1 General information
8.2 Additional information
8.3 Rating test results
33 Annex A (normative) Calorimeter test method
41 Annex B (normative) Indoor air enthalpy test method
43 Annex C (informative) Conformance criteria
44 Annex D (informative) Symbols used in annexes
46 Annex E (informative) Test at system reduced capacity
47 Annex F (informative) Individual unit tests
48 Annex G (normative) Determination of the liquid pump efficiency
51 Annex H (informative) Rating of indoor and outdoor units of multisplit and modular heat recovery multisplit systems
53 Annex I (normative) Air flow rate measurement
54 Annex ZA (informative) Relationship between this European Standard and the requirements of Commission regulation (EC) No 206/2012 aimed to be covered
55 Bibliography
BS EN 14511-3:2018
$198.66